                                                                   Page 22 of 65                               Report No. SH09051258-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
CENELEC COMMON MODIFICATIONS [C], SPECIAL NATIONAL CONDITIONS [S] AND 
A-DEVIATIONS (NATIONAL DEVIATIONS) [A] (EN 60065:2002) 
 
3.1 
Add 
the following indent at the end of the list: 
- exposure to excessive sound pressures from 
headphones or earphones. 
 
NOTE A new method of measurement is described in EN 
50332-1, Sound system equipment: 
Headphones and earphones associated with portable audio 
equipment - Maximum sound pressurelevel measurement 
methodology and limit considerations - Part 1: General 
method for "one package equipment”, and in EN 50332-2, 
Sound system equipment: Headphones and earphones 
associated with portable audio equipment - Maximum sound 
pressure level measurement methodology and limit 
considerations - Part 2: Guidelines to associate sets with 
headphones coming from different manufacturers. 
 N/A 
4.1.1 
Replace 
the text of the note by: 
 
NOTE For ROUTINE TEST reference is made to EN 50333. 
 N/A 
5.1.i) 
Add 
the following note: 
 
NOTE For RATED POWER CONSUMPTION measurements 
of TVs reference is made to 
EN 60107. 
 N/A 
6.1 
Replace 
the entire subclause by: 
Apparatus including a potential source of ionizing 
radiation shall be so constructed that personal 
protection against ionizing radiation is provided 
under normal operating conditions and under 
fault conditions. 
 
Compliance is checked by measurement under 
the following conditions
In addition to the normal operating conditions, all 
controls adjustable from the outside BY HAND, 
by any object such as a tool or a coin, and those 
internal adjustments or pre-sets which are not 
locked in a reliable manner, are adjusted so as to 
give maximum radiation whilst maintaining an 
intelligible picture for 1 h, at the end of which the 
measurement is made. 
 
NOTE Soldered joints and paint lockings are examples of 
adequate locking. 
 N/A 
 
                                                                   Page 23 of 65                               Report No. SH09051258-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
6.1 
(Cont) 
The amount of ionizing radiation is regulated by 
European Council Directive 96/29/Euratom of 13 
May 1996. This directive requires that at any 
point 10 cm from the outer surface of the 
apparatus, the dose-rate shall not exceed 
1µSv/h (0,1 mR/h) taking account of the 
background level. 
Moreover, the measurement shall be made under 
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is 
maintained for 1 h, at the end of which the 
measurement is made. 
A picture is considered to be intelligible if the 
following conditions are met: 
- a scanning amplitude of at least 70 % of the 
usable screen width; 
- a minimum luminance of 50 cd/m² with locked 
blank raster provided by a test generator; 
- a horizontal resolution corresponding to at least 
1,5 MHz in the centre, with a similar vertical 
degradation; 
- not more than one flashover per 5 min. 
 N/A 
13.3.1 Delete 
note 4. 
 
Pass 
14 
Delete note 4 and note 5. 
 
Pass 
15.1.1 
Delete note 1 and note 2. 
 
Pass 
15.2 Delete 
note 2. 
 
Pass 
16.1 Delete 
note 1. 
 
Pass 
16.2 Delete 
the note. 
 
Pass 
20 
Delete note 2. 
 
Pass 
Annex B 
Replace note 1 by: 
In the CENELEC countries listed in IEC 62151, 
special national conditions apply. 
 N/A 
 
Annex G 
Delete the note. 
 
N/A 
Annex J.2  Delete the notes of Table J.1 
 
N/A  
Annex N 
Add after the introduction: 
For ROUTINE TEST reference is made to EN 
50333. 
 N/A 
 
                                                                   Page 24 of 65                               Report No. SH09051258-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
Biblio-
graphy 
Add 
the following standards: 
EN 50332-1:2000, Sound system equipment: Headphones and earphones 
associated with portable audio equipment — Maximum sound pressure level 
measurement methodology and limit considerations — Part 1: General method 
for "one package equipment" 
prEN 50332-2 (under consideration), Sound system 
equipment: Headphones and earphones associated with portable audio 
equipment — Maximum sound pressure level measurement methodology and 
limit considerations — Part 2: 
Guidelines to associate sets with headphones coming from different 
manufacturers
 
