Page 26 of 65 Report No. SH09051258-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
- TV receivers whose picture tube has an
accelerating voltage less than 20 kV
accelerating voltage less than 20 kV
N/A
5.1
IT: additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
N/A
IT: user instructions in Italian language including a
conformity declaration
conformity declaration
N/A
IT: certification number on the back cover
N/A
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
thermostats, relays and level controllers are not
allowed.
No such switch used.
Pass
Amendment 1 to EN60065, 7th edition
5.4.1
A warning that batteries (battery pack or batteries
installed) shall not be exposed to excessive heat
such as sunshine, fire or the like.
installed) shall not be exposed to excessive heat
such as sunshine, fire or the like.
N/A
Special stability warning for the apparatus with
CRT
CRT
Warning: the CRT in this product employs a
protective film on the face. This film must not be
removed as it serves a safety function and removal
will increase the risk of serious injury.
protective film on the face. This film must not be
removed as it serves a safety function and removal
will increase the risk of serious injury.
N/A
8.7 Void
N/A
8.8
For requirements for non-separable thin sheet
insulation in two or more layers, see 8.22.
insulation in two or more layers, see 8.22.
N/A
8.22
Requirements for non-separable thin sheet
insulation in two or more layers
insulation in two or more layers
N/A
15.2
Delete the paragraph: In supply apparatus of
Class I with non-hazardous live output voltage:
output circuit shall not be connected to the
protective earthing conductor.
Class I with non-hazardous live output voltage:
output circuit shall not be connected to the
protective earthing conductor.
N/A
18.1
Protective film as part of the implosion protection
system: all edges covered by the enclosure of the
apparatus
system: all edges covered by the enclosure of the
apparatus
N/A
19.3
100 N force, or 13% of weight, applied horizontally
to point of least stability.
to point of least stability.
N/A
20.1
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
Pass
b) Exemption for small components as defined in
20.1 excluding metal, glass and ceramic.
20.1 excluding metal, glass and ceramic.
Pass
Page 27 of 65 Report No. SH09051258-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
5.1
TABLE: rated current/power consumption
Pass
Model
Input voltage
(V)
(V)
Rated
current
(mA)
current
(mA)
Measured
current
(mA)
current
(mA)
Rated
power (W)
power (W)
Measured
power (W)
power (W)
condition/status
240 -
272 380 54.3
HS 1000
100 -
563 380 55.1
Normal DVD playing
7.1
TABLE: temperature rise measurements
Pass
Power consumption in the OFF/Stand-by
0W/2.2W max.
—
Position of the functional switch (W) ...................... :
On
—
Room temperature t1 (°C) ...................................:
17.5
Room temperature t2 (°C) ...................................:
17.5
Operating conditions
Normal DVD playing, with 1/8 non-clipped 400Hz sinusoidal output power to the speaker, operates 4 hours
until steady condition reached.
until steady condition reached.
Un (V)
In (mA)
Pn (W)
Pout (V / mA)
264 258
54.5
N.A.
90 630
56.0
N.A.
Loudspeaker impedance (Ω) ................................. : 6 Ω X 5
—
Several loudspeaker systems
5 channel speakers
Pass
Marking of loudspeaker terminals
Printed on rear enclosure
Pass
dT (K)
monitored point:
264
90
Permitted dT (K)
Connector(CN701) 21.9
27.1
-
CX703 (X2 capacitor )
24.3
30.2
60 (85-25)
Winding of LF705
25.9
30.7
75*
CX702 (X2 capacitor )
30.8
34.3
60 (85-25)
Winding of LF704
26.6
29.8
75*
PCB near BD701
35.4
40.8
85
PCB near Q703
34.4
38.7
85
Winding of LF703
33.7
40.3
75*
Page 28 of 65 Report No. SH09051258-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
Operating conditions
CE702(electrolytic capacitor)
36.3
39.3
80 (105-25)
CY701(Y1 capacitor)
40.2
42.1
60 (85-25)
Winding of T702
47.9
49.2
75*
Bobbin of T702
44.4
46.5
75
PCB near T702
43.3
44.2
85
Winding of T701
40.0
40.5
75*
Bobbin of T701
36.6
37.9
75
PCB near T701
32.8
33.1
85
PCB near D710
40.5
40.5
85
Power cord
17.5
21.9
60
PCB near U204
56.7
56.5
85
PCB near U422
54.2
54.1
85
PCB near U412
64.8
64.3
85
PCB near U421
51.2
51.4
85
PCB near U404
63.4
63.4
85
PCB near U406
65.1
64.9
85
PCB near U407
51.3
51.0
85
PCB near U410
52.1
51.7
85
PCB near U413
52.2
52.4
85
Enclosure (metallic)
20.3
20.6
40
Enclosure (non-metallic)
16.5
15.9
60
winding temperature rise measurements:
Temperature rise dT of winding:
R1 (Ω) R2 (Ω)
dT (K)
required
dT (K)
dT (K)
Insulation
class
class
Page 29 of 65 Report No. SH09051258-001
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No: IEC/EN 60065H
TRF originator Intertek ETL SEMKO SH
10.3
TABLE: insulation resistance measurements
Pass
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
100
2
Between parts separated by basic or supplementary insulation
100
2
Between parts separated by double or reinforced insulation
20.6
4
Between parts of T701 separated by basic or supplementary
insulation
insulation
100 2
Between parts of T702 separated by basic or supplementary
insulation
insulation
100 2
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
2120Vp
No
Between parts separated by basic or supplementary insulation
2120Vp
No
Between parts separated by double or reinforced insulation
4240Vp
No
Between parts of T701 separated by basic or supplementary
insulation
insulation
2454Vp No
Between parts of T702 separated by basic or supplementary
insulation
insulation
2520Vp No
11.2
TABLE: summary of fault condition tests
Pass
Model/type of power supply .................................: --
—
Voltage (V) 0,9 or 1,1 times rated voltage ............. : 100-240
Ambient temperature (
o
C) ...................................... : 24
—
No.
Component
No.
Fault
Test
voltage
(V)
Test
time
Fuse
No.
Fuse
current
(A)
Result
Dielectric
strength
test after
the test
1.
U711:
secondary
SC 264 5
min.
F702
0.069
P=1.3W. No high
temperature, no hazard.
temperature, no hazard.
Pass
2.
D725 SC
264
5 min.
F702
0.069
P=1.3W. No high
temperature, no hazard.
temperature, no hazard.
Pass
3.
CE727 SC
264
15 min.
F702
0.18→
0.07
P=13.5W max. No high
temperature, no hazard.
temperature, no hazard.
Pass
4.
D722
SC
264
15 min.
F702
0.113
P=10.5W. No high
temperature, no hazard.
temperature, no hazard.
Pass