DOWNLOAD Harman Kardon HK 3490 (serv.man2) Service Manual ↓ Size: 1.91 MB | Pages: 63 in PDF or view online for FREE

Model
HK 3490 (serv.man2)
Pages
63
Size
1.91 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
hk-3490-sm2.pdf
Date

Harman Kardon HK 3490 (serv.man2) EMC - CB Certificate ▷ View online

 
 
- Page 31 of 45 - 
 
 
 
 
 Report 
No. 
98503 
 
 
 
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH 
PROTECTION AGAINST SPLASHING WATER 
 
A.5.1 
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not 
apply 
Not intended for outdoor  
use
 
N/A 
A.10.2.1 
Enclosure provides protection against splashing 
water 
 
N/A 
A.10.2.2 
Humidity treatment carried out for 7 days 
See clause above
 
N/A 
 
 
 
 
APPENDIX B, APPARATUS TO BE CONNECTED TO THE 
TELECOMMUNICATION NETWORKS 
 
 
Complies with IEC 62151 clause 1 
No TNV circuits
 
N/A 
 
Complies with IEC 62151 clause 2 
 
N/A 
 
Complies with IEC 62151 clause 3 but with 3.5.4 
modified to 2.4.10 of this standard 
         
 
N/A 
 
Complies with IEC 62151 clause 4 but with 4.1.2, 
4.1.3 and 4.2.1.2 modified in accordance with 
annex B of this standard 
         
 
N/A 
 
Complies with IEC 62151 cause 5 but with 5.3.1 
modified in accordance with annex B of this 
standard 
         
 
N/A 
 
Complies with IEC 62151 clause 6  
         
 
N/A 
 
Complies with IEC 62151 clause 7  
         
 
N/A 
 
Complies with IEC 62151 annex A, B and C 
         
 
N/A 
 
 
 
- Page 32 of 45 - 
 
 
 
 
 Report 
No. 
98503 
 
 
 
 
IEC 62151 clause 4.1.1: 
Add after the first paragraph: 
 
NOTE- In Finland, Norway and Sweden, class I 
equipment which is intended for connection to the 
building installation via a non-industrial plug or a 
non-industrial appliance coupler, or both and in 
addition is intended for connection to other 
equipment or a network shall, if safety relies on 
connection to protective earth or if surge 
suppressors are connected between the network 
terminals and ACCESSIBLE parts, have a marking 
stating that the equipment must be connected to 
an earthed mains socket-outlet. 
 
The marking text in the applicable countries shall 
be as follow: 
 
In Finland,  
"Laite on liitettävä suojamaadoituskoskettimilla 
va rustettuunpistorasiaan” 
 
In Norway, 
"Apparatet må tilkoples jordet stikkontakt" 
 
In Sweden, 
"Apparaten skall anslutas till jordat uttag” 
Class II apparatus 
N/A 
 
 
 
 
APPENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH 
APPARATUS FOR PHOTOGRAPHIC PURPOSES. 
N/A 
L5.4 
Marking and Instructions 
 N/A 
L9.1.1 
Terminals to connection to synchroniser not 
HAZARDOUS LIVE 
 
N/A 
L7.1.5 & 
L11.2.6 
Lithium batteries meet permissible temp rise in 
Table  3 , unless comply with 6.3.2 of IEC 60086-4 
 
N/A 
L14.6.6 
Mains switch characteristics   appropriate to its 
function under normal conditions 
 
N/A 
 
 
No electronic flash  
apparatus 
N/A 
 
 
- Page 33 of 45 - 
 
 
 
 
 Report 
No. 
98503 
 
 
7.1 
TABLE: temperature rise measurements 
 
Power consumption in the OFF/Stand-by 
In OFF/Stand-by position,  
the power consumption is less  
than 1,64W.
 
— 
 
Position of the functional switch (W)  ................ :
— 
Operating conditions 
Standby mode at 50Hz;
 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
230 0,013 1,64  — 
220 0,013 1,52  — 
Standby mode at 60Hz; 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
230 0,013 1,52  — 
220 0,013 1,42  — 
 
Measured at maximum non-clipped output at 50Hz;
 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
253 4,05 842 
111,8 W 
(SPK 1) 
2 x 111,0 W 
(SPK 2) 
Measured at maximum non-clipped output at 60Hz; 
253 3,97 828 
111,8 W 
(SPK 1) 
2 x 111,0 W 
(SPK 2) 
Tested condition: 1kHz input signal, connected 8 ohm loads for Speaker 1 and Speaker 2 channels 
 
 
- Page 34 of 45 - 
 
 
 
 
 Report 
No. 
98503 
 
 
Measured at 1/8 of maximum non-clipped output at 50Hz; 
Un (V) 
In (A) 
Pn (W) 
Pout (W) 
253 
1,80 341 
2 x 14,0 W 
(SPK 1) 
2 x 13,9 W 
(SPK 2) 
230 
1,76 303 
2 x 14,0 W 
(SPK 1) 
2 x 13,9 W 
(SPK 2) 
220 
1,74 289 
2 x 14,0 W 
(SPK 1) 
2 x 13,9 W 
(SPK 2) 
198 
1,69 255 
2 x 14,0 W 
(SPK 1) 
2 x 13,9 W 
(SPK 2) 
Measured at 1/8 of maximum non-clipped output at 60Hz; 
253 
1,78 338 
2 x 14,0 W 
(SPK 1) 
2 x 13,9 W 
(SPK 2) 
242 
1,76 320 
2 x 14,0 W 
(SPK 1) 
2 x 13,9 W 
(SPK 2) 
230 
1,73 300 
2 x 14,0 W 
(SPK 1) 
2 x 13,9 W 
(SPK 2) 
220 
1,71 285 
2 x 14,0 W 
(SPK 1) 
2 x 13,9 W 
(SPK 2) 
198 
1,67 253 
2 x 14,0 W 
(SPK 1) 
2 x 13,9 W 
(SPK 2) 
Tested condition: 1kHz input signal, connected 8 ohm loads for Speaker 1 and Speaker 2 channels 
 
         
 
Loudspeaker impedance (Ω)  ......
8 Ohm 
— 
         
 
Several loudspeaker systems 
SPEAKER 1 : Right and Left 
SPEAKER 2 : Right and Left 
         
 
Marking of loudspeaker 
terminals 
SPEAKER 1 ( 8 
Ω ), 
SPEAKER 2 ( 8 
Ω ) 
 
Page of 63