Prüfbericht - Nr.:
 
Test Report No.:
 
15036107 001
 
Seite 17 von 33 
Page 17 of 33 
 
 
Figure 7: Spectrum diagram and measurement results of disturbance power measurement 
results, USB port 
 
 
Note: due to that the preview test results with peak detector are far less than average limits, no final 
measurements were made with quasi-peak detector.
 
 
Average measurement results: 
Frequency 
MHz 
Average result 
(dBpW) 
Average limit 
(dBpW) 
Margin 
  (dB) 
30.312 
15.1 
35.0 
19.9 
 
 
 
 
 
Produkte 
Products
 
 
 
 
 
Prüfbericht - Nr.:
 
Test Report No.:
 
15036107 001
 
Seite 18 von 33 
Page 18 of 33 
 
 
5
 
 Test Results IMMUNITY 
 
During the immunity tests, the EUT was operated under conditions specified by clause 3.1 
of this report. 
Performance criterion A: The apparatus shall continue to operate as intended during the test. 
No change of actual operating state (for example change of channel) is allowed as a result of 
the application of the test. Multifunction equipment shall for each function meet the relevant 
requirements. Evaluation is carried out for audio and video functions. 
Performance criterion B: The equipment shall continue to operate as intended after the test. 
No  loss  of  function  is  allowed  after  the  test  when  the  apparatus  is  used  as  intended.  No 
change of actual operating state for example change of channel or stored data and settings is 
allowed as result of the application of the test. During the test, degradation of performance is 
allowed. 
Performance  criterion  C:  Temporary  loss  of  function  is  allowed,  provided  the  function  is 
self-recoverable or can be restored by the operation of the controls. 
During all the immunity tests, the sample was in its normal operating mode. 
 
      
Room temperature   
16°C 
Relative humidity 
 
58% 
 
 
 
Produkte 
Products
 
 
 
 
 
Prüfbericht - Nr.:
 
Test Report No.:
 
15036107 001
 
Seite 19 von 33 
Page 19 of 33 
 
 
5.1
 
Electrostatic Discharge 
Result: 
     Passed 
 
The  immunity  against  electrostatic  discharge  was  tested  in  accordance  with  clause  4.7  and 
table  15  of  EN  55020:2007.  Test  setup,  test  method  and  ESD  generator  are  in  accordance 
with IEC 61000-4-2. 
 
The EUT is placed on 0.8m wood table above the ground plane. And the minimum distance 
between  the  EUT  and  all  other  conductive  structures  except  the  ground  plane  beneath  the 
EUT is more than 0.5m. 
Date of testing 
:  27.01.2010  
Test level 
±
4.0kV (Contact Discharge), 
±
8.0kV (Air Discharge) 
Polarity 
:  Positive / negative 
Number of discharges 
:  10 for each polarity at each discharge point 
Performance criteria 
:  B 
Operation mode 
:  Continuously operating mode 
Table 3: Electrostatic discharge immunity test results  
Position 
Kind of Discharge 
Result 
Remarks 
Accessible metallic part 
of the EUT 
Contact discharge 
Pass 
After the test, the sample can 
operate as intended. 
HCP and VCP 
Contact discharge 
Pass 
After the test, the sample can 
operate as intended. 
Seams and slots around 
the enclosure and 
insulated plane 
Air discharge 
Pass 
After the test, the sample can 
operate as intended. 
Air gap of the switch 
Air discharge 
Pass 
After the test, the sample can 
operate as intended. 
 
 
 
 
Produkte 
Products
 
 
 
 
 
Prüfbericht - Nr.:
 
Test Report No.:
 
15036107 001
 
Seite 20 von 33 
Page 20 of 33 
 
 
5.2
 
Radio frequency electromagnetic field, keyed carrier 
Result: 
     Passed 
 
This  immunity  test  was  performed  in  accordance  with  clause  4.7  and  table  15  of  EN 
55020:2007. Test setup and test method are in accordance with IEC 61000-4-3. 
 
The test was performed inside a GTEM cell. The field uniformity of the volume where the 
sample was placed met the field uniformity requirements specified by IEC 61000-4-3. 
Date of testing 
27.01.2010  
Test specifications 
Table 15 of EN 55020:2007 
900 MHz, 3V/m, duty cycle 1/8, 217 Hz rep. frequency 
Performance criterion  : 
Operation mode 
Continuously operating mode 
 
Test
 
result: the sample can continue to operate correctly during the application of 
electromagnetic field. 