August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
29 of 80 
 
4.11.  Radio Frequency Conducted Common Mode Immunity: IEC 61000-4-6 
 
This test injects a disturbance directly onto AC/DC power and signal I/O cables.  Testing was performed in 
accordance with IEC 61000-4-6.  The standard configuration as outlined in the IEC 61000-4-6 was used.  For 
further information, please refer to the technical sections of the IEC 61000-4-6 publication in addition to the 
test results section and photographs of the test set-up provided in this report. 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
30 of 80 
 
Figure 8.   RF Common Mode Immunity Test Setup Diagram  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOT TO SCALE 
 
CONFIGURATION LEGEND 
 
1. Test 
Laboratory 
2.  DC power for EUT  
3. Ground 
Plane 
4.  10cm wooden Platform 
5. Test 
Generator 
6. Current 
Probe 
7. Coupling/Decoupling 
Network 
8. Coupling/Decoupling 
Network 
9. EUT 
 
10. Associated System 
 
7
10
8
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
31 of 80 
 
 
4.12.  Power Frequency Magnetic Field Immunity: IEC 61000-4-8: 1993/A1: 2000 
 
This test subjects devices to the fields produced by current carrying conductors of standard building power.  
Testing was performed in accordance with IEC 61000-4-8.  The standard configuration as outlined in IEC 
61000-4-8 was used.  For further information, please refer to the technical sections of IEC 61000-4-8 in 
addition to the test results section and photographs of the test set-up provided in this report. 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
32 of 80 
 
Figure 9.  Power Frequency Magnetic Field Immunity Test Setup 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
NOT TO SCALE 
 
 
CONFIGURATION LEGEND 
 
1. Test 
laboratory 
2.  AC Power for devices 
3.  AC Power Supply 
4.  AC Power for EUT 
5. Helmholtz 
Coil 
6. Non-Conductive 
Table 
7. EUT 
 
3
5
7
Page of 80