Harman Kardon GO AND PLAY (serv.man3) EMC - CB Certificate ▷ View online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
29 of 80
4.11. Radio Frequency Conducted Common Mode Immunity: IEC 61000-4-6
This test injects a disturbance directly onto AC/DC power and signal I/O cables. Testing was performed in
accordance with IEC 61000-4-6. The standard configuration as outlined in the IEC 61000-4-6 was used. For
further information, please refer to the technical sections of the IEC 61000-4-6 publication in addition to the
test results section and photographs of the test set-up provided in this report.
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
30 of 80
Figure 8. RF Common Mode Immunity Test Setup Diagram
NOT TO SCALE
CONFIGURATION LEGEND
1. Test
Laboratory
2. DC power for EUT
3. Ground
3. Ground
Plane
4. 10cm wooden Platform
5. Test
5. Test
Generator
6. Current
Probe
7. Coupling/Decoupling
Network
8. Coupling/Decoupling
Network
9. EUT
10. Associated System
1
2
9
6
5
7
10
3
4
8
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
31 of 80
4.12. Power Frequency Magnetic Field Immunity: IEC 61000-4-8: 1993/A1: 2000
This test subjects devices to the fields produced by current carrying conductors of standard building power.
Testing was performed in accordance with IEC 61000-4-8. The standard configuration as outlined in IEC
61000-4-8 was used. For further information, please refer to the technical sections of IEC 61000-4-8 in
addition to the test results section and photographs of the test set-up provided in this report.
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
32 of 80
Figure 9. Power Frequency Magnetic Field Immunity Test Setup
NOT TO SCALE
CONFIGURATION LEGEND
1. Test
laboratory
2. AC Power for devices
3. AC Power Supply
4. AC Power for EUT
5. Helmholtz
3. AC Power Supply
4. AC Power for EUT
5. Helmholtz
Coil
6. Non-Conductive
Table
7. EUT
1
2
3
5
6
7
4