Harman Kardon HK 3490 (serv.man2) EMC - CB Certificate ▷ View online
- Page 19 of 45 -
Report
No.
98503
14.5.1.2
a) Thermal links separately approved
The thermal links in
main and sub transformer
separately approved.
See appended table, list of
critical components
main and sub transformer
separately approved.
See appended table, list of
critical components
P
b) Thermal links tested as part of the submission
N/A
14.5.1.3
Thermal devices re-settable by soldering
No thermal devices
re-settable
re-settable
N/A
14.5.2.1
Fuse-links in the mains circuit according to IEC
60127
60127
Fuses are approved
components according to
components according to
IEC 60127.
See list of critical components
See list of critical components
P
14.5.2.2
Correct marking of fuse-links adjacent to holder
................................................................................. :
................................................................................. :
Correct marking applied
close to the fuses;
F101: T6.3A L 250V,
F102: T2.5A L 250V,
F603, F604: T8A L 250V
close to the fuses;
F101: T6.3A L 250V,
F102: T2.5A L 250V,
F603, F604: T8A L 250V
P
14.5.2.3
Not possible to connect fuses in parallel ......... :
No fuses holder so
designed that fuse-links
can be connected in parallel
designed that fuse-links
can be connected in parallel
P
14.5.2.4
Not possible to touch hazardous live parts when
replacing fuse-links without the use of a tool .. :
replacing fuse-links without the use of a tool .. :
No replacement of fuses
possible by hand.
possible by hand.
P
14.5.3
PTC-S thermistors comply with IEC 60730-1
No PTC’s thermistors.
N/A
PTC-S devices (15 W) category V-1 or better
N/A
14.5.4
Circuit protectors have adequate breaking
capacity and their position is correctly marked
capacity and their position is correctly marked
N/A
14.6 Switches
P
14.6.1 a)
Separate testing to IEC 61058 including:
10 000 operations
Normal pollution suitability
Resistance to heat and fire level 3
and
Make and break speed independent of speed of
actuation
actuation
V-0 compliance with annex G, G.1.1
Yes, mains switch and relay
provided. Certified acc. to
IEC61058-1.
- Mains relay, certified by
SEMKO.
- Mains switch, certified by
FIMKO.
See appended table, list of
critical components.
provided. Certified acc. to
IEC61058-1.
- Mains relay, certified by
SEMKO.
- Mains switch, certified by
FIMKO.
See appended table, list of
critical components.
P
- Page 20 of 45 -
Report
No.
98503
14.6.1 b)
Tested in the apparatus:
N/A
Switch controlling > 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.3, 14.6.4 and V-0 in annex G, G.1.1
N/A
Switch controlling > 0.2A with open contact
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
voltage < 35 V (peak)/24 V dc complying with
14.6.3 and V-0 in annex G, G.1.1
N/A
Switch controlling < 0.2A with open contact
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
voltage > 35 V (peak)/24 V dc complying with
14.6.4 and V-0 in annex G, G.1.1
N/A
14.6.2
Switch tested to 14.6.1 b) constructed to IEC
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
61058-1 subclause 13.1 and has making/breaking
action independent of speed of actuation
Separately approved relay.
N/A
14.6.3
Switch tested to 14.6.1 b) compliant with IEC
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
61058-1 subclause 16.2.2 d) and m) not attaining
excessive temperatures in use
Separately approved relay.
N/A
14.6.4
Switch tested to 14.6.1 b) has adequate dielectric
strength
strength
Separately approved relay.
N/A
14.6.5
Mains switch controlling mains socket outlets
additional tests to IEC 60058-1
additional tests to IEC 60058-1
Measured inrush current
through mains switch is
through mains switch is
< 1 A.
The measured inrush current
is less than rated current of
the mains switch (6A) - O.K.
Measured inrush current
through mains relay =
31A + 50 A *
*) Added current for socket
outlet (0.5A x 2 provided)
is less than rated current of
the mains switch (6A) - O.K.
Measured inrush current
through mains relay =
31A + 50 A *
*) Added current for socket
outlet (0.5A x 2 provided)
.
