Page 28 of 64                        Report No. JSH006110388-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
Operating conditions 
PCB near Q509 
45.5
 
37.7
 
85 
CY502 (Y1 capacitor)  
19.6
 
22.2
 
60 (85-25) 
CY504 (Y1 capacitor)  
40.9
 
38.4
 
60 (85-25) 
CY505 (Y1 capacitor)  
35.2
 
31.9
 
60 (85-25) 
EC502 (electrolytic capacitor) 
35.5
 
32.9
 
80 (105-25) 
Winding of T502 
46.3
 
43.5
 
75* 
Bobbin of T502 
44.8
 
42.2
 
75 
PCB near T502 
38.9
 
36.7
 
85 
Winding of T503 
40.6
 
40.2
 
75* 
Bobbin of T503 
40
 
39.6
 
75 
PCB near T503 
35.6
 
35.8
 
85 
EC518 (electrolytic capacitor) 
35.3
 
35.5
 
80 (105-25) 
PCB near D515 
37.0
 
38
 
85 
PCB near D510 
47.4
 
47.1
 
85 
PCB of amplifier board 
46.6
 
50
 
85 
EC405 (electrolytic capacitor, on 
amplifier board) 
40.8
 
43.8
 
80 (105-25) 
Enclosure (metallic)  
16.3
 
18.1
 
40  
Enclosure (non-metallic) 12.8
 
12.9
 
60 
 
winding temperature rise measurements: 
 
Temperature rise dT of winding: 
R1 (Ω) R2 (Ω) dT 
(K)  required 
dT (K) 
Insulation 
class 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
10.3 
TABLE: insulation resistance measurements 
Pass 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between mains poles (primary fuse disconnected) 
100 
Between parts separated by basic or supplementary insulation
100 
Between parts separated by double or reinforced insulation 
4.3 
 
Page 29 of 64                        Report No. JSH006110388-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between parts of T502 separated by basic or supplementary 
insulation 
100 2 
Between parts of T503 separated by basic or supplementary 
insulation 
100 2 
 
 
10.3 
TABLE: electric strength measurements 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Mains poles (primary fuse disconnected) 
2120Vp 
No 
Between parts separated by basic or supplementary insulation
2120Vp 
No 
Between parts separated by double or reinforced insulation 
4240Vp 
No 
Between parts of T502 separated by basic or supplementary 
insulation 
2770Vp No 
Between parts of T503 separated by basic or supplementary 
insulation 
2750Vp No 
 
11.2 
TABLE: summary of fault condition tests 
Pass 
         
  Model/type of power supply ................................: -- 
— 
 
Voltage (V) 0,9 or 1,1 times rated voltage  ..........: 100-240 
 
         
  Ambient temperature (
o
C) ..................................: 24 
— 
 
No. 
Component 
No. 
Fault 
Test 
voltage 
(V) 
Test 
time 
Fuse 
No. 
Fuse 
current
(A) 
Result 
Dielectric 
strength 
test after 
the test
1.  
U502: 
secondary     
  
SC 264 2 
min.
F501
0.07 
P=2.4W max. Circuit 
protected, no high 
temperature, no hazard. 
Recoverable after fault 
removed. 
Pass 
2.   
R531         SC 
264 
2 min.
F501
0.07 
P=2.3W max. Circuit 
protected, no high 
temperature, no hazard. 
Recoverable after fault 
removed. 
Pass 
3.   
D510      
SC 
264 
5 min.
F501
0.15→
0.10 
P=9.6W max. No high 
temperature, no hazard. 
Recoverable after fault 
removed. 
Pass 
 
