Harman Kardon HS 200 (serv.man4) EMC - CB Certificate ▷ View online
Page 28 of 64 Report No. JSH006110388-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Operating conditions
PCB near Q509
45.5
37.7
85
CY502 (Y1 capacitor)
19.6
22.2
60 (85-25)
CY504 (Y1 capacitor)
40.9
38.4
60 (85-25)
CY505 (Y1 capacitor)
35.2
31.9
60 (85-25)
EC502 (electrolytic capacitor)
35.5
32.9
80 (105-25)
Winding of T502
46.3
43.5
75*
Bobbin of T502
44.8
42.2
75
PCB near T502
38.9
36.7
85
Winding of T503
40.6
40.2
75*
Bobbin of T503
40
39.6
75
PCB near T503
35.6
35.8
85
EC518 (electrolytic capacitor)
35.3
35.5
80 (105-25)
PCB near D515
37.0
38
85
PCB near D510
47.4
47.1
85
PCB of amplifier board
46.6
50
85
EC405 (electrolytic capacitor, on
amplifier board)
amplifier board)
40.8
43.8
80 (105-25)
Enclosure (metallic)
16.3
18.1
40
Enclosure (non-metallic) 12.8
12.9
60
winding temperature rise measurements:
Temperature rise dT of winding:
R1 (Ω) R2 (Ω) dT
(K) required
dT (K)
Insulation
class
class
10.3
TABLE: insulation resistance measurements
Pass
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
100
2
Between parts separated by basic or supplementary insulation
100
2
Between parts separated by double or reinforced insulation
4.3
4
Page 29 of 64 Report No. JSH006110388-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between parts of T502 separated by basic or supplementary
insulation
insulation
100 2
Between parts of T503 separated by basic or supplementary
insulation
insulation
100 2
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120Vp
No
Between parts separated by basic or supplementary insulation
2120Vp
No
Between parts separated by double or reinforced insulation
4240Vp
No
Between parts of T502 separated by basic or supplementary
insulation
insulation
2770Vp No
Between parts of T503 separated by basic or supplementary
insulation
insulation
2750Vp No
11.2
TABLE: summary of fault condition tests
Pass
Model/type of power supply ................................: --
—
Voltage (V) 0,9 or 1,1 times rated voltage ..........: 100-240
Ambient temperature (
o
C) ..................................: 24
—
No.
Component
No.
Fault
Test
voltage
(V)
Test
time
Fuse
No.
Fuse
current
(A)
Result
Dielectric
strength
test after
the test
1.
U502:
secondary
SC 264 2
min.
F501
0.07
P=2.4W max. Circuit
protected, no high
temperature, no hazard.
Recoverable after fault
removed.
protected, no high
temperature, no hazard.
Recoverable after fault
removed.
Pass
2.
R531 SC
264
2 min.
F501
0.07
P=2.3W max. Circuit
protected, no high
temperature, no hazard.
Recoverable after fault
removed.
protected, no high
temperature, no hazard.
Recoverable after fault
removed.
Pass
3.
D510
SC
264
5 min.
F501
0.15→
0.10
P=9.6W max. No high
temperature, no hazard.
Recoverable after fault
removed.
temperature, no hazard.
Recoverable after fault
removed.
Pass
Page 30 of 64 Report No. JSH006110388-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
4.
D512
SC
264
5 min.
F501
0.095→
0.08
P=4.6W max. No high
temperature, no hazard.
Recoverable after fault
removed.
temperature, no hazard.
Recoverable after fault
removed.
Pass
5.
D513 SC
264
2 min.
F501
0.08
P=5.2W max. Circuit
protected, no high
temperature, no hazard.
Recoverable after fault
removed.
protected, no high
temperature, no hazard.
Recoverable after fault
removed.
Pass
6.
D514
SC
264
5 min.
F501
0.097→
0.084
P=4.9W max. No high
temperature, no hazard.
Recoverable after fault
removed.
temperature, no hazard.
Recoverable after fault
removed.
Pass
7.
EC506
SC
264
5 min.
F501
0.216→
0.135
P=14.4W max. No extreme
high temperature, no
hazard. Recoverable after
fault removed.
high temperature, no
hazard. Recoverable after
fault removed.
Pass
8.
EC511
SC
264
5 min.
F501
0.15→
0.12
P=9.7W max. No extreme
high temperature, no
hazard. Recoverable after
fault removed.
high temperature, no
hazard. Recoverable after
fault removed.
Pass
9.
EC514
SC
264
5 min.
