Harman Kardon HS 200 (serv.man6) EMC - CB Certificate ▷ View online
Report No. JSH006110476-001
Page 56 of 69
15. Electric Fast Transient/Burst Immunity Test
Test result
PASS
15.1 Severity Level and Performance Criterion
15.1.1 Test level
Open circuit output test voltage(+/-10%) and repetition rate of the impulses (+/- 20%)
On power supply port PE
On I/O (input & output) signal,
data and control ports
Level
Voltage peak
kV
Repetition rate
kHz
Voltage peak
kV
Repetition rate
kHz
1 0.5 5 0.25 5
2
1
5
0.5 5
3 2 5 1 5
4 4
2.5
2 5
X
Special
Special
Special
Special
Notes : 1. “X” is a an open level. The level has to be specified in the dedicated equipment specification.
2. The gray rows were the selected test level.
15.1.2 Performance Criterion
Performance
criterion
B
Report No. JSH006110476-001
Page 57 of 69
15.2 Block Diagram of Test Setup
15.2 .1Test Setup and Test Procedure
Table top EUT
The EUT was placed on a 0.8m high wooded table, standing on the ground reference
plane 2.6m by 1.8m in size, made by aluminium 0.5mm thick.
The distance between the EUT and any other of the metallic surface except the GRP is
greater than 0.5m.
The main lead excess than 1m is gathered into a flat coil with a 0.4m diameter and situated
at a distance of 0.1m above the ground reference plane to insure the distance between the
coupling device and the EUT were 1m or less.
The EUT was arranged and connected to satisfy its functional requirement and supplied by
The coupling-decoupling network (Best EMC).
plane 2.6m by 1.8m in size, made by aluminium 0.5mm thick.
The distance between the EUT and any other of the metallic surface except the GRP is
greater than 0.5m.
The main lead excess than 1m is gathered into a flat coil with a 0.4m diameter and situated
at a distance of 0.1m above the ground reference plane to insure the distance between the
coupling device and the EUT were 1m or less.
The EUT was arranged and connected to satisfy its functional requirement and supplied by
The coupling-decoupling network (Best EMC).
Floor Standing EUT
The EUT was placed on a 0.1m high wooden support, standing on the ground reference
plane 2.6m by 1.8m, made by aluminium 0.5mm thick.
The distance between the EUT and any other of the metallic surface except the GRP is
greater than 0.5m.
The main lead excess than 1m is gathered into a flat coil with a 0.4m diameter and situated
at a distance of 0.1m above the ground reference plane to insure the distance between the
coupling device and the EUT were 1m or less.
The EUT was arranged and connected to satisfy its functional requirement and supplied by
The coupling-decoupling network (Best EMC).
plane 2.6m by 1.8m, made by aluminium 0.5mm thick.
The distance between the EUT and any other of the metallic surface except the GRP is
greater than 0.5m.
The main lead excess than 1m is gathered into a flat coil with a 0.4m diameter and situated
at a distance of 0.1m above the ground reference plane to insure the distance between the
coupling device and the EUT were 1m or less.
The EUT was arranged and connected to satisfy its functional requirement and supplied by
The coupling-decoupling network (Best EMC).
Best EMC
EUT
GRP
Report No. JSH006110476-001
Page 58 of 69
15.3 Test Protocol
Temperature :
23
°C
Relative Humidity:
34%
Test No.
#
Level
[kV]
Polarity
+/-
Line for test
Pass/
Fail
Comment
1 1 +/- L P
2 1 +/- N P
3 1 +/-
PE
NA
4 1 +/-
L-N
P
5 1 +/-
L-PE
NA
6 1 +/-
N-PE
NA
7 1 +/-
L,N.PE
NA
8 0.5 +/- DC -
9 0.5 +/- I/O -
15.4 Additions, Deviations and Exclusions from Standards
None.
Report No. JSH006110476-001
Page 59 of 69
16. Electromagnetic field susceptibility
Test result
Pass
16.1 Severity Level and Performance Criterion
16.1.1 Test level
Level
Test field strength V/m
1
1
2
3
3
10
X
Special
Note: 1. X is an open test level, this level may be given in the product specification.
2. The gray row is the selected test level.
16.1.2 Performance Criterion
Performance
criterion
A
Click on the first or last page to see other HS 200 (serv.man6) service manuals if exist.