DOWNLOAD Harman Kardon HS 1000 (serv.man2) Service Manual ↓ Size: 4.97 MB | Pages: 68 in PDF or view online for FREE

Model
HS 1000 (serv.man2)
Pages
68
Size
4.97 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hs-1000-sm2.pdf
Date

Harman Kardon HS 1000 (serv.man2) EMC - CB Certificate ▷ View online

 
                                                                   Page 10 of 65                               Report No. SH09051258-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
12.1.5 
Thermoplastic enclosures stress relief test 
70
o
C, 7h 
Pass 
12.2 
Fixing of knobs, push buttons, keys and levers 
 
Pass 
12.3 Remote 
controls with hazardous live parts 
         
 
N/A 
12.4 
Drawers (pull test 50 N, 10 s) 
         
 
N/A 
12.5 
Antenna coaxial sockets providing isolation 
         
 
N/A 
12.6 
Telescoping or rod antennas construction 
 
N/A 
12.6.1 
Telescoping or rod antennas securement 
 
N/A 
 
 
13 
CLEARANCE AND CREEPAGE DISTANCES 
 
13.1 
Clearances in accordance with 13.3 
 
Pass 
 
Creepage distances in accordance with 13.4 
 
Pass 
13.2 
Determination of operating voltage 
T701: 230Vrms, 550Vp 
T702: 380Vrms, 530Vp 
CY701: 350Vrms, 408Vp 
Pass 
13.3 
Clearances 
(see appended table) 
Pass 
13.3.2 
Circuits conductively connected to the mains 
comply with table 8 and, where applicable, table 9
 
Pass 
13.3.3 
Circuits not conductively connected to the mains 
comply with table 10 
Such circuits are secondary 
circuit and do not include 
hazardous voltage, no basic, 
supplementary or reinforced 
insulation required. 
N/A 
13.4 
Creepage distances 
(see appended table) 
Pass 
 
Creepage distances greater than table 11 minima 
         
 Pass 
13.5 Printed 
boards 
         
 
N/A 
13.5.1 
Clearances and creepage distances between 
conductors on printed circuit boards, one of which 
may be conductively connected to the mains, as in 
fig. 10 
 
N/A 
13.5.2 
Type B coated printed circuit boards complying 
with IEC 60664-3 (basic insulation only) 
 
N/A 
13.6 
Conductive parts along uncemented joints 
clearances and creepage distances comply with 
13.3 and 13.4 
 
N/A 
 
Conductive parts along reliably cemented joints 
comply with 8.8 
 
N/A 
 
                                                                   Page 11 of 65                               Report No. SH09051258-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
13.7 
Enclosed, enveloped or hermetically sealed parts: 
not conductively connected to the mains: 
clearances and creepage distances as in table 12
         
 
N/A 
13.8 
Parts filled with insulating compound, meeting the 
requirements of 8.8 
         
 
N/A 
 
14 COMPONENTS 
 
14.1 Resistors 
 
 
a) Resistors between hazardous live parts and 
accessible metal parts 
R701, R702 
Pass 
 
b) Resistors, other than between hazardous live 
parts and accessible parts 
 N/A 
 
Resistors separately approved  .............................. : R701, R702 approved by VDE
 
Pass 
14.2 
Capacitors and RC units 
 
Pass 
 
Capacitors separately approved 
Yes  
Pass 
14.2.1 
Y capacitors tested to IEC 60384-14, 2
nd
 edition  .. : Y1: CY701, CY702, CY703, 
CY705 
Pass 
14.2.2 
X capacitors tested to IEC 60384-14, 2
nd
 edition  .. : X2: CX701, CX702, CX703 
Pass 
14.2.3 
Capacitors operating at mains frequency but not 
connected to the mains: tests for X2  ..................... :
No such component 
N/A 
14.2.5 
Capacitors with volume exceeding 1750 mm³, 
where short-circuit current exceeds 0,2 A: 
compliance with IEC60384-1, 4.38 category B or 
better ....................................................................... :
Such capacitors with metal 
cased 
N/A 
 
Capacitors with volume exceeding 1750 mm³, 
mounted closer to a potential ignition source than 
table 5 permits: compliance with IEC 60 384-1, 
4.38 category B or better ........................................ :
Such capacitors with metal 
cased 
N/A 
 
Shielded by a barrier to V-0 or metal  ..................... :  N/A 
14.3 Inductors 
and 
windings 
 
