                                                                   Page 26 of 65                               Report No. SH09051258-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
- TV receivers whose picture tube has an 
accelerating voltage less than 20 kV 
         
 N/A 
5.1 
IT: additional markings on the outside of the TV 
receiver in Italian language 
         
 N/A 
 
IT: user instructions in Italian language including a 
conformity declaration 
         
 N/A 
 
IT: certification number on the back cover 
         
 N/A 
14 
SE: Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed. 
No such switch used. 
Pass 
 
 
Amendment 1 to EN60065, 7th edition 
 
5.4.1 
A warning that batteries (battery pack or batteries 
installed) shall not be exposed to excessive heat 
such as sunshine, fire or the like. 
 N/A 
 
Special stability warning for the apparatus with 
CRT 
Warning: the CRT in this product employs a 
protective film on the face. This film must not be 
removed as it serves a safety function and removal 
will increase the risk of serious injury. 
 N/A 
8.7 Void 
 
N/A 
8.8 
For requirements for non-separable thin sheet 
insulation in two or more layers, see 8.22. 
 N/A 
8.22 
Requirements for non-separable thin sheet 
insulation in two or more layers 
 N/A 
15.2 
Delete the paragraph:  In supply apparatus of 
Class I with non-hazardous live output voltage: 
output circuit shall not be connected to the 
protective earthing conductor. 
 N/A 
18.1 
Protective film as part of the implosion protection 
system:  all edges covered by the enclosure of the 
apparatus 
 N/A 
19.3 
100 N force, or 13% of weight, applied horizontally 
to point of least stability. 
 N/A 
20.1 
a) Exemption for components contained in an 
enclosure of material V-0 to IEC 60695-11-10 with 
openings not exceeding 1 mm in width 
 Pass 
 
b) Exemption for small components as defined in 
20.1 excluding metal, glass and ceramic. 
 Pass 
 
                                                                   Page 27 of 65                               Report No. SH09051258-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
5.1 
TABLE: rated current/power consumption 
Pass 
 
Model  
Input voltage 
(V) 
Rated 
current 
(mA) 
Measured 
current 
(mA) 
Rated 
power (W) 
Measured 
power (W) 
condition/status 
240  - 
272 380 54.3 
HS 1000 
100  - 
563 380 55.1 
Normal DVD playing 
 
 
 
 
 
 
 
 
 
 
 
 
 
7.1 
TABLE: temperature rise measurements  
Pass 
 
Power consumption in the OFF/Stand-by 
0W/2.2W max. 
— 
 
Position of the functional switch (W) ...................... :
On 
— 
 
Room temperature t1 (°C)  ...................................:
17.5 
 
 
Room temperature t2 (°C)  ...................................:
17.5 
 
 
Operating conditions 
Normal DVD playing, with 1/8 non-clipped 400Hz sinusoidal output power to the speaker, operates 4 hours 
until steady condition reached.  
Un (V) 
In (mA)  
Pn (W)  
Pout (V / mA) 
264 258 
54.5 
N.A. 
90 630 
56.0 
N.A. 
 
         
 
Loudspeaker impedance (Ω) ................................. : 6 Ω X 5 
— 
         
 
Several loudspeaker systems 
5 channel speakers 
Pass 
         
 
Marking of loudspeaker terminals 
Printed on rear enclosure 
Pass 
dT (K) 
monitored point: 
264 
90 
Permitted dT (K) 
Connector(CN701) 21.9
 
27.1
 
CX703 (X2 capacitor ) 
24.3
 
30.2
 
60 (85-25) 
Winding of LF705 
25.9
 
30.7
 
75* 
CX702 (X2 capacitor ) 
30.8
 
34.3
 
60 (85-25) 
Winding of LF704 
26.6
 
29.8
 
75* 
PCB near BD701 
35.4
 
40.8
 
85 
PCB near Q703 
34.4
 
38.7
 
85 
Winding of LF703 
33.7
 
40.3
 
75* 
 
                                                                   Page 28 of 65                               Report No. SH09051258-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
Operating conditions 
CE702(electrolytic capacitor) 
36.3
 