N/A  
 
Add 
the following notes for the standards indicated: 
IEC 60130 
NOTE Parts 9 and 17:1998 are harmonized as ENs (not modified). 
IEC 60169 
NOTE Partly harmonized in the EN 60169/HD 134 series (not modified). 
IEC 60173 
NOTE Harmonized as HD 27 S1:1978 (not modified). 
IEC 60335-2-56 
NOTE Harmonized as EN 60335-2-56:1997 (not modified)
IEC 60335-2-82 
NOTE Harmonized as EN 60335-2-82:2000 (not modified)
IEC 60695 
NOTE Harmonized as EN 60695 series (not modified). 
IEC 61040 
NOTE Harmonized as EN 61040:1992 (not modified). 
IEC 61558-2-1 
NOTE Harmonized as EN 61558-2-1:1997 (not modified). 
IEC 61558-2-4 
NOTE Harmonized as EN 61558-2-4:1997 (not modified). 
IEC 61558-2-6 
NOTE Harmonized as EN 61558-2-6:1997 (not modified).
 
Pass  
 
 
ZB 
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS 
 
2.6.1 
DK: certain types of Class I apparatus, see 15.1.1, 
may be provided with a plug not establishing 
earthing continuity when inserted in Danish socket-
outlets 
Class II 
N/A 
13.3.1 
NO: In Norway, due to IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230V in case of a single earth fault. 
 Pass 
15.1.1 
DK: mains cord for single-phase equipment having 
a rated current not exceeding 10 A shall be 
provided with a plug according to Heavy Current 
Regulations Section 107-2-D1 
         
 Pass 
 
DK: Class I equipment with socket-outlets with 
earthing contact, or which are intended to be used 
in locations where protection against indirect 
contact is required shall be provided with a plug in 
compliance with Standard Sheet DK 2-1a 
         
 N/A 
 
                                                                   Page 25 of 65                               Report No. SH09051258-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
DK: socket-outlets for providing power to Class II 
equipment with a  rated current of 2,5 A shall have 
dimensions according to the drawing on page 131 
of EN 60 065:98 other dimensions shall be to 
IEC 60 083 Standard Sheet C 1a for portable 
socket-outlets 
         
 N/A 
 
DK: mains socket-outlets with earthing contact 
shall comply with Heavy Current Regulations 
Section 107-2-D1, Standard Sheet DK 1-3a, 
DK 1-5a or DK 1-7a 
         
 N/A 
 
GB: equipment fitted with a flexible cable or cord 
provided with a 13A BS 1363 plug as in Statutory 
Instrument 1768:94 
 Pass 
 
IE: equipment fitted with a flexible cable or cord 
provided with a 13 A plug in accordance with 
Statutory Instrument 525:97 
         
 Pass 
 
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the 
following amendments: 
N/A 
 
- dimensions 2,5 A, 250 V socket-outlets shall 
comply with Standard Sheet 1 page 132 of 
EN 60 065:98 
         
 N/A 
 
- mechanical strength 2,5 A, 250 V socket-outlets 
tested as specified in EN 60 065, 12.1.3 
         
 N/A 
 
- protecting rim also tested 
         
 N/A 
 
NO: method b) of 8.1 is not permitted. Double or 
reinforced insulation is required between parts 
connected to the mains and parts connected to the 
public telecommunications network 
         
 N/A 
J.2 
NO: In Norway, due to IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230V in case of a single earth fault. 
 Pass 
 
 
ZC 
ANNEX ZC TO EN 60 065, A-DEVIATIONS 
 
DE: additional markings required in German language: 
 
 
- cathode ray tubes with an accelerating voltage 
between 20 kV and 30 kV (marking on the tube) 
No CRT used. 
N/A 
 
- TV receivers whose picture tube has an 
accelerating voltage between 20 kV and 30 kV 
         
 N/A 
 
- TV receivers whose picture tube has an 
accelerating voltage greater than 30 kV 
         
 N/A 
Page of 68