DOWNLOAD Harman Kardon GO AND PLAY (serv.man3) Service Manual ↓ Size: 3.09 MB | Pages: 80 in PDF or view online for FREE

Model
GO AND PLAY (serv.man3)
Pages
80
Size
3.09 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
go-and-play-sm3.pdf
Date

Harman Kardon GO AND PLAY (serv.man3) EMC - CB Certificate ▷ View online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
21 of 80 
 
4.7.  Electrostatic Discharge Immunity: IEC 61000-4-2: 1995/A1: 1998/A2: 2000 
 
This test simulates electrostatic events (similar to being “zapped” by touching a light switch) and evaluates the 
ability of the EUT to tolerate such events.  Testing was performed in accordance with IEC 61000-4-2.  
Tabletop devices are placed on an insulated mat on a horizontal coupling plane.  Air discharges and contact 
charges are made to the EUT on connectors and conducting surfaces (as illustrated in the Test Results section 
of this Test Report).  The discharges shall be applied in two ways: 
a)  Contact Discharges to the conductive surfaces and to coupling planes: 
The EUT shall be exposed to at least 200 discharges, 100 each at negative and positive polarity, at a 
minimum of four test pints (a minimum of 50 discharges at each point).  One of the test points shall be 
subjected to at least 50 indirect discharges (contact) to the center of the front edge of the horizontal-
coupling plane.  The remaining three test points shall each receive at least 50 direct contact discharges.  If 
no direct contact test points are available, then at least 200 indirect discharges shall be applied in the 
indirect mode.   
b)  Air Discharge at slots and apertures, and insulating surfaces: 
On those parts of the EUT where it is not possible to perform contact discharge testing, the equipment 
should be investigated to identify user accessible points where breakdown may occur.  This investigation 
should be restricted to those areas normally handled by the user.  A minimum of 10 single air discharges 
of each polarity and test level shall be applied to the selected test point for each area.   
 
For further information, please refer to the technical sections in the IEC 61000-4-2 publication in addition to 
the test results section and photographs of the test set-up provided in this report. 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
22 of 80 
 
Figure 4.   ESD Test Setup Diagram 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
N
OT TO 
S
CALE 
 
CONFIGURATION LEGEND 
 
1.  Test Laboratory (6 x 7 meters) 
2.  Vertical Conducting Wall (3 x 3 m, grounded) 
3.  Ground Plane (14 square meters) 
4.  Ground Rod extending 3 m under ground plane 
5.  Non-Conducting table for ESD Simulator Control Box 
6.  ESD Simulator Control Box on cart 
7.  Electro-Static Discharge (ESD) Gun (hand held, grounded to grounding rod) 
8.  DC power for devices 
9.  Ground strap with two 470kOhm resistors 
10. Grounding Strap 
11.  Horizontal Coupling Plane, grounded to Grounding Rod 
12. Insulating Mat 
13.  Vertical Coupling Plane 
14.  EUT and Associated System 
 
 
7
11
12 
10 
13 
14 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
23 of 80 
 
 
4.8.  Radio Frequency Immunity: IEC 61000-4-3: 2006 
 
This test bombards the EUT with electric fields that may couple into the system via chassis slots and interface 
cables and evaluates the product’s immunity.  Testing was performed in accordance with IEC 61000-4-3.  The 
RF immunity test entails subjecting the equipment under test to a uniform field of radiated electromagnetic 
energy of a specified field strength and frequency, and monitoring the functionality of the device as the 
frequency is swept over a specified frequency range.   
 
The EUT is set up inside a shielded, semi-anechoic chamber with a radiating antenna at a distance of 3 meters 
from the EUT.  For further information, please refer to the technical sections in the IEC 61000-4-3 publication 
in addition to the test results section and photographs of the test set-up provided in this report. 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
24 of 80 
 
Figure 5.   Radio Frequency Immunity Test Setup Diagram 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOT TO SCALE 
 
 
CONFIGURATION LEGEND 
 
1. Test 
laboratory 
2.  Shielded anechoic chamber 
3.  Power Line filters and power distribution breaker box 
4.  Power strip for EUT and peripherals 
5. Transmit 
antennas 
6. E-Field 
sensor 
7.  Monitoring camera for EUT 
8.  Broadband power amplifiers 
9.  E-Field probe monitoring system 
10. Signal Generators 
11. Non-Conducting table 
12.  EUT and Associated System 
 
3 m 
10 
11 
12 
Page of 80
Display