Pass 
 
Comply with IEC 61558-1, IEC 61558-2 
(as relevant) and clause 20.1.4 
 N/A 
14.3.1 
Transformers and inductors marked with 
manufacturer's name and type  .............................. :
Power transformer T701, T702 
Line filter LF704, LF705  
(See appended table14) 
Pass 
 
Transformers and inductors separately approved . : No 
N/A 
14.3.2 General 
 
Pass 
14.3.3 Constructional 
requirements 
 
Pass 
 
                                                                   Page 12 of 65                               Report No. SH09051258-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
14.3.3.1 
Clearances and creepage distances comply with 
clause 13 
(see appended table) 
Pass 
14.3.3.2 
Transformers meet the constructional 
requirements 
 Pass 
14.3.4.1 
Class II transformers have adequate separation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
T701 basic insulation 
minimum 4.0 mm between 
T701 core and primary, 
Supplementary insulation 
minimum 4.0mm between 
T701 core and secondary. 
T702 basic insulation 
minimum 4.0 mm between 
T702 core and primary, 
Supplementary insulation 
minimum 4.0mm between 
T702 core and secondary. 
Pass 
 
Coil formers and partition walls > 0,4 mm 
T701 bobbin: 0.75mm min. 
T702 bobbin: 0.75mm min. 
Pass 
14.3.4.2 
Class I transformers, with basic insulation and 
protective screening only if all 7 conditions of 
14.3.4.2 are met 
Class II construction 
N/A 
14.3.4.3 
Separating transformers with at least basic 
insulation 
 
N/A 
14.3.5.1 
Class II transformers have adequate insulation 
between hazardous live parts and accessible parts 
(double or reinforced insulation) 
T701 basic insulation 
minimum 4.0 mm between 
T701 core and primary, 
Supplementary insulation 
minimum 4.0mm between 
T701 core and secondary. 
T702 basic insulation 
minimum 4.0 mm between 
T702 core and primary, 
Supplementary insulation 
minimum 4.0mm between 
T702 core and secondary.
 
Pass 
 
Coil formers and partition walls > 0,4 mm 
T701 bobbin: 0.75mm min. 
T702 bobbin: 0.75mm min.
 
Pass 
14.3.5.2 
Class I transformers have adequate insulation 
between hazardous live parts and accessible 
conductive parts or those conductive parts or 
protective screens connected to a protective earth 
terminal 
Class II construction 
N/A 
 
                                                                   Page 13 of 65                               Report No. SH09051258-001 
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No:  IEC/EN 60065H 
 
       TRF originator Intertek ETL SEMKO SH 
 
 
 
Winding wires connected to protective earth have 
adequate current-carrying capacity 
 N/A 
14.4 
High voltage components 
No such components 
N/A 
 
High-voltage components and assemblies: 
U > 4 kV (peak) separately approved 
 
N/A 
 
Component meets category V-1 of IEC 60707 
 
N/A 
14.4.1 
High voltage transformers and multipliers tested as 
part of the submission 
 
N/A 
14.4.2 
High voltage assemblies and other parts tested as 
part of the submission 
 
N/A 
14.5 Protective 
devices 
 
Pass 
 
Protective devices used within their ratings 
 
Pass 
 
External clearances and creepage distances meet 
requirement of clause 13 for the voltage across the 
device when opened 
Fuse,  F702: 8.5mm  
F701: 5.0mm 
Pass 
14.5.1.1 
a) Thermal cut-outs separately approved 
No such components 
N/A 
 
b) Thermal cut-outs tested as part of the 
submission 
 
N/A 
14.5.1.2 
a) Thermal links separately approved 
No such components 
N/A 
 
b) Thermal links tested as part of the submission 
 
N/A 
14.5.1.3 
Thermal devices re-settable by soldering 
 
N/A 
14.5.2.1 
Fuse-links in the mains circuit according to IEC 
60127 
F702, F701 approved. 
Pass 
14.5.2.2 
Correct marking of fuse-links adjacent to holder ... : F702: T6.3A L 250V  
F701: T3.15A L 250V 
Pass 
14.5.2.3 
Not possible to connect fuses in parallel  ............... : Separate fuse holder used 
Pass 
14.5.2.4 
Not possible to touch hazardous live parts when 
replacing fuse-links without the use of a tool ......... :
 
 
Pass 
14.5.3 
PTC-S thermistors comply with IEC 60730-1 
No such parts 
N/A 
 
PTC-S devices (15 W) category V-1 or better 
 
N/A 
14.5.4 
Circuit protectors have adequate breaking capacity 
and their position is correctly marked 
 
N/A 
14.6 Switches 
No 
switch 
N/A 
Page of 68