Harman Kardon HKTS 11 (serv.man12) EMC - CB Certificate ▷ View online
File
No.
F24258-02-00HM
, page 12 of 27
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
5.2 Disturbance
power
For test instruments and accessories used see section 6 Part A 7.
5.2.1
Description of the test location
Test location:
Shielded room no. 7
5.2.2
Photo documentation of the test set-up
5.2.3 Test
result
Frequency range:
30 MHz - 300 MHz
Min. limit margin
>5 dB at 30 - 300 MHz
The requirements are FULFILLED.
Remarks:
For detailed results, please see the following page(s).
File
No.
F24258-02-00HM
, page 13 of 27
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
5.2.4 Test
protocol
Test point:
Power cord, Line, SUB IN
Operation mode:
60 Hz 1/8 power
Remarks: n/a
Result: passed
30-300
<25
Power
AV
[dBpW]
Dlimit AV
[dB]
Power
QP
[dBpW]
Dlimit QP
[dB]
Frequency
[MHz]
Reading
QP
[dBpW]
Correct.
[dB]
Limit AV
[dBpW]
Reading
AV
[dBpW]
Limit QP
[dBpW]
0
10
20
30
40
50
60
70
80
0
50
100
150
200
250
300
f [MHz]
dBpW
Limit QP (Frequency range: 30 - 300 MHz)
Limit AV (Frequency range: 30 - 300 MHz)
Power QP dBpW
Power AV dBpW
Limit AV (Frequency range: 30 - 300 MHz)
Power QP dBpW
Power AV dBpW
QP
AV
<25dB(pW)
File
No.
F24258-02-00HM
, page 14 of 27
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
Test point:
High Level
Operation mode:
60 Hz 1/8 power
Remarks: n/a
Result: passed
49,600
30,0
1,3
31,3
45,7
-14,4
51,300
29,0
1,2
30,2
45,8
-15,6
59,800
27,0
0,8
27,8
46,1
-18,3
Power
AV
[dBpW]
Dlimit AV
[dB]
Power
QP
[dBpW]
Dlimit QP
[dB]
Frequency
[MHz]
Reading
QP
[dBpW]
Correct.
[dB]
Limit AV
[dBpW]
Reading
AV
[dBpW]
Limit QP
[dBpW]
0
10
20
30
40
50
60
70
80
0
50
100
150
200
250
300
f [MHz]
dBpW
Limit QP (Frequency range: 30 - 300 MHz)
Limit AV (Frequency range: 30 - 300 MHz)
Power QP dBpW
Power AV dBpW
Limit AV (Frequency range: 30 - 300 MHz)
Power QP dBpW
Power AV dBpW
QP
AV
<25dB(pW)
File
No.
F24258-02-00HM
, page 15 of 27
MIKES BABT Product Service GmbH
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60
Rev. No. 9.1
5.3 Harmonic
current
For test instruments and accessories used see section 6 Part H & Fl.
5.3.1
Description of the test location
Test location:
Test location no. 1
5.3.2
Photo documentation of the test set-up
5.3.3 Test
result
The requirements are FULFILLED.
Remarks:
For detailed results, please see the following page(s).