Harman Kardon HS 200 (serv.man4) EMC - CB Certificate ▷ View online
Page 24 of 64 Report No. JSH006110388-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Biblio-
graphy
graphy
Add
the following standards:
EN 50332-1:2000, Sound system equipment: Headphones and earphones
associated with portable audio equipment — Maximum sound pressure level
measurement methodology and limit considerations — Part 1: General method
for "one package equipment"
associated with portable audio equipment — Maximum sound pressure level
measurement methodology and limit considerations — Part 1: General method
for "one package equipment"
prEN 50332-2 (under consideration), Sound system
equipment: Headphones and earphones associated with portable audio
equipment — Maximum sound pressure level measurement methodology and
limit considerations — Part 2:
equipment — Maximum sound pressure level measurement methodology and
limit considerations — Part 2:
Guidelines to associate sets with headphones coming from different
manufacturers
manufacturers
N/A
Add
the following notes for the standards indicated:
IEC 60130
NOTE Parts 9 and 17:1998 are harmonized as ENs (not modified).
IEC 60169
NOTE Partly harmonized in the EN 60169/HD 134 series (not modified).
IEC 60173
NOTE Harmonized as HD 27 S1:1978 (not modified).
IEC 60335-2-56
NOTE Harmonized as EN 60335-2-56:1997 (not modified)
.
IEC 60335-2-82
NOTE Harmonized as EN 60335-2-82:2000 (not modified)
.
IEC 60695
NOTE Harmonized as EN 60695 series (not modified).
IEC 61040
NOTE Harmonized as EN 61040:1992 (not modified).
IEC 61558-2-1
NOTE Harmonized as EN 61558-2-1:1997 (not modified).
IEC 61558-2-4
NOTE Harmonized as EN 61558-2-4:1997 (not modified).
IEC 61558-2-6
NOTE Harmonized as EN 61558-2-6:1997 (not modified).
Pass
ZB
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
2.6.1
DK: certain types of Class I apparatus, see
15.1.1, may be provided with a plug not
establishing earthing continuity when inserted in
Danish socket-outlets
15.1.1, may be provided with a plug not
establishing earthing continuity when inserted in
Danish socket-outlets
Class II
N/A
13.3.1
NO: In Norway, due to IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230V in case of a single earth
fault.
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230V in case of a single earth
fault.
N/A
15.1.1
DK: mains cord for single-phase equipment
having a rated current not exceeding 10 A shall
be provided with a plug according to Heavy
Current Regulations Section 107-2-D1
having a rated current not exceeding 10 A shall
be provided with a plug according to Heavy
Current Regulations Section 107-2-D1
Pass
DK: Class I equipment with socket-outlets with
earthing contact, or which are intended to be
used in locations where protection against
indirect contact is required shall be provided with
a plug in compliance with Standard Sheet
DK 2-1a
earthing contact, or which are intended to be
used in locations where protection against
indirect contact is required shall be provided with
a plug in compliance with Standard Sheet
DK 2-1a
N/A
Page 25 of 64 Report No. JSH006110388-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
DK: socket-outlets for providing power to Class II
equipment with a rated current of 2,5 A shall
have dimensions according to the drawing on
page 131 of EN 60 065:98 other dimensions shall
be to IEC 60 083 Standard Sheet C 1a for
portable socket-outlets
equipment with a rated current of 2,5 A shall
have dimensions according to the drawing on
page 131 of EN 60 065:98 other dimensions shall
be to IEC 60 083 Standard Sheet C 1a for
portable socket-outlets
N/A
DK: mains socket-outlets with earthing contact
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
N/A
GB: equipment fitted with a flexible cable or cord
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
Pass
IE: equipment fitted with a flexible cable or cord
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
Pass
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the
following amendments:
following amendments:
N/A
- dimensions 2,5 A, 250 V socket-outlets shall
comply with Standard Sheet 1 page 132 of
EN 60 065:98
comply with Standard Sheet 1 page 132 of
EN 60 065:98
N/A
- mechanical strength 2,5 A, 250 V socket-outlets
tested as specified in EN 60 065, 12.1.3
tested as specified in EN 60 065, 12.1.3
N/A
- protecting rim also tested
N/A
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to
the public telecommunications network
reinforced insulation is required between parts
connected to the mains and parts connected to
the public telecommunications network
N/A
J.2
NO: In Norway, due to IT power distribution
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230V in case of a single earth
fault.
system used, the a.c. MAINS supply voltage is
considered to be equal to the line-to-line voltage,
and will remain 230V in case of a single earth
fault.
