DOWNLOAD Harman Kardon GO AND PLAY (serv.man3) Service Manual ↓ Size: 3.09 MB | Pages: 80 in PDF or view online for FREE

Model
GO AND PLAY (serv.man3)
Pages
80
Size
3.09 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
go-and-play-sm3.pdf
Date

Harman Kardon GO AND PLAY (serv.man3) EMC - CB Certificate ▷ View online

Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
5 of 80 
 
 
CERTIFICATION 
 
The compatibility testing and this report have been prepared by Nemko USA, Inc., an independent 
electromagnetic compatibility consulting and test laboratory.   
 
Testing and data collection were accomplished in accordance with the test methods listed in this report. 
 
I certify the data evaluation and equipment configuration herein to be a true and accurate representation of the 
sample's test characteristics, as of the test date(s), and for the design of the test sample utilized to compile this 
report. 
 
 
Michael T. Krumweide 
EMC Supervisor 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
6 of 80 
 
1.  ADMINISTRATIVE DATA AND TEST SUMMARY 
1.1. Administrative Data 
 
CLIENT: Harman 
Multimedia
 
8500 Balboa Blvd. 
Northridge, CA  91329 
818.830.8737  
 
 
CONTACT: Bruce 
Ryan 
 
DATE (S) OF TEST: 
July 19, 2006 to August 7, 2006 
 
EQUIPMENT UNDER TEST (EUT): 
Audio/Peripheral System 
 
 
Model 
Go + Play 
 
 
Model name was changed from “Vista” to Go + Play at the 
completion of testing.  Test setup photos does reflect the 
name change. 
 
 
Condition Upon Receipt 
Suitable for Test 
 
TEST SPECIFICATION: 
Radio Frequency Emissions in accordance with requirements 
of EN 55022: 1998/A1: 2000/A2: 2003 and FCC Part 15B. 
Electromagnetic Immunity tests in accordance with 
requirements of EN 55024: 1998/A1: 2001/A2: 2003 
 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
7 of 80 
 
1.2. Test Summary 
1.2.1.  Emissions Test Summary 
 
Test Methods 
Frequency Range 
Compliance Status 
FCC 15B, Sec. 107, Class “B ” 
Conducted Emissions  
0.15 MHz – 30 MHz  
PASS 
FCC 15B, Sec. 109, Class “B” 
Radiated Emissions  
30 MHz –1000MHz  
PASS 
VCCI, V-3/2006.04, 
Normative Annex 1, Class “B” 
Conducted Emissions  
0.15 MHz – 30 MHz  
PASS 
VCCI, V-3/2006.04, 
Normative Annex 1, Class “B” 
Radiated Emissions  
30 MHz – 1000 MHz  
PASS 
EN 55022: 1998/A1: 2000/A2: 
2003, Class “B” 
Conducted Emissions  
0.15 MHz – 30 MHz  
PASS 
EN 55022: 1998/A1: 2000/A2: 
2003, Class “B” 
Telecom Conducted Emissions  
0.15 MHz – 30 MHz  
N/A 
EN 55022: 1998/A1: 2000/A2: 
2003, Class “B” 
Radiated Emissions  
30 MHz – 1000 MHz  
PASS 
EN 61000-3-2: 2000/A2: 2005 
Power Line Harmonics 
up to the 40
th
 Harmonic 
PASS 
EN 61000-3-3: 1995/A1: 
2001Power Line Flicker 
less than or equal to
 4% Maximum Relative 
Voltage Change;  Value of D(T) 
less than or equal 
to
 3% for more than 200 Ms 
PASS 
 
 
 
Test Supervisor: 
 
Mike Krumweide, Nemko USA, Inc. 
Nemko USA, Inc. 
11696 Sorrento Valley Road, Suite F, San Diego, CA  92121 
Phone (858) 755-5525  Fax (858) 452-1810 
DATE 
DOCUMENT NAME 
DOCUMENT # 
PAGE 
August 10, 2006 
Harman Multimedia  Go + Play  EMC Test Report 
2006 060635 EMC 
8 of 80 
 
 
1.2.2.  Immunity Test Summary 
 
 
Test Methods 
 
Minimum Criterion  
Level Required  
as per EN 55024 
 
Criterion Level 
Tested 
Compliance 
Status 
IEC 61000-4-2: 1995/A1: 
1998/A2: 2000
 
- ESD Immunity 
Criterion B 
±8 kV air discharge,  
±4 kV contact discharge 
Criterion B 
±8 kV Air Discharge,  
±4 kV Contact Discharge 
PASS 
IEC 61000-4-3: 2006 -
Radio Frequency 
Immunity 
Criterion A  
3 V/m from 80-1000 MHz  
(80% AM at 1kHz) 
Criterion A  
3 V/m from 80-1000 MHz  
(80% AM at 1kHz) 
PASS 
IEC 61000-4-4: 2004 
-Electrical Fast Transient 
Immunity 
Criterion B 
Power line pulses of ± 1 kV; 
I/O line pulses of ± 0.5 kV 
Criterion B 
Power Line Pulses of ± 1 kV; 
up to ±2kV process/control lines; 
I/O Line Pulses of ± 0.5 kV 
PASS 
IEC 61000-4-5: 2005 
-Surge Immunity 
Criterion B 
±2kV common mode surges, 
±1kV differential mode surges 
Criterion B 
±2kV Common Mode Surges,  
±1kV Differential Mode 
Surges 
PASS 
IEC 61000-4-6: 2003/A1: 
2004/A2: 2006 
-RF Common Mode 
Immunity 
Criterion A 
150 kHz - 80 MHz at 3 Vrms 
1 kHz 80% amplitude modulated 
Criterion A 
150 kHz - 80 MHz at 3 Vrms 
1kHz 80% amplitude modulated 
PASS 
IEC 61000-4-8: 1993/A1: 
2000
 
Power Frequency Magnetic 
Field 
Criterion A 
Helmholtz coil at 50 Hz, 
to 1 Amp (rms) per meter 
Criterion A 
Helmholtz coil at 50 Hz, 
to 1 Amp (rms) per meter 
PASS 
IEC 61000-4-11: 2004 
- Voltage Dips and Short 
Interruptions 
Criterion B and C 
Voltage Dips of 30% and >95%; 
Interruptions of >95%. 
Criterion B and C 
Voltage Dips of 30% and 
>95%; Interruptions of >95%. 
PASS 
 
 
 
Test Supervisor
 
Mike Krumweide, Nemko USA, Inc. 
Refer to the test results section for further details
Page of 80
Display