Harman Kardon HKTS 11 (serv.man12) EMC - CB Certificate ▷ View online
File
No.
F24258-02-00HM
, page 20 of 27
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
5.6
Immunity requirements - S3
For test instruments and accessories used see section 6 Part S 3.
5.6.1
Description of the test location
Test location:
Test location no. 2
5.6.2
Photo documentation of the test set-up
5.6.3 Test
result
The requirements are FULFILLED.
Remarks:
For detailed results, please see the attachment A.
Operation mode: 60 Hz audio signal.
File
No.
F24258-02-00HM
, page 21 of 27
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
5.7
Electrostatic discharge
For test instruments and accessories used see section 6 Part I 2.
5.7.1
Description of the test location
Test location:
Shielded room no. 3
5.7.2
Photo documentation of the test set-up
Legend
C: Contact discharge
A: Air discharge
C
A
File
No.
F24258-02-00HM
, page 22 of 27
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
5.7.3 Test
specification:
Contact discharge voltage:
2 kV
/
4 kV
Air discharge voltage:
2 kV
/
4 kV
/
8 kV
Discharge impedance:
330
Ω / 150 pF
Discharge factor:
≥ 1 sec.
Number of discharges:
≥ 10
Type of discharge:
Direct discharge:
- Contact discharge
- Air discharge
Indirect discharge:
- Contact discharge
Polarity:
- positive
- negative
Discharge location:
- see photo documentation of the test set-up
- all external locations accessible by hand
- vertical coupling plate (VCP)
- horizontal plate (HCP)
- all external locations accessible by hand
- vertical coupling plate (VCP)
- horizontal plate (HCP)
5.7.4 Test
result
The requirements are FULFILLED.
Performance Criterion:
B
Remarks:
During electrostatic discharge the sine wave was disturbed. After test sound and level was ok.
Operation mode: 60 Hz 1/8 power.
File
No.
F24258-02-00HM
, page 23 of 27
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
5.8 Radiated,
radio-frequency, electromagnetic field
For test instruments and accessories used see section 6 Part I 3.
5.8.1
Description of the test location
Test location:
Absorber chamber no. 2
5.8.2
Photo documentation of the test set-up
5.8.3 Test
specification:
Frequency range:
900 MHz Pulse modulation
Field strength: 3
V/m
EuT - antenna separation: 3
m
Modulation:
PM / square wave: 217 Hz / duty cycle: 12.5 %
Antenna polarisation: -
vertical
5.8.4 Test
result
The requirements are FULFILLED.
Performance Criterion:
A
Remarks:
Operation mode: 60 Hz audio signal.
Click on the first or last page to see other HKTS 11 (serv.man12) service manuals if exist.