N/A
ZC
ANNEX ZC TO EN 60 065, A-DEVIATIONS
5
DE: additional markings required in German language:
- cathode ray tubes with an accelerating voltage
between 20 kV and 30 kV (marking on the tube)
between 20 kV and 30 kV (marking on the tube)
No CRT used.
N/A
- TV receivers whose picture tube has an
accelerating voltage between 20 kV and 30 kV
accelerating voltage between 20 kV and 30 kV
N/A
- TV receivers whose picture tube has an
accelerating voltage greater than 30 kV
accelerating voltage greater than 30 kV
N/A
Page 26 of 64 Report No. JSH006110388-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
- TV receivers whose picture tube has an
accelerating voltage less than 20 kV
accelerating voltage less than 20 kV
N/A
5.1
IT: additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
N/A
IT: user instructions in Italian language including
a conformity declaration
a conformity declaration
N/A
IT: certification number on the back cover
N/A
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
thermostats, relays and level controllers are not
allowed.
No such switch used.
N/A
Amendment 1 to EN60065, 7th edition
5.4.1
A warning that batteries (battery pack or batteries
installed) shall not be exposed to excessive heat
such as sunshine, fire or the like.
installed) shall not be exposed to excessive heat
such as sunshine, fire or the like.
N/A
Special stability warning for the apparatus with
CRT
CRT
Warning: the CRT in this product employs a
protective film on the face. This film must not be
removed as it serves a safety function and
removal will increase the risk of serious injury.
protective film on the face. This film must not be
removed as it serves a safety function and
removal will increase the risk of serious injury.
N/A
8.7 Void
N/A
8.8
For requirements for non-separable thin sheet
insulation in two or more layers, see 8.22.
insulation in two or more layers, see 8.22.
N/A
8.22
Requirements for non-separable thin sheet
insulation in two or more layers
insulation in two or more layers
N/A
15.2
Delete the paragraph: In supply apparatus of
Class I with non-hazardous live output voltage:
output circuit shall not be connected to the
protective earthing conductor.
Class I with non-hazardous live output voltage:
output circuit shall not be connected to the
protective earthing conductor.
N/A
18.1
Protective film as part of the implosion protection
system: all edges covered by the enclosure of
the apparatus
system: all edges covered by the enclosure of
the apparatus
N/A
19.3
100 N force, or 13% of weight, applied
horizontally to point of least stability.
horizontally to point of least stability.
N/A
20.1
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10
with openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10
with openings not exceeding 1 mm in width
Pass
b) Exemption for small components as defined in
20.1 excluding metal, glass and ceramic.
20.1 excluding metal, glass and ceramic.
Pass
Page 27 of 64 Report No. JSH006110388-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
5.1
TABLE: rated current/power consumption
Pass
Model
Input
voltage (V)
voltage (V)
Rated
current
(mA)
current
(mA)
Measured
current
(mA)
current
(mA)
Rated
power (W)
power (W)
Measured
power (W)
power (W)
condition/status
240 -
219 300 44.9
HS 200
100 -
447 300 44.2
Normal DVD playing
7.1
TABLE: temperature rise measurements
Pass
Power consumption in the OFF/Stand-by
0W/2.1W max.
—
Position of the functional switch (W) ..................:
On
—
Room temperature t1 (°C) ..................................:
24.0
Room temperature t2 (°C) ..................................:
24.0
Operating conditions
Normal DVD playing, with 1/8 non-clipped 400Hz sinusoidal output power to the speaker, operates 4 hours
until steady condition reached. Ambient 24
until steady condition reached. Ambient 24
o
C.
Un (V)
In (mA)
Pn (W)
Pout (V / mA)
264 216
45.1
N.A.
90 498
44.3
N.A.
Loudspeaker impedance (Ω) ..............................: 6Ω X 2
—
Several loudspeaker systems
2 channel speakers
Pass
Marking of loudspeaker terminals
Printed on rear enclosure
Pass
dT (K)
monitored point:
264
90
Permitted dT (K)
Power cord
20.5
22.8
60
Connector
18.6
22.3
-
Inlet 12.4
13.6
60
CX503 (X2 capacitor )
33.9
33.2
60 (85-25)
Winding of LF501
27.4
31.3
75*
PCB near BD501
38.6
37.0
85
Click on the first or last page to see other HS 200 (serv.man4) service manuals if exist.