Page 12 of 64 Report No. JSH006110388-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.3
Inductors and windings
Pass
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
(as relevant) and clause 20.1.4
N/A
14.3.1
Transformers and inductors marked with
manufacturer's name and type ...........................:
manufacturer's name and type ...........................:
Power transformer T502,
T503
T503
Line filter LF501, LF502
(See appended table14)
Pass
Transformers and inductors separately approved : No
N/A
14.3.2 General
Pass
14.3.3 Constructional
requirements
Pass
14.3.3.1
Clearances and creepage distances comply with
clause 13
clause 13
(see appended table)
Pass
14.3.3.2
Transformers meet the constructional
requirements
requirements
Pass
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible
parts (double or reinforced insulation)
between hazardous live parts and accessible
parts (double or reinforced insulation)
T502 basic insulation
minimum 7.0 mm between
T502 core and primary,
Supplementary insulation
minimum 4.8mm between
T502 core and secondary.
minimum 7.0 mm between
T502 core and primary,
Supplementary insulation
minimum 4.8mm between
T502 core and secondary.
T503 basic insulation
minimum 4.9 mm between
T503 core and primary,
Supplementary insulation
minimum 5.4mm between
T503 core and secondary.
minimum 4.9 mm between
T503 core and primary,
Supplementary insulation
minimum 5.4mm between
T503 core and secondary.
Pass
Coil formers and partition walls > 0,4 mm
T502 bobbin: 0.8mm min.
T503 bobbin: 0.8mm min.
Pass
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
protective screening only if all 7 conditions of
14.3.4.2 are met
Class II construction
N/A
14.3.4.3
Separating transformers with at least basic
insulation
insulation
N/A
Page 13 of 64 Report No. JSH006110388-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible
parts (double or reinforced insulation)
between hazardous live parts and accessible
parts (double or reinforced insulation)
T502 basic insulation
minimum 7.0 mm between
T502 core and primary,
Supplementary insulation
minimum 4.8mm between
T502 core and secondary.
minimum 7.0 mm between
T502 core and primary,
Supplementary insulation
minimum 4.8mm between
T502 core and secondary.
T503 basic insulation
minimum 4.9 mm between
T503 core and primary,
Supplementary insulation
minimum 5.4mm between
T503 core and secondary.
minimum 4.9 mm between
T503 core and primary,
Supplementary insulation
minimum 5.4mm between
T503 core and secondary.
Pass
Coil formers and partition walls > 0,4 mm
T502 bobbin: 0.8mm min.
T503 bobbin: 0.8mm min
Pass
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective
earth terminal
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective
earth terminal
Class II construction
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
adequate current-carrying capacity
N/A
14.4
High voltage components
No such components
N/A
High-voltage components and assemblies:
U > 4 kV (peak) separately approved
U > 4 kV (peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested
as part of the submission
as part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested
as part of the submission
as part of the submission
N/A
14.5 Protective
devices
Pass
Protective devices used within their ratings
Pass
External clearances and creepage distances
meet requirement of clause 13 for the voltage
across the device when opened
meet requirement of clause 13 for the voltage
across the device when opened
Fuse F501: 3.8mm
Pass
14.5.1.1
a) Thermal cut-outs separately approved
No such components
N/A
b) Thermal cut-outs tested as part of the
submission
submission
N/A
14.5.1.2
a) Thermal links separately approved
No such components
N/A
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
Page 14 of 64 Report No. JSH006110388-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
F501 approved.
Pass
14.5.2.2
Correct marking of fuse-links adjacent to holder .: F501: T3.15A L 250V
Pass
14.5.2.3
Not possible to connect fuses in parallel .............: Only one fuse holder
Pass
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool ......:
replacing fuse-links without the use of a tool ......:
Pass
14.5.3
PTC-S thermistors comply with IEC 60730-1
No such parts
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking
capacity and their position is correctly marked
capacity and their position is correctly marked
N/A
14.6 Switches
No
switch
N/A
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
V-0 compliance with annex G, G.1.1
N/A
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has
making/breaking action independent of speed of
actuation
61058-1 subclause 13.1 and has
making/breaking action independent of speed of
actuation
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not
attaining excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not
attaining excessive temperatures in use
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
N/A
Page 15 of 64 Report No. JSH006110388-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Socket outlet current marking correct
N/A
14.7
Safety interlocks
No such parts
N/A
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices
No such parts
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9 Motors
N/A
14.9.1
Endurance test on motors
Only low voltage DC servo
motor in DVD loader
motor in DVD loader
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-
phase motors and series motors meet
clause. B.8, B.9 and B.10 of IEC 60950, Annex B
phase motors and series motors meet
clause. B.8, B.9 and B.10 of IEC 60950, Annex B
N/A
14.10 Batteries
Pass
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
Only non-rechargeable alkali
batteries in IR remote
controller.
batteries in IR remote
controller.
Pass
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
No recharging circuit in
apparatus
apparatus
N/A
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
No recharging circuit in
apparatus
apparatus
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
No lithium battery
N/A
14.10.4
Battery mould stress relief
No such battery
N/A
14.10.5
Battery drop test
No such battery
N/A
14.11
Optocouplers
Separately approved, see
appended table
appended table
Pass
Optocouplers comply with Cl. 8
Internal DTI >0.40mm
Pass
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
alternatively 13.6 (jointed insulation)
int./ext. Cl. &Cr. >4mm /
≥6.0mm
Pass
14.12
Surge suppression varistors
VDE approved
Pass
Comply with IEC 61051-2
Pass