Harman Kardon HS 200 (serv.man4) EMC - CB Certificate ▷ View online
Page 8 of 64 Report No. JSH006110388-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
8.19.2
Mains switch ON indication
Not used as a disconnect
device
device
N/A
8.20
Switch not fitted in the mains cord
Pass
8.21
Bridging components comply with clause 14
N/A
9
ELECTRIC SHOCK HAZARD UNDER NORMAL OPERATING CONDITIONS
9.1
Testing on the outside
9.1.1
For voltages >1000 V ac or >1500 V dc complies
with clause 13.3.1 for basic insulation
with clause 13.3.1 for basic insulation
No such high voltage
N/A
9.1.1.1
Touch current measured from terminal devices
using the network in annex D .............................:
using the network in annex D .............................:
U1=10.3Vp
U2=0.30Vp
U2=0.30Vp
Pass
Discharge not exceeding 45 µC 1µC Pass
Energy of discharge not exceeding 350 mJ
No voltage exceeding 15Kv
N/A
9.1.1.2
Test with test finger and test probe
Pass
9.1.2
No hazardous live shafts of knobs, handles or
levers
levers
Pass
9.1.3
Ventilation holes and other holes tested by
means of 4 mm x 100 mm test pin
means of 4 mm x 100 mm test pin
2.3 mm max. no entering
N/A
9.1.4
Terminal devices tested with 1 mm x 20 mm test
pin (10 N); test probe D of IEC 61032
pin (10 N); test probe D of IEC 61032
Pass
Terminal devices tested with 1 mm x 100 mm
straight wire (1 N); test probe D of IEC 61032
straight wire (1 N); test probe D of IEC 61032
Pass
9.1.5
Pre-set controls tested with 2.5 mm x 100 mm
test pin (10 N); test probe C of IEC 61032
test pin (10 N); test probe C of IEC 61032
No pre-set control
N/A
9.1.6
No shock hazard due to stored charge on
withdrawal of the mains plug; voltage (V) after
2 s .....................................................................:
withdrawal of the mains plug; voltage (V) after
2 s .....................................................................:
< 5V
Pass
If C is not greater than 0,1 µF no test needed
> 0.1
µF N/A
9.1.7
Enclosure sufficiently resistant to external force
Pass
Test probe 11 of IEC 61032 for 10 s (50 N)
Pass
Test hook of fig. 4 for 10 s (20 N)
Pass
30 mm diameter test tool for 5 s (100 or 250 N) .: 100N Pass
9.2
No hazard after removing a cover by hand
Can not be removed by hand
N/A
Page 9 of 64 Report No. JSH006110388-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
10 INSULATION
REQUIREMENTS
10.1
Insulation resistance (MΩ) at least 2 MΩ min.
after surge test for basic and 4 MΩ min. for
reinforced insulation ...........................................:
after surge test for basic and 4 MΩ min. for
reinforced insulation ...........................................:
N/A
10.2
Humidity treatment 48 h or 120 h .......................: 48h, 30℃, 93%R.H.
