Harman Kardon HK 3490 (serv.man2) EMC - CB Certificate ▷ View online
- Page 31 of 45 -
Report
No.
98503
A
APPENDIX A, ADDITIONAL REQUIREMENTS FOR APPARATUS WITH
PROTECTION AGAINST SPLASHING WATER
PROTECTION AGAINST SPLASHING WATER
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
Not intended for outdoor
use
use
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
See clause above
N/A
B
APPENDIX B, APPARATUS TO BE CONNECTED TO THE
TELECOMMUNICATION NETWORKS
TELECOMMUNICATION NETWORKS
Complies with IEC 62151 clause 1
No TNV circuits
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
4.1.3 and 4.2.1.2 modified in accordance with
annex B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
- Page 32 of 45 -
Report
No.
98503
IEC 62151 clause 4.1.1:
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to the
building installation via a non-industrial plug or a
non-industrial appliance coupler, or both and in
addition is intended for connection to other
equipment or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
terminals and ACCESSIBLE parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follow:
In Finland,
"Laite on liitettävä suojamaadoituskoskettimilla
va rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Add after the first paragraph:
NOTE- In Finland, Norway and Sweden, class I
equipment which is intended for connection to the
building installation via a non-industrial plug or a
non-industrial appliance coupler, or both and in
addition is intended for connection to other
equipment or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
terminals and ACCESSIBLE parts, have a marking
stating that the equipment must be connected to
an earthed mains socket-outlet.
The marking text in the applicable countries shall
be as follow:
In Finland,
"Laite on liitettävä suojamaadoituskoskettimilla
va rustettuunpistorasiaan”
In Norway,
"Apparatet må tilkoples jordet stikkontakt"
In Sweden,
"Apparaten skall anslutas till jordat uttag”
Class II apparatus
N/A
L
APPENDIX L, ADDITIONAL REQUIREMENTS FOR ELECTRONIC FLASH
APPARATUS FOR PHOTOGRAPHIC PURPOSES.
APPARATUS FOR PHOTOGRAPHIC PURPOSES.
N/A
L5.4
Marking and Instructions
N/A
L9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L7.1.5 &
L11.2.6
Lithium batteries meet permissible temp rise in
Table 3 , unless comply with 6.3.2 of IEC 60086-4
Table 3 , unless comply with 6.3.2 of IEC 60086-4
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
No electronic flash
apparatus
apparatus
N/A
- Page 33 of 45 -
Report
No.
98503
7.1
TABLE: temperature rise measurements
P
Power consumption in the OFF/Stand-by
In OFF/Stand-by position,
the power consumption is less
than 1,64W.
the power consumption is less
than 1,64W.
—
Position of the functional switch (W) ................ :
-
—
Operating conditions
Standby mode at 50Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
230 0,013 1,64 —
220 0,013 1,52 —
Standby mode at 60Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
230 0,013 1,52 —
220 0,013 1,42 —
Measured at maximum non-clipped output at 50Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
253 4,05 842
2
x
111,8 W
(SPK 1)
2 x 111,0 W
(SPK 2)
Measured at maximum non-clipped output at 60Hz;
253 3,97 828
2
x
111,8 W
(SPK 1)
2 x 111,0 W
(SPK 2)
Tested condition: 1kHz input signal, connected 8 ohm loads for Speaker 1 and Speaker 2 channels
- Page 34 of 45 -
Report
No.
98503
Measured at 1/8 of maximum non-clipped output at 50Hz;
Un (V)
In (A)
Pn (W)
Pout (W)
253
1,80 341
2 x 14,0 W
(SPK 1)
2 x 13,9 W
(SPK 2)
230
1,76 303
2 x 14,0 W
(SPK 1)
2 x 13,9 W
(SPK 2)
220
1,74 289
2 x 14,0 W
(SPK 1)
2 x 13,9 W
(SPK 2)
198
1,69 255
2 x 14,0 W
(SPK 1)
2 x 13,9 W
(SPK 2)
Measured at 1/8 of maximum non-clipped output at 60Hz;
253
1,78 338
2 x 14,0 W
(SPK 1)
2 x 13,9 W
(SPK 2)
242
1,76 320
2 x 14,0 W
(SPK 1)
2 x 13,9 W
(SPK 2)
230
1,73 300
2 x 14,0 W
(SPK 1)
2 x 13,9 W
(SPK 2)
220
1,71 285
2 x 14,0 W
(SPK 1)
2 x 13,9 W
(SPK 2)
198
1,67 253
2 x 14,0 W
(SPK 1)
2 x 13,9 W
(SPK 2)
Tested condition: 1kHz input signal, connected 8 ohm loads for Speaker 1 and Speaker 2 channels
Loudspeaker impedance (Ω) ......
8 Ohm
—
Several loudspeaker systems
SPEAKER 1 : Right and Left
SPEAKER 2 : Right and Left
SPEAKER 2 : Right and Left
P
Marking of loudspeaker
terminals
terminals
SPEAKER 1 ( 8
Ω ),
SPEAKER 2 ( 8
Ω )
P