Page 13 of 49
Report No. 910192
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
13
CLEARANCE AND CREEPAGE DISTANCES
13.1
Clearances in accordance with 13.3
P
Creepage distances in accordance with 13.4
P
13.2
Determination of operating voltage
P
13.3
Clearances
13.3.2
Circuits conductively connected to the mains
comply with table 8 and, where applicable, table 9
P
13.3.3
Circuits not conductively connected to the mains
comply with table 10
Circuits not conductively
connected to the mains cannot
cause any shock hazard
N/A
13.3.4
Measurement of transient voltages
N/A
13.4
Creepage distances
Creepage distances greater than table 11 minima
P
13.5
Printed boards
13.5.1
Clearances and creepage distances between
conductors on printed circuit boards, one of which
may be conductively connected to the mains, as in
fig. 10
N/A
13.5.2
Type B coated printed circuit boards complying with
IEC 60664-3 (basic insulation only)
N/A
13.6
Conductive parts along uncemented joints
clearances and creepage distances comply with
13.3 and 13.4
N/A
Conductive parts along reliably cemented joints
comply with 8.8
N/A
13.7
Enclosed, enveloped or hermetically sealed parts:
not conductively connected to the mains:
clearances and creepage distances as in table 12
N/A
13.8
Parts filled with insulating compound, meeting the
requirements of 8.8
N/A
Page 14 of 49
Report No. 910192
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
14
COMPONENTS
14.1
Resistors
a) Resistors between hazardous live parts and
accessible metal parts
N/A
b) Resistors, other than between hazardous live
parts and accessible parts
N/A
Resistors separately approved ...............................:
N/A
14.2
Capacitors and RC units
Capacitors separately approved
P
14.2.1
Y capacitors tested to IEC 60384-14, 2
nd
edition ...:
N/A
14.2.2
X capacitors tested to IEC 60384-14, 2
nd
edition ...: C498, C499
P
14.2.3
Capacitors operating at mains frequency but not
connected to the mains: tests for X2 ......................:
N/A
14.2.5
a) Capacitors with volume exceeding 1750 mm³,
where short-circuit current exceeds 0.2 A:
compliance with IEC 60384-1, 4.38 category B or
better .......................................................................:
N/A
b)
Capacitors with volume exceeding 1750 mm³,
mounted closer to a potential ignition source than
table 5 permits: compliance with IEC 60384-1, 4.38
category B or better ................................................:
N/A
Shielded by a barrier per Table 21..........................:
N/A
14.3
Inductors and windings
Comply with IEC 61558-1, IEC 61558-2
(as relevant) and clause 20.1.4
P
14.3.1
Transformers and inductors marked with
manufacturer's name and type ...............................:
Transtec TT0900305570-E alt.
Gloria TD-230-0250K alt.
HuiRan 150-r4055904-e
P
Transformers and inductors separately approved .: No
N/A
14.3.2
General
14.3.3, 14.3.4.1, 14.3.5.1
P
Page 15 of 49
Report No. 910192
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
14.3.3
Constructional requirements (complete appended tables or include manufacturers
constructional insulation descriptions)
14.3.3.1
Clearances and creepage distances comply with
clause 13
P
14.3.3.2
Transformers meet the constructional requirements
P
14.3.4.1
Class II transformers have adequate separation
between hazardous live parts and accessible parts
(double or reinforced insulation)
Prim.-sec: 7.1mm
P
Coil formers and partition walls = 0.4 mm
1.3 mm and thin sheet
P
14.3.4.2
Class I transformers, with basic insulation and
protective screening only if all 7 conditions of
14.3.4.2 are met
N/A
14.3.4.3
Separating transformers with at least basic
insulation
N/A
14.3.5.1
Class II transformers have adequate insulation
between hazardous live parts and accessible parts
(double or reinforced insulation)
Core not connected to
accessible parts.
N/A
Coil formers and partition walls = 0.4 mm
Thin sheet
N/A
14.3.5.2
Class I transformers have adequate insulation
between hazardous live parts and accessible
conductive parts or those conductive parts or
protective screens connected to a protective earth
terminal
N/A
Winding wires connected to protective earth have
adequate current-carrying capacity
N/A
14.4
High voltage components
High-voltage components and assemblies: U > 4 kV
(peak) separately approved
N/A
Component meets category V-1 of IEC 60707
N/A
14.4.1
High voltage transformers and multipliers tested as
part of the submission
N/A
14.4.2
High voltage assemblies and other parts tested as
part of the submission
N/A
14.5
Protective devices
Protective devices used within their ratings
P
External clearances and creepage distances meet
requirement of clause 13 for the voltage across the
device when opened
P
Page 16 of 49
Report No. 910192
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
14.5.1.1
a) Thermal cut-outs separately approved
N/A
b) Thermal cut-outs tested as part of the submission Did not open during fault
conditions
N/A
14.5.1.2
a) Thermal links separately approved
P
b) Thermal links tested as part of the submission
In transformer G4M20403-0857-L
Did not open during fault
conditions
N/A
14.5.1.3
Thermal devices re-settable by soldering
N/A
14.5.2.1
Fuse-links in the mains circuit according to
IEC 60127
Mains fuse, F501
P
14.5.2.2
Correct marking of fuse-links adjacent to holder ...: T1.6A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ................:
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .........:
Mains fuse holder separately
approved.
Tools are required.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking capacity
and their position is correctly marked
N/A
14.6
Switches
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
V-0 compliance with annex G, G.1.1
and
Peak inrush rating of switch
Measured/calculated inrush…………………………: Calculated: 23 A
P
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.3, 14.6.4
and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact voltage
< 35 V (peak)/24 V dc complying with 14.6.3 and V-
0 in annex G, G.1.1
N/A
Switch controlling = 0.2A with open contact voltage
> 35 V (peak)/24 V dc complying with 14.6.4 and V-
0 in annex G, G.1.1
N/A