4.3
 
Mains Terminal Continuous Disturbance Voltage 
Result: 
     Passed 
 
Date of testing 
:   25.01.2010 
Test procedure 
:   EN 55013:2001+A1+A2 and CISPR 16-1 series   
 standards 
Frequency range 
:   0.15 – 30MHz 
Bandwidth of EMI receiver  
9kHz 
Detector 
Peak, quasi-peak, average 
Final measurement time 
1s 
Kind of test site 
:   Shielded room 
Input voltage 
:   AC 230V, 50Hz 
Ambient Condition 
:  Temperature: 16
o
C; Relative Humidity: 60% 
 
The measurement setup was made according to EN 55013:2001+A1+A2 in a shielded room. 
The  measurement  equipment  like  test  receivers,  quasi-peak  detector  and  artificial  mains 
network (AMN) are in compliance with CISPR 16-1 series standards.  
The  tested  object  was  set-up  on  a  wooden  table.  The  EUT  was  set  0.8m  away  from  the 
AMN.  The  cord  longer  than  necessary  to  be  connected  to  the  AMN  was  folded  forth  and 
back parallel so as to form a bundle with a length between 0.3m and 0.4m.  
The disturbance voltage was determined according to clause 5.3 of EN 55013:2001+A1+A2 
while measuring the line and neutral conductor by turns.  
 
The  following  figures  and  tables  were  those  measured  by  an  automatic  measuring  system. 
Both  quasi-peak  and  average  measurements  were  performed.  In  the  following  spectral 
diagram, “x” means quasi-peak test results and “+” means average test results. 
 
 
 
Produkte 
Products
 
 
 
 
 
Prüfbericht - Nr.:
 
Test Report No.:
 
15036107 001
 
Seite 10 von 33 
Page 10 of 33 
 
 
Figure 1: Spectrum diagram and measurement results, mains terminal disturbance voltage, 
150kHz - 30MHz, line L  
 
Figure 2: Spectrum diagram and measurement results, mains terminal disturbance voltage, 
150kHz - 30MHz, line N  
 
 
 
 
Produkte 
Products
 
 
 
 
 
Prüfbericht - Nr.:
 
Test Report No.:
 
15036107 001
 
Seite 11 von 33 
Page 11 of 33 
 
 
Quasi-peak measurement results:
 
Frequency 
(MHz) 
  Quasi-peak results 
   (dBµV) 
Limit 
(dBµV) 
Margin 
(dB) 
0.159 
46.6 
65.5 
18.9 
3.732 
29.5 
56.0 
26.5 
4.574 
36.1 
56.0 
19.9 
 
Average measurement results: 
 
 
Frequency 
(MHz) 
Average results 
(dBµV) 
Limit 
(dBµV) 
Margin 
(dB) 
0.272 
32.3 
51.1 
18.8 
0.496 
29.3 
46.1 
16.8 
1.063 
25.8 
46.0 
20.2 
3.214 
27.9 
46.0 
18.1 
4.664 
28.6 
46.0 
17.4 
6.156 
30.6 
50.0 
19.4 
 
 
 
Produkte 
Products
 
 
 
 
 
Prüfbericht - Nr.:
 
Test Report No.:
 
15036107 001
 
Seite 12 von 33 
Page 12 of 33 
 
 
4.4
 
Disturbance Power 
Result: 
     Passed 
 
Date of testing 
 25.01.2010 
Test procedure 
 EN 55013:2001+A1+A2 and CISPR 16-1 series  
 standards 
Frequency range 
 30-300MHz 
Bandwidth of EMI receiver  
120kHz 
Detector 
Peak, quasi-peak, average 
Kind of test site 
 Shielded room 
Input voltage  
 AC 230V, 50Hz 
Operating mode 
 Continuously operating mode 
Ambient Condition 
Temperature: 16
o
C; Relative Humidity: 60% 
 
The measurement setup was made according to EN 55013:2001+A1+A2 in a shielded room. 
The  measurement  equipment  like  test  receivers,  quasi-peak  detector  and  power  absorbing 
clamp are in compliance with CISPR 16-1 series standards. The tested object was operated 
under its rated voltage and its rated frequency.  
The disturbance power was determined according to clause 5.6 of EN 55013:2001+A1+A2. 
The disturbance power was measured at the following leads/ports:  
AC mains port, DC power port, Audio input port, Video output port and USB port.  
The maximum disturbance power at each frequency was found by moving the absorption 
clamp along the power or the signal lead. When testing video output leads, 75
 resistors 
were used as the load. When testing audio output/input leads, 10 k
 resistors were used as 
the load. 
Following figures are those disturbance power results measured at respective ports. 
Page of 33
Display

Click on the first or last page to see other GO PLAY MICRO (serv.man6) service manuals if exist.