The measured surge current
value is less than rated inrush
current rating of the mains
relay (120A). - O.K.
(The mains socket outlet is
controlled by the mains relay).
P
Socket outlet current marking correct
Adequate current marking
provided.
See
provided.
See
copy of marking plate
P
- Page 21 of 45 -
Report
No.
98503
14.7 Safety
interlocks
No safety interlock
N/A
Safety interlocks to 2.8 of IEC 60950
N/A
14.8
Voltage setting devices
and the like
No voltage setting devices
N/A
Voltage setting device not likely to be changed
accidentally
accidentally
N/A
14.9 Motors
No motors
N/A
14.9.1
Endurance test on motors
N/A
Motor start test
N/A
Dielectric strength test
N/A
14.9.2
Not adversely affected by oil or grease etc.
N/A
14.9.3
Protection against moving parts
N/A
14.9.4
Motors with phase-shifting capacitors, three-
phase motors and series motors meet clause. B.8,
B.9 and B.10 of IEC 60950, Annex B
phase motors and series motors meet clause. B.8,
B.9 and B.10 of IEC 60950, Annex B
No such construction.
N/A
14.10 Batteries
No batteries
N/A
14.10.1
Batteries mounted with no risk of accumulation of
flammable gases
flammable gases
P
14.10.2
No possibility of recharging non-rechargeable
batteries
batteries
N/A
14.10.3
Recharging currents and times within
manufacturers limits
manufacturers limits
N/A
Lithium batteries discharge and reverse currents
within the manufacturers limits
within the manufacturers limits
N/A
14.10.4
Battery mould stress relief
N/A
14.10.5
Battery drop test
N/A
14.11 Optocouplers
No optocouplers
N/A
Optocouplers comply with Cl. 8
N/A
Internal and external dimensions to 13.1. or
alternatively 13.6 (jointed insulation)
alternatively 13.6 (jointed insulation)
N/A
- Page 22 of 45 -
Report
No.
98503
14.12
Surge suppression varistors
No surge suppression
varistors
varistors
N/A
Comply with IEC 61051-2
N/A
Not connected between mains and accessible
parts except for earthed parts of permanently
connected apparatus
parts except for earthed parts of permanently
connected apparatus
N/A
Complies with the current pulse, fire hazard and
thermal stress requirements of 14.12
thermal stress requirements of 14.12
N/A
15 TERMINALS
15.1.1
Mains plug, appliance inlet, interconnection
couplers and mains socket-outlet meet the
appropriate standard
couplers and mains socket-outlet meet the
appropriate standard
Approved mains plug and
socket-outlet provided, see
list of critical components.
socket-outlet provided, see
list of critical components.
P
Overloading of plugs or appliance inlets
prevented if the apparatus has mains socket
outlets
prevented if the apparatus has mains socket
outlets
Prevented by the fuse;
F102 (T2.5A L 250V).
P
Overloading of internal wiring prevented if the
apparatus has mains socket outlets
apparatus has mains socket outlets
No internal wirings for
socket-outlets.
socket-outlets.
N/A
15.1.2
Connectors for antenna, earth, audio, video or data:
P
No risk of insertion in mains socket-outlets
Only phono/RCA, Optical,
Mini jack and Antenna
terminals used. Banana
plug type speaker terminal “
also used, but they are
accepted due to below note.
Note:
Banana plug type speaker
terminals are blocked in
their axial holes to prevent
use of plugs that can make
permanent contact with a
mains socket outlet.
Mini jack and Antenna
terminals used. Banana
plug type speaker terminal “
also used, but they are
accepted due to below note.
Note:
Banana plug type speaker
terminals are blocked in
their axial holes to prevent
use of plugs that can make
permanent contact with a
mains socket outlet.
P
No risk of insertion into audio or video: outlets
marked with the symbol of 5.2
marked with the symbol of 5.2
No sockets indicated with
the symbol
the symbol
N/A
15.1.3
Output terminals of a.c. adaptors or similar
devices not compatible with household mains
socket-outlets
devices not compatible with household mains
socket-outlets
The equipment under test
is not an adaptor.
is not an adaptor.
N/A