Page 30 of 64                        Report No. JSH006110388-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
4.   
D512      
SC 
264 
5 min.
F501
0.095→
0.08 
P=4.6W max. No high 
temperature, no hazard. 
Recoverable after fault 
removed. 
Pass 
5.   
D513         SC 
264 
2 min.
F501
0.08 
P=5.2W max. Circuit 
protected, no high 
temperature, no hazard. 
Recoverable after fault 
removed. 
Pass 
6.   
D514      
SC 
264 
5 min.
F501
0.097→
0.084 
P=4.9W max. No high 
temperature, no hazard. 
Recoverable after fault 
removed. 
Pass 
7.   
EC506   
SC 
264 
5 min.
F501
0.216→
0.135 
P=14.4W max. No extreme 
high temperature, no 
hazard. Recoverable after 
fault removed. 
Pass 
8.   
EC511  
SC 
264 
5 min.
F501
0.15→
0.12 
P=9.7W max. No extreme 
high temperature, no 
hazard. Recoverable after 
fault removed. 
Pass 
9.   
EC514  
SC 
264 
5 min.
F501
0.12→
0.05 
P=11.0W, 60s, D513 
damaged, P=2.0W. No 
extreme high temperature, 
no hazard. 
Pass 
10.  
EC516 
SC 
264 
5 min.
F501
0.16→
0.12 
P=9.4W max. No extreme 
high temperature, no 
hazard. Recoverable after 
fault removed. 
Pass 
11.  
U502:  
primary       
SC 264 2 
min.
F501
0.061 
P=0.9W max. Circuit 
protected, no high 
temperature, no hazard. 
Recoverable after fault 
removed. 
Pass 
12.  
EC501        SC 
264 
2 min.
F501
0.06 
P=0.9W max. Circuit 
protected, no high 
temperature, no hazard. 
Recoverable after fault 
removed. 
Pass 
13.  
D503         SC 
264 
2 min.
F501
0.06 
P=0.9W max. Circuit 
protected, no high 
temperature, no hazard. 
Recoverable after fault 
removed. 
Pass 
14.  
D504 
SC 
264 
30 min. F501
0.264→
0.20→
0.07 
P=59.7W, 5 min. P=22.5W 
max. No extreme high 
temperature, no hazard. 
Recoverable after fault 
removed. Monitored point: 
PCB near Q501, 95
o
Pass 
 
Page 31 of 64                        Report No. JSH006110388-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
15.  
U504: 
secondary     
  
SC 264 
15 
min. F501
0.157 
P=16.8W, no extreme high 
temperature, no hazard. 
Recoverable after fault 
removed. 
Pass 
16.  
U515: 
secondary     
  
SC 264 5 
min.
F501
0.216 
P=45.1W, as normal. No 
high temperature, no 
hazard. Recoverable after 
fault removed. 
Pass 
17.  
R543         SC 
264 
15 min. F501
0.143 
P=18.0W, no extreme high 
temperature, no hazard. 
Recoverable after fault 
removed. 
Pass 
18.  
U505: 
secondary     
  
SC 264 
15 
min. F501
0.143 
P=18.1W, no extreme high 
temperature, no hazard. 
Recoverable after fault 
removed. 
Pass 
19.  
U504:  
primary       
SC 264 5 
min.
F501
0.216 
P=45.1W, as normal. No 
high temperature, no 
hazard. Recoverable after 
fault removed. 
Pass 
20.  
U515:  
primary       
SC 264 
15 
min. F501
0.143 
P=18.0W, no extreme high 
temperature, no hazard. 
Recoverable after fault 
removed. 
Pass 
21.  
U505:  
primary       
SC 264 
15 
min. F501
0.143 
P=17.9W, no extreme high 
temperature, no hazard. 
Recoverable after fault 
removed. 
Pass 
22.  
EC503        SC 
264 
15 min. F501
0.165 
P=17.7W, no extreme high 
temperature, no hazard. 
Recoverable after fault 
removed. 
Pass 
23.  
D505 
SC 
264 
30 min. F501
0.23→
0.18 
P=50W, 5s, P=20.1W, R522 
opened. No extreme high 
temperature, no hazard.  
Pass 
24.  
D506         SC 
264 
5 min.
F501
0.216 
P=45.1W, as normal. No 
high temperature, no 
hazard. Recoverable after 
fault removed. 
Pass 
25.  
R511       
SC 
264 
30 min. F501
0.339 
P=43.4W, PFC drop, no 
extreme high temperature, 
no hazard. Recoverable 
after fault removed. 
Pass 
26.  
R588     
SC 
264 
5 min.
F501
0.216 
P=45.1W, as normal. No 
high temperature, no 
hazard. Recoverable after 
fault removed. 
Pass 
27.  
D508      
SC 
264 
15 min. F501
0.146 
P=17.0W, no extreme high 
temperature, no hazard. 
Recoverable after fault 
removed. 
Pass 