Harman Kardon HS 300 (serv.man3) EMC - CB Certificate ▷ View online

 
 
Report No. JSH006030124-001 
Page 32 of 81  
6.3 Test Protocol 
Temperature : 
20
°C  
Relative 
Humidity: 
45% 
 
 
Test Result: Pass 
Source qualification: Normal 
 
Current & voltage waveforms 
  
 
-0.3
-0.2
-0.1
0.0
0.1
0.2
0.3
-300
-200
-100
0
100
200
300
  
Current (Amps)
Voltage (Volts)
 
 
Harmonics and Class A limit line European 
Limits 
 
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
  
Current RMS(Amps)
Harmonic #
4
8
12
16
20
24
28
32
36
40
 
 
Test result:  Pass     Worst harmonic was #15 with 1.37% of the limit.  
                 
  
                 
  
 
 
Report No. JSH006030124-001 
Page 33 of 81  
Current Test Result Summary (Run time) 
 
 
Test Result: Pass 
Source qualification:  Normal 
THC(A): 0.03       I-THD(pk%): 18.22         POHC(A):  0.002        POHC Limit(A):  0.251          
Highest parameter values during test: 
V_RMS (Volts):   229.78 
Frequency(Hz):   50.00 
I_Peak (Amps):  0.281 
I_RMS (Amps):  0.161 
I_Fund (Amps):  0.158 
Crest Factor: 
1.771 
Power (Watts):   25.0 
Power Factor: 
0.678 
 
Harm# Harms(avg) 100%Limit %of Limit  Harms(max) 150%Limit %of 
Limit Status 
 
 
2  0.001 1.080  0.1 
0.001 1.620 0.07 
Pass 
 
3  0.026 2.300  1.1 
0.027 3.450 0.79 
Pass 
 
4  0.001 0.430  0.2 
0.001 0.645 0.12 
Pass 
 
5  0.006 1.140  0.5 
0.006 1.710 0.34 
Pass 
 
6  0.000 0.300  0.1 
0.001 0.450 0.11 
Pass 
 
7  0.002 0.770  0.3 
0.002 1.155 0.20 
Pass 
 
8  0.000 0.230  0.1 
0.000 0.345 0.07 
Pass 
 
9  0.002 0.400  0.4 
0.002 0.600 0.34 
Pass 
 
10  0.000 0.184  0.1 
0.000 0.276 0.09 
Pass 
 
11  0.001 0.330  0.4 
0.002 0.495 0.30 
Pass 
 
12  0.000 0.153  0.1 
0.000 0.230 0.11 
Pass 
 
13  0.003 0.210  1.5 
0.004 0.315 1.13 
Pass 
 
14  0.000 0.131  0.1 
0.000 0.197 0.10 
Pass 
 
15  0.003 0.150  1.9 
0.003 0.225 1.37 
Pass 
 
16  0.000 0.115  0.2 
0.000 0.173 0.19 
Pass 
 
17  0.002 0.132  1.4 
0.002 0.199 1.08 
Pass 
 
18  0.000 0.102  0.1 
0.000 0.153 0.12 
Pass 
 
19  0.001 0.118  0.7 
0.001 0.178 0.65 
Pass 
 
20  0.000 0.092  0.2 
0.000 0.138 0.22 
Pass 
 
21  0.001 0.107  0.7 
0.001 0.161 0.62 
Pass 
 
22  0.000 0.084  0.1 
0.000 0.125 0.11 
Pass 
 
23  0.001 0.098  0.7 
0.001 0.147 0.68 
Pass 
 
24  0.000 0.077  0.1 
0.000 0.115 0.12 
Pass 
 
25  0.001 0.090  1.2 
0.001 0.135 0.94 
Pass 
 
26  0.000 0.071  0.2 
0.000 0.106 0.16 
Pass 
 
27  0.000 0.083  0.4 
0.000 0.125 0.39 
Pass 
 
28  0.000 0.066  0.2 
0.000 0.099 0.17 
Pass 
 
29  0.001 0.078  1.0 
0.001 0.116 0.87 
Pass 
 
30  0.000 0.061  0.1 
0.000 0.092 0.14 
Pass 
 
31  0.001 0.073  1.2 
0.001 0.109 1.09 
Pass 
 
32  0.000 0.058  0.2 
0.000 0.086 0.16 
Pass 
 
33  0.000 0.068  0.7 
0.001 0.102 0.72 
Pass 
 
34  0.000 0.054  0.1 
0.000 0.081 0.13 
Pass 
 
35  0.000 0.064  0.7 
0.001 0.096 0.67 
Pass 
 
36  0.000 0.051  0.1 
0.000 0.077 0.13 
Pass 
 
37  0.000 0.061  0.5 
0.000 0.091 0.45 
Pass 
 
38  0.000 0.048  0.1 
0.000 0.073 0.13 
Pass 
 
39  0.000 0.058  0.2 
0.000 0.087 0.28 
Pass 
 
40  0.000 0.046  0.7 
0.000 0.069 0.59 
Pass 
 
 
 
Report No. JSH006030124-001 
Page 34 of 81  
6.4 Measurement Uncertainty  
 
The measurement uncertainty for harmonic test is under consideration according to CISPR 16- 
4:2002 
 
6.5 Additions, Deviations and Exclusions from Standards  
 
 None 
 
 
Report No. JSH006030124-001 
Page 35 of 81  
7. Voltage Fluctuations-Flicker 
 
Test result 
PASS 
 
7.1 Block Diagram of Test Setup 
 
   
     EUT 
Harmonic & flicker 
test system 
 
 
7.2 Test Setup and Test Procedure 
7.2.1 Definition 
 
Flicker:  
impression of unsteadiness of visual sensation induced by a lighting stimulus whose  
 
 
 
luminance or spectral distribution fluctuates with time. 
 
 
Pst:   
Short-term flicker indicator The flicker severity evaluated over a short period (in  
 
 
 
minutes); Pst=1 is the conventional  threshold of irritability  
 
Plt:   
long-term flicker indicator; the flicker severity evaluated over a long period (a few 
hous) 
 
 
 
Using successive Pst valuse. 
 
dc:   
the relative steady-state voltage change 
 
dmax: 
the maximum relative voltage change 
 
d(t):  
the value during a voltage change  
7.2.2  Photo For test Set-up 
 
none