DOWNLOAD Harman Kardon HS 1000 (serv.man3) Service Manual ↓ Size: 4.22 MB | Pages: 72 in PDF or view online for FREE

Model
HS 1000 (serv.man3)
Pages
72
Size
4.22 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hs-1000-sm3.pdf
Date

Harman Kardon HS 1000 (serv.man3) EMC - CB Certificate ▷ View online

 
Report No. SH09021130-001 
Page 24 of 71 
 
5.4 Test Protocol 
 
Temperature  
22   
°C 
   
Relative Humidity 
43   % 
 
 
 
 
 
 
 
5.5 Measurement Uncertainty 
 
The measurement uncertainty describes the overall uncertainty of the given measured value   
during  the operation of the EUT. 
Measurement uncertainty is calculated in accordance with CISPR 16-4-2:2003 
 Measurement uncertainty of mains terminal disturbance power : 
±4.5dB 
The measurement uncertainty is given with a confidence of 95%, k=2 
 
5.6 Additions, Deviations and Exclusions from Standards  
 
 None 
 
 
 
Report No. SH09021130-001 
Page 25 of 71 
 
 
6. Harmonics 
 
Test   result: 
PASS 
 
 
6.1 Block Diagram of Test Setup 
 
 
 
 
 
 
 
 
6.2 Test Setup and Test Procedure 
 
Harmonics of the fundamental current were measured up to 40 order harmonics using a digital 
power  
meter with an analogue output and frequency analyser which was integrated in the harmonic & 
flicker  
test system. The measurements were carried out under steady conditions . 
 
 
The appliance has rated input power less than 75W, and is not luminaire, and according to the  
standards, no limit apply. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Harmonic & flicker 
test system 
     EUT 
 
Report No. SH09021130-001 
Page 26 of 71 
 
 
6.3 Test Protocol 
Temperature 
  : 25 
 
 
°C 
   
Relative Humidity 
 
50  % 
 
Current & voltage waveforms 
  
 
-0.6
-0.4
-0.2
0.0
0.2
0.4
0.6
-300
-200
-100
0
100
200
300
  
Current (Amps)
Voltage (Volts)
 
 
Harmonics and Class A limit line European 
Limits 
 
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
  
Current RMS(Amps)
Harmonic #
4
8
12
16
20
24
28
32
36
40
 
 
Test result:  Pass     Worst harmonic was #17 with 3.33% of the limit.  
                 
  
                 
  
 
Report No. SH09021130-001 
Page 27 of 71 
 
 
Current Test Result Summary (Run time) 
 
Test Result: Pass 
Source qualification:  Normal 
THC(A): 0.05       I-THD(pk%): 24.77         POHC(A):  0.005        POHC Limit(A):  0.251          
Highest parameter values during test: 
V_RMS (Volts):   229.71 
Frequency(Hz):   50.00 
I_Peak (Amps):  0.358 
I_RMS (Amps):  0.201 
I_Fund (Amps):  0.195 
Crest Factor: 
1.786 
Power (Watts):   36.7 
Power Factor: 
0.795 
 
Harm# Harms(avg) 100%Limit %of 
Limit  Harms(max) 150%Limit %of 
Limit Status 
 
 
2  0.001 1.080  0.1 
0.001 1.620  0.07 
Pass 
 
3  0.038 2.300  1.6 
0.042 3.450  1.23 
Pass 
 
4  0.001 0.430  0.1 
0.001 0.645  0.11 
Pass 
 
5  0.013 1.140  1.2 
0.015 1.710  0.87 
Pass 
 
6  0.001 0.300  0.2 
0.001 0.450  0.14 
Pass 
 
7  0.008 0.770  1.1 
0.009 1.155  0.80 
Pass 
 
8  0.000 0.230  0.1 
0.000 0.345  0.08 
Pass 
 
9  0.006 0.400  1.4 
0.006 0.600  1.05 
Pass 
 
10  0.000 0.184  0.1 
0.000 0.276  0.08 
Pass 
 
11  0.006 0.330  1.9 
0.007 0.495  1.37 
Pass 
 
12  0.000 0.153  0.1 
0.000 0.230  0.10 
Pass 
 
13  0.004 0.210  2.1 
0.005 0.315  1.60 
Pass 
 
14  0.000 0.131  0.1 
0.000 0.197  0.08 
Pass 
 
15  0.004 0.150  2.4 
0.004 0.225  1.83 
Pass 
 
16  0.000 0.115  0.2 
0.000 0.173  0.16 
Pass 
 
17  0.006 0.132  4.4 
0.007 0.199  3.33 
Pass 
 
18  0.000 0.102  0.1 
0.000 0.153  0.12 
Pass 
 
19  0.003 0.118  2.6 
0.004 0.178  2.03 
Pass 
 
20  0.000 0.092  0.1 
0.000 0.138  0.14 
Pass 
 
21  0.003 0.107  2.5 
0.003 0.161  2.08 
Pass 
 
22  0.000 0.084  0.1 
0.000 0.125  0.11 
Pass 
 
23  0.002 0.098  2.6 
0.003 0.147  2.17 
Pass 
 
24  0.000 0.077  0.2 
0.000 0.115  0.17 
Pass 
 
25  0.002 0.090  2.8 
0.003 0.135  2.10 
Pass 
 
26  0.000 0.071  0.2 
0.000 0.106  0.20 
Pass 
 
27  0.002 0.083  2.2 
0.002 0.125  1.98 
Pass 
 
28  0.000 0.066  0.2 
0.000 0.099  0.19 
Pass 
 
29  0.001 0.078  1.8 
0.002 0.116  1.66 
Pass 
 
30  0.000 0.061  0.2 
0.000 0.092  0.18 
Pass 
 
31  0.001 0.073  1.1 
0.001 0.109  0.99 
Pass 
 
32  0.000 0.058  0.3 
0.000 0.086  0.25 
Pass 
 
33  0.001 0.068  1.6 
0.001 0.102  1.37 
Pass 
 
34  0.000 0.054  0.2 
0.000 0.081  0.26 
Pass 
 
35  0.001 0.064  1.0 
0.001 0.096  0.83 
Pass 
 
36  0.000 0.051  0.3 
0.000 0.077  0.22 
Pass 
 
37  0.001 0.061  0.9 
0.001 0.091  0.76 
Pass 
 
38  0.000 0.048  0.2 
0.000 0.073  0.23 
Pass 
 
39  0.001 0.058  1.5 
0.001 0.087  1.23 
Pass 
 
40  0.000 0.046  0.6 
0.000 0.069  0.49 
Pass 
 
 
 
 
6.4 Measurement Uncertainty  
The measurement uncertainty for harmonic test is under consideration according to  
CISPR 16-4-2:2003 
 
6.5 Additions, Deviations and Exclusions from Standards  
 None 
Page of 72