DOWNLOAD Harman Kardon HKTS 11 (serv.man12) Service Manual ↓ Size: 1.59 MB | Pages: 38 in PDF or view online for FREE

Model
HKTS 11 (serv.man12)
Pages
38
Size
1.59 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hkts-11-sm12.pdf
Date

Harman Kardon HKTS 11 (serv.man12) EMC - CB Certificate ▷ View online

 
 File 
No. 
F24258-02-00HM
, page 12 of 27 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.1 
5.2 Disturbance 
power 
For test instruments and accessories used see section 6 Part A 7
5.2.1 
Description of the test location 
 
Test location: 
Shielded room no. 7 
 
5.2.2 
Photo documentation of the test set-up 
 
 
 
5.2.3 Test 
result 
 
Frequency range: 
30 MHz - 300 MHz 
 
Min. limit margin 
>5 dB at 30 - 300 MHz 
 
The requirements are FULFILLED. 
 
Remarks: 
For detailed results, please see the following page(s).  
 
 
 
 
 
 
 
 
 
 
 File 
No. 
F24258-02-00HM
, page 13 of 27 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.1 
5.2.4 Test 
protocol 
 
Test point:  
Power cord, Line, SUB IN 
Operation mode: 
60 Hz 1/8 power 
Remarks: n/a 
Result: passed 
 
30-300
<25
Power
AV
[dBpW]
Dlimit AV
[dB]
Power
QP
[dBpW]
Dlimit QP
[dB]
Frequency
[MHz]
Reading 
QP
[dBpW]
Correct.
[dB]
Limit AV
[dBpW]
Reading 
AV
[dBpW]
Limit QP
[dBpW]
 
 
0
10
20
30
40
50
60
70
80
0
50
100
150
200
250
300
f [MHz]
dBpW
Limit QP (Frequency range: 30 - 300 MHz)
Limit AV (Frequency range: 30 - 300 MHz)
Power QP  dBpW
Power AV  dBpW
QP
AV
<25dB(pW)
 
 
 File 
No. 
F24258-02-00HM
, page 14 of 27 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.1 
 
Test point:  
High Level 
Operation mode: 
60 Hz 1/8 power 
Remarks: n/a 
Result: passed 
 
49,600
30,0
1,3
31,3
45,7
-14,4
51,300
29,0
1,2
30,2
45,8
-15,6
59,800
27,0
0,8
27,8
46,1
-18,3
Power
AV
[dBpW]
Dlimit AV
[dB]
Power
QP
[dBpW]
Dlimit QP
[dB]
Frequency
[MHz]
Reading 
QP
[dBpW]
Correct.
[dB]
Limit AV
[dBpW]
Reading 
AV
[dBpW]
Limit QP
[dBpW]
 
 
0
10
20
30
40
50
60
70
80
0
50
100
150
200
250
300
f [MHz]
dBpW
Limit QP (Frequency range: 30 - 300 MHz)
Limit AV (Frequency range: 30 - 300 MHz)
Power QP  dBpW
Power AV  dBpW
QP
AV
<25dB(pW)
 
 
 File 
No. 
F24258-02-00HM
, page 15 of 27 
 
MIKES BABT Product Service GmbH 
x Ohmstrasse 2-4 x D-94342 Strasskirchen x Tel.:+49 9424-9407-0 x Fax:+49 9424-9407-60 
Rev. No. 9.1 
5.3 Harmonic 
current 
For test instruments and accessories used see section 6 Part H & Fl
5.3.1 
Description of the test location 
 
Test location: 
Test location no. 1 
 
5.3.2 
Photo documentation of the test set-up 
 
 
 
5.3.3 Test 
result 
 
The requirements are FULFILLED. 
 
Remarks: 
For detailed results, please see the following page(s). 
 
 
 
 
 
 
 
 
 
Page of 38
Display