39.3
 
80 (105-25) 
CY701(Y1 capacitor)  
40.2
 
42.1
 
60 (85-25) 
Winding of T702 
47.9
 
49.2
 
75* 
Bobbin of T702 
44.4
 
46.5
 
75 
PCB near T702 
43.3
 
44.2
 
85 
Winding of T701 
40.0
 
40.5
 
75* 
Bobbin of T701 
36.6
 
37.9
 
75 
PCB near T701 
32.8
 
33.1
 
85 
PCB near D710 
40.5
 
40.5
 
85 
Power cord 
17.5
 
21.9
 
60  
PCB near U204 
56.7
 
56.5
 
85 
PCB near U422 
54.2
 
54.1
 
85 
PCB near U412 
64.8
 
64.3
 
85 
PCB near U421 
51.2
 
51.4
 
85 
PCB near U404 
63.4
 
63.4
 
85 
PCB near U406 
65.1
 
64.9
 
85 
PCB near U407 
51.3
 
51.0
 
85 
PCB near U410 
52.1
 
51.7
 
85 
PCB near U413 
52.2
 
52.4
 
85 
Enclosure (metallic)  
20.3
 
20.6
 
40  
Enclosure (non-metallic) 
16.5
 
15.9
 
60 
 
winding temperature rise measurements: 
 
Temperature rise dT of winding: 
R1 (Ω) R2 (Ω) 
dT (K) 
required 
dT (K) 
Insulation 
class 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                                                                   Page 29 of 65                               Report No. SH09051258-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
     TRF originator Intertek ETL SEMKO SH 
 
 
10.3 
TABLE: insulation resistance measurements 
Pass 
 
Insulation resistance R between: 
R (MΩ) 
Required R (MΩ) 
Between mains poles (primary fuse disconnected) 
100 
Between parts separated by basic or supplementary insulation 
100 
Between parts separated by double or reinforced insulation 
20.6 
Between parts of T701 separated by basic or supplementary 
insulation 
100 2 
Between parts of T702 separated by basic or supplementary 
insulation 
100 2 
 
 
10.3 
TABLE: electric strength measurements 
 
Test voltage applied between: 
Test voltage (V) 
Breakdown 
Mains poles (primary fuse disconnected) 
2120Vp 
No 
Between parts separated by basic or supplementary insulation 
2120Vp 
No 
Between parts separated by double or reinforced insulation 
4240Vp 
No 
Between parts of T701 separated by basic or supplementary 
insulation 
2454Vp No 
Between parts of T702 separated by basic or supplementary 
insulation 
2520Vp No 
 
11.2 
TABLE: summary of fault condition tests 
Pass 
         
  Model/type of power supply  .................................: -- 
— 
 
Voltage (V) 0,9 or 1,1 times rated voltage  ............. : 100-240 
 
         
  Ambient temperature (
o
C) ...................................... : 24 
— 
 
No. 
Component 
No. 
Fault 
Test 
voltage 
(V) 
Test 
time 
Fuse 
No. 
Fuse 
current
(A) 
Result 
Dielectric 
strength 
test after 
the test
1.  
U711: 
secondary     
  
SC 264 5 
min.
F702
0.069 
P=1.3W. No high 
temperature, no hazard.  
Pass 
2.   
D725          SC 
264 
5 min.
F702
0.069 
P=1.3W. No high 
temperature, no hazard.  
Pass 
3.   
CE727         SC 
264 
15 min.
F702
0.18→
0.07 
P=13.5W max. No high 
temperature, no hazard.  
Pass 
4.   
D722        
SC 
264 
15 min.
F702
0.113 
P=10.5W. No high 
temperature, no hazard.  
Pass 
Page of 68