Harman Kardon GO AND PLAY (serv.man3) EMC - CB Certificate ▷ View online
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
5 of 80
CERTIFICATION
The compatibility testing and this report have been prepared by Nemko USA, Inc., an independent
electromagnetic compatibility consulting and test laboratory.
Testing and data collection were accomplished in accordance with the test methods listed in this report.
I certify the data evaluation and equipment configuration herein to be a true and accurate representation of the
sample's test characteristics, as of the test date(s), and for the design of the test sample utilized to compile this
report.
Michael T. Krumweide
EMC Supervisor
EMC Supervisor
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
6 of 80
1. ADMINISTRATIVE DATA AND TEST SUMMARY
1.1. Administrative Data
CLIENT: Harman
Multimedia
8500 Balboa Blvd.
Northridge, CA 91329
818.830.8737
Northridge, CA 91329
818.830.8737
CONTACT: Bruce
Ryan
DATE (S) OF TEST:
July 19, 2006 to August 7, 2006
EQUIPMENT UNDER TEST (EUT):
Audio/Peripheral System
Model
Go + Play
Model name was changed from “Vista” to Go + Play at the
completion of testing. Test setup photos does reflect the
name change.
completion of testing. Test setup photos does reflect the
name change.
Condition Upon Receipt
Suitable for Test
TEST SPECIFICATION:
Radio Frequency Emissions in accordance with requirements
of EN 55022: 1998/A1: 2000/A2: 2003 and FCC Part 15B.
Electromagnetic Immunity tests in accordance with
requirements of EN 55024: 1998/A1: 2001/A2: 2003
Electromagnetic Immunity tests in accordance with
requirements of EN 55024: 1998/A1: 2001/A2: 2003
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
7 of 80
1.2. Test Summary
1.2.1. Emissions Test Summary
Test Methods
Frequency Range
Compliance Status
FCC 15B, Sec. 107, Class “B ”
Conducted Emissions
Conducted Emissions
0.15 MHz – 30 MHz
PASS
FCC 15B, Sec. 109, Class “B”
Radiated Emissions
Radiated Emissions
30 MHz –1000MHz
PASS
VCCI, V-3/2006.04,
Normative Annex 1, Class “B”
Conducted Emissions
Normative Annex 1, Class “B”
Conducted Emissions
0.15 MHz – 30 MHz
PASS
VCCI, V-3/2006.04,
Normative Annex 1, Class “B”
Radiated Emissions
Normative Annex 1, Class “B”
Radiated Emissions
30 MHz – 1000 MHz
PASS
EN 55022: 1998/A1: 2000/A2:
2003, Class “B”
Conducted Emissions
2003, Class “B”
Conducted Emissions
0.15 MHz – 30 MHz
PASS
EN 55022: 1998/A1: 2000/A2:
2003, Class “B”
Telecom Conducted Emissions
2003, Class “B”
Telecom Conducted Emissions
0.15 MHz – 30 MHz
N/A
EN 55022: 1998/A1: 2000/A2:
2003, Class “B”
Radiated Emissions
2003, Class “B”
Radiated Emissions
30 MHz – 1000 MHz
PASS
EN 61000-3-2: 2000/A2: 2005
Power Line Harmonics
up to the 40
th
Harmonic
PASS
EN 61000-3-3: 1995/A1:
2001Power Line Flicker
2001Power Line Flicker
less than or equal to
4% Maximum Relative
Voltage Change; Value of D(T)
less than or equal
to
3% for more than 200 Ms
PASS
Test Supervisor:
Mike Krumweide, Nemko USA, Inc.
Nemko USA, Inc.
11696 Sorrento Valley Road, Suite F, San Diego, CA 92121
Phone (858) 755-5525 Fax (858) 452-1810
DATE
DOCUMENT NAME
DOCUMENT #
PAGE
August 10, 2006
Harman Multimedia Go + Play EMC Test Report
2006 060635 EMC
8 of 80
1.2.2. Immunity Test Summary
Test Methods
Minimum Criterion
Level Required
as per EN 55024
Criterion Level
Tested
Compliance
Status
IEC 61000-4-2: 1995/A1:
1998/A2: 2000
1998/A2: 2000
- ESD Immunity
Criterion B
±8 kV air discharge,
±4 kV contact discharge
Criterion B
±8 kV Air Discharge,
±4 kV Contact Discharge
PASS
IEC 61000-4-3: 2006 -
Radio Frequency
Immunity
Immunity
Criterion A
3 V/m from 80-1000 MHz
(80% AM at 1kHz)
Criterion A
3 V/m from 80-1000 MHz
(80% AM at 1kHz)
PASS
IEC 61000-4-4: 2004
-Electrical Fast Transient
-Electrical Fast Transient
Immunity
Criterion B
Power line pulses of ± 1 kV;
I/O line pulses of ± 0.5 kV
Criterion B
Power Line Pulses of ± 1 kV;
up to ±2kV process/control lines;
I/O Line Pulses of ± 0.5 kV
PASS
IEC 61000-4-5: 2005
-Surge Immunity
-Surge Immunity
Criterion B
±2kV common mode surges,
±1kV differential mode surges
Criterion B
±2kV Common Mode Surges,
±1kV Differential Mode
Surges
PASS
IEC 61000-4-6: 2003/A1:
2004/A2: 2006
-RF Common Mode
2004/A2: 2006
-RF Common Mode
Immunity
Criterion A
150 kHz - 80 MHz at 3 Vrms
1 kHz 80% amplitude modulated
Criterion A
150 kHz - 80 MHz at 3 Vrms
1kHz 80% amplitude modulated
PASS
IEC 61000-4-8: 1993/A1:
2000
Power Frequency Magnetic
Field
Field
Criterion A
Helmholtz coil at 50 Hz,
to 1 Amp (rms) per meter
Criterion A
Helmholtz coil at 50 Hz,
to 1 Amp (rms) per meter
PASS
IEC 61000-4-11: 2004
- Voltage Dips and Short
- Voltage Dips and Short
Interruptions
Criterion B and C
Voltage Dips of 30% and >95%;
Interruptions of >95%.
Criterion B and C
Voltage Dips of 30% and
>95%; Interruptions of >95%.
PASS
Test Supervisor:
Mike Krumweide, Nemko USA, Inc.
Refer to the test results section for further details.