Pass
10.3
Insulation resistance and dielectric strength
(See appended table)
Pass
11 FAULT
CONDITIONS
11.1
No shock hazard under fault condition
Pass
11.2
Heating under fault condition
(See appended table)
Pass
No hazard from softening solder
Pass
11.2.1
Measurement of temperature rises
Pass
11.2.2
Temperature rise of accessible parts
Pass
11.2.3
Temperature rise of parts, other than windings,
providing electrical insulation
providing electrical insulation
(See appended table)
Pass
Temperature rise of printed circuit boards (PCB)
exceeding the limits of table 3 by max. 100 K for
max. 5 min
exceeding the limits of table 3 by max. 100 K for
max. 5 min
N/A
a) Temperature rise of printed circuit boards
(PCB) to 20.1.3, exceeding the limits of table 3
by not more than 100 K for an area not greater
than 2 cm²
(PCB) to 20.1.3, exceeding the limits of table 3
by not more than 100 K for an area not greater
than 2 cm²
N/A
b) Temperature rise of printed circuit boards
(PCB) to 20.1.3 up to 300 K for an area not
greater than 2 cm² for a maximum of 5 min
(PCB) to 20.1.3 up to 300 K for an area not
greater than 2 cm² for a maximum of 5 min
N/A
Meets all the special conditions if conductors on
printed circuit boards are interrupted
printed circuit boards are interrupted
N/A
Class I protective earthing maintained
N/A
11.2.4
Temperature rise of parts acting as a support or
mechanical barrier
mechanical barrier
Pass
11.2.5
Temperature rise of windings
(see appended table)
Pass
11.2.6
Temperature rise of parts not subject to the limits
of 11.2.1 to 11.2.5
of 11.2.1 to 11.2.5
(see appended table)
Pass
12 MECHANICAL
STRENGTH
12.1.1
Bump test where mass >7 kg
3.9kg
N/A
Page 10 of 64 Report No. JSH006110388-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
12.1.2 Vibration
test
Not carried out, no connection
which might impair safety can
become loosen
which might impair safety can
become loosen
Pass
12.1.3
Impact hammer test
0.5J Pass
Steel ball test
2J Pass
12.1.4
Drop test for portable apparatus where mass < 7
kg
kg
Pass
12.1.5
Thermoplastic enclosures stress relief test
70
o
C, 7h
Pass
12.2
Fixing of knobs, push buttons, keys and levers
Pass
12.3
Remote controls with hazardous live parts
N/A
12.4
Drawers (pull test 50 N, 10 s)
N/A
12.5
Antenna coaxial sockets providing isolation
N/A
12.6
Telescoping or rod antennas construction
N/A
12.6.1
Telescoping or rod antennas securement
N/A
13
CLEARANCE AND CREEPAGE DISTANCES
13.1
Clearances in accordance with 13.3
Pass
Creepage distances in accordance with 13.4
Pass
13.2
Determination of operating voltage
T502: pin5- pin13: 398Vrms,
650Vp
T503: pin6 – pin16: 400Vrms,
640Vp
650Vp
T503: pin6 – pin16: 400Vrms,
640Vp
Pass
13.3
Clearances
(see appended table)
Pass
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table
9
comply with table 8 and, where applicable, table
9
Pass
13.3.3
Circuits not conductively connected to the mains
comply with table 10
comply with table 10
Such circuits are secondary
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
circuit and do not include
hazardous voltage, no basic,
supplementary or reinforced
insulation required.
N/A
13.4
Creepage distances
(see appended table)
Pass
Creepage distances greater than table 11 minima
Pass
13.5 Printed
boards
N/A
Page 11 of 64 Report No. JSH006110388-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of
which may be conductively connected to the
mains, as in fig. 10
conductors on printed circuit boards, one of
which may be conductively connected to the
mains, as in fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying
with IEC 60664-3 (basic insulation only)
with IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
comply with 8.8
N/A
13.7
Enclosed, enveloped or hermetically sealed
parts: not conductively connected to the mains:
clearances and creepage distances as in table 12
parts: not conductively connected to the mains:
clearances and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting
the requirements of 8.8
the requirements of 8.8
N/A
14 COMPONENTS
14.1 Resistors
a) Resistors between hazardous live parts and
accessible metal parts
accessible metal parts
R558 Pass
b) Resistors, other than between hazardous live
parts and accessible parts
parts and accessible parts
N/A
Resistors separately approved ...........................: R558 approved by VDE
Pass
14.2
Capacitors and RC units
Pass
Capacitors separately approved
Yes
Pass
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition : Y1: CY501, CY502, CY503,
CY504, CY505
Pass
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition : X2: CX501, CX502, CX503
Pass
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ..................:
connected to the mains: tests for X2 ..................:
No such component
N/A
14.2.5
Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better .................................................................:
where short-circuit current exceeds 0,2 A:
compliance with IEC60384-1, 4.38 category B or
better .................................................................:
Such capacitors with metal
cased
cased
N/A
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ....................................:
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60 384-1,
4.38 category B or better ....................................:
Such capacitors with metal
cased
cased
N/A
Shielded by a barrier to V-0 or metal ..................: N/A
Click on the first or last page to see other HS 200 (serv.man4) service manuals if exist.