Harman Kardon GO AND PLAY (serv.man3) EMC - CB Certificate ▷ View online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
21 of 80
4.7. Electrostatic Discharge Immunity: IEC 61000-4-2: 1995/A1: 1998/A2: 2000
This test simulates electrostatic events (similar to being “zapped” by touching a light switch) and evaluates the
ability of the EUT to tolerate such events. Testing was performed in accordance with IEC 61000-4-2.
Tabletop devices are placed on an insulated mat on a horizontal coupling plane. Air discharges and contact
charges are made to the EUT on connectors and conducting surfaces (as illustrated in the Test Results section
of this Test Report). The discharges shall be applied in two ways:
a) Contact Discharges to the conductive surfaces and to coupling planes:
The EUT shall be exposed to at least 200 discharges, 100 each at negative and positive polarity, at a
minimum of four test pints (a minimum of 50 discharges at each point). One of the test points shall be
subjected to at least 50 indirect discharges (contact) to the center of the front edge of the horizontal-
coupling plane. The remaining three test points shall each receive at least 50 direct contact discharges. If
no direct contact test points are available, then at least 200 indirect discharges shall be applied in the
indirect mode.
The EUT shall be exposed to at least 200 discharges, 100 each at negative and positive polarity, at a
minimum of four test pints (a minimum of 50 discharges at each point). One of the test points shall be
subjected to at least 50 indirect discharges (contact) to the center of the front edge of the horizontal-
coupling plane. The remaining three test points shall each receive at least 50 direct contact discharges. If
no direct contact test points are available, then at least 200 indirect discharges shall be applied in the
indirect mode.
b) Air Discharge at slots and apertures, and insulating surfaces:
On those parts of the EUT where it is not possible to perform contact discharge testing, the equipment
should be investigated to identify user accessible points where breakdown may occur. This investigation
should be restricted to those areas normally handled by the user. A minimum of 10 single air discharges
of each polarity and test level shall be applied to the selected test point for each area.
On those parts of the EUT where it is not possible to perform contact discharge testing, the equipment
should be investigated to identify user accessible points where breakdown may occur. This investigation
should be restricted to those areas normally handled by the user. A minimum of 10 single air discharges
of each polarity and test level shall be applied to the selected test point for each area.
For further information, please refer to the technical sections in the IEC 61000-4-2 publication in addition to
the test results section and photographs of the test set-up provided in this report.
the test results section and photographs of the test set-up provided in this report.
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
22 of 80
Figure 4. ESD Test Setup Diagram
N
OT TO
S
CALE
CONFIGURATION LEGEND
1. Test Laboratory (6 x 7 meters)
2. Vertical Conducting Wall (3 x 3 m, grounded)
3. Ground Plane (14 square meters)
4. Ground Rod extending 3 m under ground plane
5. Non-Conducting table for ESD Simulator Control Box
6. ESD Simulator Control Box on cart
7. Electro-Static Discharge (ESD) Gun (hand held, grounded to grounding rod)
8. DC power for devices
9. Ground strap with two 470kOhm resistors
10. Grounding Strap
11. Horizontal Coupling Plane, grounded to Grounding Rod
12. Insulating Mat
13. Vertical Coupling Plane
14. EUT and Associated System
1
2
3
4
6
7
5
8
9
11
12
10
13
14
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
23 of 80
4.8. Radio Frequency Immunity: IEC 61000-4-3: 2006
This test bombards the EUT with electric fields that may couple into the system via chassis slots and interface
cables and evaluates the product’s immunity. Testing was performed in accordance with IEC 61000-4-3. The
RF immunity test entails subjecting the equipment under test to a uniform field of radiated electromagnetic
energy of a specified field strength and frequency, and monitoring the functionality of the device as the
frequency is swept over a specified frequency range.
The EUT is set up inside a shielded, semi-anechoic chamber with a radiating antenna at a distance of 3 meters
from the EUT. For further information, please refer to the technical sections in the IEC 61000-4-3 publication
in addition to the test results section and photographs of the test set-up provided in this report.
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
24 of 80
Figure 5. Radio Frequency Immunity Test Setup Diagram
NOT TO SCALE
CONFIGURATION LEGEND
1. Test
laboratory
2. Shielded anechoic chamber
3. Power Line filters and power distribution breaker box
4. Power strip for EUT and peripherals
5. Transmit
3. Power Line filters and power distribution breaker box
4. Power strip for EUT and peripherals
5. Transmit
antennas
6. E-Field
sensor
7. Monitoring camera for EUT
8. Broadband power amplifiers
9. E-Field probe monitoring system
10. Signal Generators
11. Non-Conducting table
12. EUT and Associated System
8. Broadband power amplifiers
9. E-Field probe monitoring system
10. Signal Generators
11. Non-Conducting table
12. EUT and Associated System
1
3
3 m
2
4
5
7
8
9
10
11
12
6
Click on the first or last page to see other GO AND PLAY (serv.man3) service manuals if exist.