Harman Kardon HS 1000 (serv.man3) EMC - CB Certificate ▷ View online
Report No. SH09021130-001
Page 44 of 71
12.4 Test protocol
Pass
Report No. SH09021130-001
Page 45 of 71
13. Measurement of screening effectiveness (S4)
13.1 Test result
Pass Fail Not Applicable
13.2 Operating environment
Temperature: 22
°C
Relative Humidity: 43 %
13.3 Test set up
Report No. SH09021130-001
Page 46 of 71
13.4 Test protocol
Report No. SH09021130-001
Page 47 of 71
14. Electrostatic Discharge (ESD)
Test result
PASS
14.1 Severity Level and Performance Criterion
14.1.1 Test level
1a – Contact discharge
1b – Air discharge
Level
Test voltage
kV
Level Test
voltage
kV
1 2 1 2
2
4 2 4
3 6 3
8
4 8 4 15
X
Special
X
Special
Notes: 1.“X” is an open level. The level has to be specified in the dedicated
equipment specification. If higher voltages than those shown are specified, special
test equipment may be needed.
2. The gray rows were the selected test level.
14.1.2 Performance Criterion
Performance
criterion
B
Click on the first or last page to see other HS 1000 (serv.man3) service manuals if exist.