Harman Kardon DVD 30 EMC - CB Certificate ▷ View online
Test report no. 305945I
Page 11 (12)
6.6 Test equipment
Equipment
Equipment
Manufacturer
Type
SEMKO No.
Software RSUS
RSUS,
Version
2.119
Signal generator:
Rohde & Schwarz SMY 01
7831
RF Power Meter:
Rohde & Schwarz NRVD
7860
Power Head:
Rohde & Schwarz NRV-Z31
7473
Power Head:
Rohde & Schwarz NRV-Z31
7411
Amplifier 220 - 1000 MHz:
Amplifier Research 200 W1000M7
7857
Transmitting antenna
26 - 1000 MHz:
26 - 1000 MHz:
EMCO
3143
7855
6.7 Test protocol
Date of test: 10 June, 2003
Test
No.
Freq.
[MHz]
Level
[V/m]
Pol.
V/H
Operating mode/
Exposed side
Pass/
Fail
Comment
1 895-905 3 V
Front
Pass
-
2 895-905 3 H
Front
Pass
-
3 895-905 3 V
Rear
Pass
-
4 895-905 3 H
Rear
Pass
-
Test report no. 305945I
Page 12 (12)
7. IMMUNITY TO BURST, EN 61000-4-4
7.1 Operating environment
Temperature: 21
7.1 Operating environment
Temperature: 21
°C
Relative Humidity:
49 %
7.2 Test set-up
The EUT was placed on a non-metallic table 0,8 m above a reference ground plane (RGP) and was put into
operation according to the specified operating mode.
7.3 Test conditions
Test level:
1,0 kV
AC-power port
Performance criterion:
B
Repetition rate:
5 kHz
Application method:
AC mains - Coupling/decoupling network, (CDN)
Duration of each test:
1 min
Ports for test:
AC-power
EUT- position:
Table top
7.4 Measurement uncertainty
The uncertainty of the applied fast transient/burst is within the tolerance specified by the standard.
7.5 Test equipment
Equipment
Manufacturer
Type
SEMKO No.
Test generator including CDN:
Haefely
PEFT Test system
5644
Software: Haefely
WinPats,
Version
3.15
Reference ground plane
Aluminium 4,0 m x 2,5 m x 1,5 mm
7.6 Test protocol
Date of test: 10 June, 2003
Test
No.
Level
[kV]
Polarity
+/-
Line/Cable Coupling
Device
Pass/
Fail
Comment
1 1 +
AC-power
(L/N
/
) CDN
Pass -
2 1 -
AC-power
(L/N
/
) CDN
Pass Not.1
Not.1 short horizontal rules came up during the test, but the function of the EUT was not disturbed.
Test report no. 305945I
Page 12 (12)
7. IMMUNITY TO BURST, EN 61000-4-4
7.1 Operating environment
Temperature: 21
7.1 Operating environment
Temperature: 21
°C
Relative Humidity:
49 %
7.2 Test set-up
The EUT was placed on a non-metallic table 0,8 m above a reference ground plane (RGP) and was put into
operation according to the specified operating mode.
7.3 Test conditions
Test level:
1,0 kV
AC-power port
Performance criterion:
B
Repetition rate:
5 kHz
Application method:
AC mains - Coupling/decoupling network, (CDN)
Duration of each test:
1 min
Ports for test:
AC-power
EUT- position:
Table top
7.4 Measurement uncertainty
The uncertainty of the applied fast transient/burst is within the tolerance specified by the standard.
7.5 Test equipment
Equipment
Manufacturer
Type
SEMKO No.
Test generator including CDN:
Haefely
PEFT Test system
5644
Software: Haefely
WinPats,
Version
3.15
Reference ground plane
Aluminium 4,0 m x 2,5 m x 1,5 mm
7.6 Test protocol
Date of test: 10 June, 2003
Test
No.
Level
[kV]
Polarity
+/-
Line/Cable Coupling
Device
Pass/
Fail
Comment
1 1 +
AC-power
(L/N
/
) CDN
Pass -
2 1 -
AC-power
(L/N
/
) CDN
Pass Not.1
Not.1 short horizontal rules came up during the test, but the function of the EUT was not disturbed.
Test report no. 305945I
Page 12 (12)
7. IMMUNITY TO BURST, EN 61000-4-4
7.1 Operating environment
Temperature: 21
7.1 Operating environment
Temperature: 21
°C
Relative Humidity:
49 %
7.2 Test set-up
The EUT was placed on a non-metallic table 0,8 m above a reference ground plane (RGP) and was put into
operation according to the specified operating mode.
7.3 Test conditions
Test level:
1,0 kV
AC-power port
Performance criterion:
B
Repetition rate:
5 kHz
Application method:
AC mains - Coupling/decoupling network, (CDN)
Duration of each test:
1 min
Ports for test:
AC-power
EUT- position:
Table top
7.4 Measurement uncertainty
The uncertainty of the applied fast transient/burst is within the tolerance specified by the standard.
7.5 Test equipment
Equipment
Manufacturer
Type
SEMKO No.
Test generator including CDN:
Haefely
PEFT Test system
5644
Software: Haefely
WinPats,
Version
3.15
Reference ground plane
Aluminium 4,0 m x 2,5 m x 1,5 mm
7.6 Test protocol
Date of test: 10 June, 2003
Test
No.
Level
[kV]
Polarity
+/-
Line/Cable Coupling
Device
Pass/
Fail
Comment
1 1 +
AC-power
(L/N
/
) CDN
Pass -
2 1 -
AC-power
(L/N
/
) CDN
Pass Not.1
Not.1 short horizontal rules came up during the test, but the function of the EUT was not disturbed.