Harman Kardon HKTS 2BQ (serv.man2) EMC - CB Certificate ▷ View online

Page 21 of 49
Report No. 910192
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
17
ELECTRICAL CONNECTIONS AND MECHANICAL FIXINGS
17.1
Torque test to table 20:
- screws into metal: 5 times
N/A
- screws into non-metallic material: 10 times
1.2Nm
P
17.2
Correct introduction into female threads in non-
metallic material
P
17.3
Cover fixing screws: captive
N/A
Non-captive fixing screws: no hazard when replaced
by a screw whose length is 10 times its diameter
P
17.4
No loosening of conductive parts carrying a current
> 0.2 A
N/A
17.5
Contact pressure not transmitted through plastic
other than ceramic for connections carrying a
current > 0.2 A
N/A
17.6
Stranded conductors of flexible supply cords
carrying a current > 0.2 A with screw terminals not
consolidated by solder
N/A
17.7
Cover fixing devices other than screws have
adequate strength and their positioning is
unambiguous
N/A
17.8
Fixing devices for detachable legs or stands
provided
N/A
17.9
Internal pluggable connections, affecting safety,
unlikely to become disconnected
P
18
MECHANICAL STRENGTH OF PICTURE TUBES AND PROTECTION
AGAINST THE EFFECTS OF IMPLOSION
Picture tube separately approved to IEC 61965:
N/A
Picture tube separately approved to 18.1 ...............
N/A
18.1
Picture tubes > 16 cm intrinsically protected
N/A
Non-intrinsically protected tubes > 16 cm used with
protective screen
N/A
18.2
Intrinsically protected tubes: tests on 12 samples
N/A
18.2.1
Samples subject to ageing: 6
N/A
18.2.2
Samples subject to implosion test: 6
N/A
18.2.3
Samples subject to mechanical strength test (steel
ball): 6
N/A
18.3
Non-intrinsically protected tubes tested to 18.3
N/A
Page 22 of 49
Report No. 910192
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
19
STABILITY AND MECHANICAL HAZARDS
Mass of the equipment exceeding 7 kg .................: 15kg
P
Apparatus intended to be fastened in place –
suitable instructions
N/A
19.1
Test on a plane, inclined at 10
o
to the horizontal
P
19.2
100 N force applied vertically downwards
P
19.3
Apparatus mass > 25 kg or height > 1 m or supplied
with cart or stand. Topple test.
N/A
19.4
Edges or corners not hazardous
P
19.5
Glass surfaces with an area exceeding 0.1 m² or
maximum dimension > 450 mm, pass the test of
19.5.1
N/A
19.6
Wall or ceiling mountings adequate
N/A
20
RESISTANCE TO FIRE
20.1
Electrical components and mechanical parts
a) Exemption for components contained in an
enclosure of material V-0 to IEC 60695-11-10 with
openings not exceeding 1 mm in width
N/A
b) Exemption for small components as defined in
20.1 mounted on a board of flammability category of
V-1 to IEC 60695-11-10
P
20.1.1
Electrical components meet the requirements of
Clause 14 or 20.1.4
P
20.1.2
Insulation of internal wiring working at voltages
> 4 kV or leaving an internal fire enclosure, not
contributing to the spread of fire
N/A
20.1.3
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage between
50 V and 400 V (peak) a.c. or d.c. meets V-1 or
better to IEC 60707, unless used in a fire enclosure
P
Material of printed circuit boards on which the
available power exceeds 15 W at a voltage >400 V
(peak) a.c. or d.c. meets V-0 to IEC 60707
N/A
20.1.4
Components and parts not covered by 20.1.1,
20.1.2 and 20.1.3 (other than fire enclosures)
mounted nearer to a potential ignition source than
the distances in Table 21 comply with the relevant
flammability category in Table 21
(see critical components)
P
Components and parts as above but shielded from
a potential ignition source, with the barrier area in
accordance with Table 21 and fig. 13
N/A
Page 23 of 49
Report No. 910192
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
Apparatus with voltages > 4 kV under normal
conditions, and distances to enclosure exceed
those specified by Table 21, HB40 min enclosure
N/A
20.2
Fire enclosure
20.2.1
Potential ignition sources with open circuit voltage
> 4 kV (peak) a.c. or d.c. contained in a fire
enclosure to V-1
N/A
20.2.2
Internal fire enclosures with openings not exceeding
1 mm in width and with openings for wires
completely filled
N/A
20.2.3
Requirements of 20.2.1 and 20.2.2 met by an
internal fire enclosure
N/A
Page 24 of 49
Report No. 910192
IEC 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IEC60065F
TRF Originator: ASTA BEAB
A
ANNEX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
N/A
A.10.2.1
Enclosure provides protection against splashing
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
ANNEX B, APPARATUS TO BE CONNECTED TO THE TELECOMMUNICATION
NETWORKS
Complies with IEC 62151 clause 1
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N/A
Complies with IEC 62151 clause 5 but with 5.3.1
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
L
ANNEX L, ELECTRONIC FLASH APPARATUS FOR PHOTOGRAPHIC
PURPOSES
L.5.4
Battery chargers and supply apparatus marked with
model number.
N/A
L7.1.5
Lithium batteries: temperature rise (Normal)
N/A
L.9.1.1
Flash synchroniser teminals not hazardous live.
N/A
L.11.2.6
Lithium batteries: temperature rise (Fault).
N/A
L.14.6.6
Peak surge current and rated mains current not to
exceed mains switch current rating
N/A
Page of 61