Report No. JSH006110476-001 
Page 52 of 69 
 
14. Electrostatic Discharge (ESD) 
 
Test result 
PASS 
 
14.1 Severity Level and Performance Criterion 
14.1.1 Test level 
1a – Contact discharge 
 
1b – Air discharge 
Level 
 
Test voltage 
kV 
Level Test 
voltage 
 kV 
1 2 1 2 
2 4 
3 6 3 
4 8 4 15 
 X 
Special 
  X  
Special 
 
Notes: 1.“X” is an open level. The level has to be specified in the dedicated  
                equipment specification. If higher voltages than those shown are specified, special      
                test equipment may be needed. 
           2. The gray rows were the selected test level. 
 
 
14.1.2 Performance Criterion  
 
 Performance 
criterion 
B
 
 
 
Report No. JSH006110476-001 
Page 53 of 69 
 
14.2 Block Diagram of Test Setup 
 
 
 
Note:    HCP means Horizontal Coupling Plane, 
 VCP means Vertical Coupling Plane 
 GRP means Ground Reference Plane 
 
 
14.3 Test Setup and Test Procedure 
 
14.3.1 Test setup  
 
 
Tabletop EUT  
 
The EUT was put on a 0.8m high wooden tabel, standing on the ground reference  
plane(GRP) 2.6m by 1.8m in size, made by aluminium 0.5mm thick.  
 
A horizontal coupling plane(HCP) 1.6m by 0.8m in size was placed on the table, and  
the EUT with its cables were isolated from the HCP by an insulating support thick  
than 0.5mm. The VCP 0.5m by 0.5m in size & HCP were constructed from the same  
material type & thinkmess as that of the GRP, and connected to the GRP via a 470k
Ω  
resistor at each end. 
The distance between EUT and any of the other metallic surface excepted the GRP, HCP 
 & VCP was greater than 1m. 
 
The EUT was arranged and connected according to its functional requirements. 
 
    
Best EMC 
 
       EUT 
ESD simulator
  
VCP 
  
HCP 
Insulate  
Support
 
GRP 
470k
Ω 
Resist
o
 
Report No. JSH006110476-001 
Page 54 of 69 
 
       Floor standing EUT 
The EUT was put on a 0.1m high wooder support, standing on the ground reference  
plane(GRP) 2.6m by 1.8m, made by aluminuim 0.5mm thick. 
 
A vertical coupling plane (VCP) 0.5m by 0.5m in size, the same material type and thickness as that  
of  the ground reference plane was applied ,and was connected to the GRP via a 470k
Ω resistor at  
each end. 
 
The distance between EUT and any of the other metallic surface excepted the GRP, HCP & VCP  
was greater than 1m. 
 
The EUT was arranged and connected according to its functional requirements. 
14.3.2 Test Procedure 
 
The EUT was arranged and connected according to its functional requirements 
Direct static electricity discharges was applied only to those points and surface which are 
accessible to  
personnel during normal usage. 
The test voltage was increased from the minimum to the selected test level and with single 
discharge.  
On each preselected points 10 times of each polarity single discharge were applied  
The time interval between successive single discharges is 1s. 
The ESD generator was held perpendicular to the surface to which the discharge is applied. The  
discharge return cable of the generator was kept at a distance of 0.2m whilst the discharge is being  
applied. During the contact discharges, the tip of the discharge electrode was touch the EUT before  
the discharge switch is operated. During the air discharges, the round discharge tip of the discharge  
electrode was approached as fast as possible to touch the EUT. 
After each discharge, the ESD generator was removed from the EUT, the generator is then 
retriggered  
for a new single discharge.  
Indirect discharge was conducted to objects placed near the EUT, simulated by applying the 
dischares  
of the ESD generator to a coupling plane, in the contact discharge mode. 
10 times of each polarity single discharge were applied to HCP and VCP. The detail selected 
points are  
listed in the following table. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Report No. JSH006110476-001 
Page 55 of 69 
 
 
14.4 Test Protocol 
 
Temperature  : 
23
°C  
Relative Humidity: 
34% 
 
Direct discharge was applied at the following selected points: 
 
Test point 
Test level 
[kV] 
Air/ 
Contact 
Polarity 
(+/-) 
Pass/ 
Fail 
Comment 
Contact 
+/- 
All touchable screws of 
enclosure 
Contact 
+/- 
Accessible metal parts of the 
EUT 
Air 
+/- 
Air gap of the switch, button 
Air 
+/- 
The air in-taking opening 
Air 
+/- 
Slots around the EUT 
 
 
Indirect contact discharges were applied to the VCP and the HCP at the following selected points: 
 
Point Description 
Point 
Result 
HCP f 
0,1m from the front of the EUT 
Edge of centre,coner  on HCP 
HCP b 
0,1m from the back of the EUT 
Edge of centre,coner  on HCP 
HCP r 
0,1m from the right side of the EUT 
Edge of centre,coner  on HCP 
HCP l 
0,1m from the left side of the EUT 
Edge of centre,coner  on HCP 
VCP f 
0,1m from the front of the EUT 
Edge of centre,coner  on VCP 
VCP b 
0,1m from the back of the EUT 
Edge of centre,coner  on VCP 
VCP r 
0,1m from the right of the EUT 
Edge of centre,coner  on VCP 
VCP l 
0,1m from the left of the EUT 
Edge of centre,coner  on VCP 
 
14.5 Additions, Deviations and Exclusions from Standards 
 
 None
 