Harman Kardon HS 200 (serv.man6) EMC - CB Certificate ▷ View online
Report No. JSH006110476-001
Page 44 of 69
FM Mode
MAINS TERMINAL:
Report No. JSH006110476-001
Page 45 of 69
12. Immunity requirements for the enclosure port (S3)
12.1 Test result
Pass Fail Not Applicable
12.2 Operating environment
Temperature: 23
°C
Relative Humidity: 34 %
12.3 Test set-up
The stripline was placed on non-metallic supports 0.8m from the floor, and the top conductor
plate was no closer than 0.8m from the ceiling.
The equipment under test is placed on a non-metallic support 0.1m high, in the centre of the stripline in
the same position as for normal home usage.
Connecting leads to the equipment under test are inserted through holes in the base conductor plate of
the stripline, the length of the leads inside the stripline is as short as possible and completely
surrounded by ferrite rings to attenuate induced currents.
The mains lead is bundled to a length less than 30cm.
Terminals of the equipment under test not used during the measurement are terminated with shielded
resistors matching the nominal terminal impedance.
The equipment under test is placed on a non-metallic support 0.1m high, in the centre of the stripline in
the same position as for normal home usage.
Connecting leads to the equipment under test are inserted through holes in the base conductor plate of
the stripline, the length of the leads inside the stripline is as short as possible and completely
surrounded by ferrite rings to attenuate induced currents.
The mains lead is bundled to a length less than 30cm.
Terminals of the equipment under test not used during the measurement are terminated with shielded
resistors matching the nominal terminal impedance.
Report No. JSH006110476-001
Page 46 of 69
Report No. JSH006110476-001
Page 47 of 69
12.4 Test protocol
Pass
DVD Mode
DVD Mode
Click on the first or last page to see other HS 200 (serv.man6) service manuals if exist.