DOWNLOAD Harman Kardon HKTS 11 (serv.man12) Service Manual ↓ Size: 1.59 MB | Pages: 38 in PDF or view online for FREE

Model
HKTS 11 (serv.man12)
Pages
38
Size
1.59 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hkts-11-sm12.pdf
Date

Harman Kardon HKTS 11 (serv.man12) EMC - CB Certificate ▷ View online

 
 File 
No. 
F24258-02-00HM
, page 20 of 27 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.1 
5.6 
 Immunity requirements - S3 
For test instruments and accessories used see section 6 Part S 3
5.6.1 
Description of the test location 
 
Test location: 
Test location no. 2 
 
5.6.2 
Photo documentation of the test set-up 
 
 
 
5.6.3 Test 
result 
 
 
 
The requirements are FULFILLED. 
 
Remarks: 
For detailed results, please see the attachment A.  
 
 
Operation mode: 60 Hz audio signal. 
 
 
 
 
 
 
 
 File 
No. 
F24258-02-00HM
, page 21 of 27 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.1 
5.7 
 Electrostatic discharge 
For test instruments and accessories used see section 6 Part I 2
5.7.1 
Description of the test location 
 
Test location: 
Shielded room no. 3 
 
5.7.2 
Photo documentation of the test set-up 
 
 
 
 
Legend 
C: Contact discharge 
A: Air discharge 
C
 
 File 
No. 
F24258-02-00HM
, page 22 of 27 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.1 
5.7.3 Test 
specification: 
 
Contact discharge voltage: 
2 kV 
4 kV 
 
Air discharge voltage: 
2 kV 
4 kV 
8 kV 
 
Discharge impedance: 
330 
Ω / 150 pF 
 
Discharge factor: 
≥ 1 sec. 
 
Number of discharges: 
≥ 10 
 
Type of discharge: 
Direct discharge: 
- Contact discharge 
 
- Air discharge 
 
Indirect discharge: 
- Contact discharge 
 
Polarity: 
- positive 
- negative 
 
Discharge location: 
- see photo documentation of the test set-up 
- all external locations accessible by hand 
- vertical coupling plate (VCP) 
- horizontal plate (HCP) 
 
5.7.4 Test 
result 
 
The requirements are FULFILLED. 
Performance Criterion:
 B 
 
Remarks: 
During electrostatic discharge the sine wave was disturbed. After test sound and level was ok. 
 
 
Operation mode: 60 Hz 1/8 power. 
 
 
 
 
 
 
 
 File 
No. 
F24258-02-00HM
, page 23 of 27 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.1 
5.8 Radiated, 
radio-frequency, electromagnetic field 
For test instruments and accessories used see section 6 Part I 3
5.8.1 
Description of the test location 
 
Test location: 
Absorber chamber no. 2 
 
5.8.2 
Photo documentation of the test set-up 
 
 
 
5.8.3 Test 
specification: 
 
Frequency range: 
900 MHz Pulse modulation 
 
Field strength: 3 
V/m 
 
EuT - antenna separation: 3 
 
Modulation: 
PM / square wave: 217 Hz / duty cycle: 12.5 % 
 
Antenna polarisation: - 
vertical 
 
 
5.8.4 Test 
result 
 
The requirements are FULFILLED. 
Performance Criterion:
 A 
 
Remarks: 
Operation mode: 60 Hz audio signal. 
Page of 38