F501
0.12→
0.05
P=11.0W, 60s, D513
damaged, P=2.0W. No
extreme high temperature,
no hazard.
damaged, P=2.0W. No
extreme high temperature,
no hazard.
Pass
10.
EC516
SC
264
5 min.
F501
0.16→
0.12
P=9.4W max. No extreme
high temperature, no
hazard. Recoverable after
fault removed.
high temperature, no
hazard. Recoverable after
fault removed.
Pass
11.
U502:
primary
SC 264 2
min.
F501
0.061
P=0.9W max. Circuit
protected, no high
temperature, no hazard.
Recoverable after fault
removed.
protected, no high
temperature, no hazard.
Recoverable after fault
removed.
Pass
12.
EC501 SC
264
2 min.
F501
0.06
P=0.9W max. Circuit
protected, no high
temperature, no hazard.
Recoverable after fault
removed.
protected, no high
temperature, no hazard.
Recoverable after fault
removed.
Pass
13.
D503 SC
264
2 min.
F501
0.06
P=0.9W max. Circuit
protected, no high
temperature, no hazard.
Recoverable after fault
removed.
protected, no high
temperature, no hazard.
Recoverable after fault
removed.
Pass
14.
D504
SC
264
30 min. F501
0.264→
0.20→
0.07
P=59.7W, 5 min. P=22.5W
max. No extreme high
temperature, no hazard.
Recoverable after fault
removed. Monitored point:
PCB near Q501, 95
max. No extreme high
temperature, no hazard.
Recoverable after fault
removed. Monitored point:
PCB near Q501, 95
o
C
Pass
Page 31 of 64 Report No. JSH006110388-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
15.
U504:
secondary
SC 264
15
min. F501
0.157
P=16.8W, no extreme high
temperature, no hazard.
Recoverable after fault
removed.
temperature, no hazard.
Recoverable after fault
removed.
Pass
16.
U515:
secondary
SC 264 5
min.
F501
0.216
P=45.1W, as normal. No
high temperature, no
hazard. Recoverable after
fault removed.
high temperature, no
hazard. Recoverable after
fault removed.
Pass
17.
R543 SC
264
15 min. F501
0.143
P=18.0W, no extreme high
temperature, no hazard.
Recoverable after fault
removed.
temperature, no hazard.
Recoverable after fault
removed.
Pass
18.
U505:
secondary
SC 264
15
min. F501
0.143
P=18.1W, no extreme high
temperature, no hazard.
Recoverable after fault
removed.
temperature, no hazard.
Recoverable after fault
removed.
Pass
19.
U504:
primary
SC 264 5
min.
F501
0.216
P=45.1W, as normal. No
high temperature, no
hazard. Recoverable after
fault removed.
high temperature, no
hazard. Recoverable after
fault removed.
Pass
20.
U515:
primary
SC 264
15
min. F501
0.143
P=18.0W, no extreme high
temperature, no hazard.
Recoverable after fault
removed.
temperature, no hazard.
Recoverable after fault
removed.
Pass
21.
U505:
primary
SC 264
15
min. F501
0.143
P=17.9W, no extreme high
temperature, no hazard.
Recoverable after fault
removed.
temperature, no hazard.
Recoverable after fault
removed.
Pass
22.
EC503 SC
264
15 min. F501
0.165
P=17.7W, no extreme high
temperature, no hazard.
Recoverable after fault
removed.
temperature, no hazard.
Recoverable after fault
removed.
Pass
23.
D505
SC
264
30 min. F501
0.23→
0.18
P=50W, 5s, P=20.1W, R522
opened. No extreme high
temperature, no hazard.
opened. No extreme high
temperature, no hazard.
Pass
24.
D506 SC
264
5 min.
F501
0.216
P=45.1W, as normal. No
high temperature, no
hazard. Recoverable after
fault removed.
high temperature, no
hazard. Recoverable after
fault removed.
Pass
25.
R511
SC
264
30 min. F501
0.339
P=43.4W, PFC drop, no
extreme high temperature,
no hazard. Recoverable
after fault removed.
extreme high temperature,
no hazard. Recoverable
after fault removed.
Pass
26.
R588
SC
264
5 min.
F501
0.216
P=45.1W, as normal. No
high temperature, no
hazard. Recoverable after
fault removed.
high temperature, no
hazard. Recoverable after
fault removed.
Pass
27.
D508
SC
264
15 min. F501
0.146
P=17.0W, no extreme high
temperature, no hazard.
Recoverable after fault
removed.
temperature, no hazard.
Recoverable after fault
removed.