Harman Kardon GO PLAY MICRO (serv.man6) EMC - CB Certificate ▷ View online
Produkte
Products
Products
Prüfbericht - Nr.:
Test Report No.:
15036107 001
Seite 5 von 33
Page 5 of 33
2
General Product Information
2.1
Product Function and Intended Use
The EUT (equipment under test) is a system speaker. For the further information, refer to
the user’s manual.
the user’s manual.
2.2
Ratings and System Details
Input (Adapter)
: AC 100-240V, 50/60Hz; 2.0A
Input (System
speaker)
speaker)
DC 24V, 2.3A
Protection class
: II
2.3
Independent Operation Modes
The basic independent mode of operation is continuously operating mode. Refer to the
user’s manual for further information.
user’s manual for further information.
2.4
Noise Generating and Noise Suppressing Parts
Refer to the circuit diagram for further information.
2.5
Submitted Documents
User’s manual, circuit diagram, component list, label and PCB layout.
Photo documentations, construction drawings etc. (Refer to the relevant safety report
15035698 001).
Photo documentations, construction drawings etc. (Refer to the relevant safety report
15035698 001).
Produkte
Products
Products
Prüfbericht - Nr.:
Test Report No.:
15036107 001
Seite 6 von 33
Page 6 of 33
3
Test Set-up and Operation Modes
3.1
Principle of Configuration Selection
Emission: The equipment under test (EUT) was configured to measure its highest possible
emission level. The test conditions were adapted accordingly in reference to the instructions
for use.
Refer to the related paragraph of this report.
emission level. The test conditions were adapted accordingly in reference to the instructions
for use.
Refer to the related paragraph of this report.
Immunity: The equipment under test (EUT) was configured to have its highest possible
susceptibility against the tested phenomena. The test conditions were adapted accordingly in
reference to the instructions for use.
Refer to the related paragraph of this report.
susceptibility against the tested phenomena. The test conditions were adapted accordingly in
reference to the instructions for use.
Refer to the related paragraph of this report.
3.2
Physical Configuration for Testing
Refer to the related paragraph of this report.
3.3
Test Operation and Test Software
Refer to the related paragraph of this report. No software was used.
3.4
Special Accessories and Auxiliary Equipment
During the test, an AC-DC adaptor was used to supply the sample (model: NU60-9240230-
13, rated input: AC 100-240V, 50/60Hz, 2.0A, rated output: DC 24V, 2.3A, manufacturer:
Jiangsu Leader Electronics Inc.). Tests only applicable to AC port were also performed with
this AC-DC adaptor used and test results were documented accordingly.
For the disturbance power measurement of the sample, when testing audio input leads, 10
k
13, rated input: AC 100-240V, 50/60Hz, 2.0A, rated output: DC 24V, 2.3A, manufacturer:
Jiangsu Leader Electronics Inc.). Tests only applicable to AC port were also performed with
this AC-DC adaptor used and test results were documented accordingly.
For the disturbance power measurement of the sample, when testing audio input leads, 10
k
Ω
resistors were used as the load; when testing video output leads, 75
Ω
resistors were used
as the load.
3.5
Countermeasures to achieve EMC Compliance
Refer to the circuit diagram of the sample for detailed information
.
Produkte
Products
Products
Prüfbericht - Nr.:
Test Report No.:
15036107 001
Seite 7 von 33
Page 7 of 33
4
Test Results E M I S S I O N
4.1
Harmonics on AC Mains
Result:
Passed
Test procedure
:
EN 61000-3-2:2006
Harmonic order
:
2 – 40
th
Frequency range
:
0 – 2kHz
According to Clause 7 of EN 61000-3-2:2006, there is no limit specified for equipment with
a rated power of 75W or less, other than lighting equipment. The rated power of the sample
is less than 75W. Therefore, the sample is deemed to meet the requirements of EN 61000-3-
2:2006 without actual testing.
Produkte
Products
Products
Prüfbericht - Nr.:
Test Report No.:
15036107 001
Seite 8 von 33
Page 8 of 33
4.2
Voltage Fluctuations on AC Mains
Result:
Passed
Date of testing
:
25.01.2010
Test procedure
:
EN 61000-3-3:1995+A1+A2
Ambient Condition
:
Temperature: 16
o
C; Relative Humidity: 60%
According to the characteristics of the sample, as specified by clause 5 of the basic standard,
following limits apply:
following limits apply:
−
the maximum relative voltage change d
max
, shall not exceed 4%.
The following tables are those measured by an automatic measuring system.
Table 2: Voltage fluctuations and flicker measurement results
dc
dmax
d(t)
Pst
Plt
Limits
N/A
4%
N/A
N/A
N/A
Result
-
0.111%
-
-
-