Test report no. 305945E
Page 9 (14)
 
 
 
6.5 Test protocol 
 
Date of test: 4 June,2003 
 
Measurements were made on all in- and outputs, and mains lead. 
 
DVD-mode 
 
Disturbance level 
dB(pW) 
Mains lead 
Phones 
 
Permitted limit 
dB(pW) 
 
Frequency 
(MHz) 
QP AV QP AV QP AV 
77,9  33 27 *  * 47 37 
126,0  *  *  32 30 49 39 
138,9  *  *  32 31 49 39 
145,6  *  *  32 31 49 39 
 
* No disturbances closer to the limit than 10dB(pW) were found. 
 
 
 
 
 
 
 
 
 
Test report no. 305945E
Page 10 (14)
 
7.   DISTURBANCE RADIATION DUE TO ALL OTHER SOURCES 
 
IN THE FREQUENCY RANGE 30 MHZ TO 1000 MHZ 
 
 
7.1 Operating environment 
 
Temperature: 21 
°C 
Relative Humidity: 
48  % 
 
Measurements were performed in a semi-anechoic chamber. 
 
 
7.2 Test set-up and test procedure 
 
The EUT was positioned in order to emit maximum disturbance. 
 
Photos of test setup.  
 
 
 
 
 
An overview sweep with peak detection of the electric field intensity was performed in a semi-anechoic 
chamber. The overview sweep was performed with the measurement receiver in max-hold and the antenna 
was varied between 1 to 4 m in both horizontal and vertical polarisation. The measurements were repeated 
with the EUT rotated in 45-degree steps. 
 
The radiated disturbance electric field intensity was measured at a distance of 3 m and the EUT was placed 
on a non-metallic table, 0,8 m above the reference ground plane. 
 
 
Test report no. 305945E
Page 11 (14)
 
 
7.3 Measurement uncertainty 
 
Radiated disturbance electric field intensity, 80-300 MHz: 
±4,6 dB 
Radiated disturbance electric field intensity, 200-1000 MHz: 
±4,8 dB 
 
The measurement uncertainty describes the overall uncertainty of the given measured value during 
operation of the EUT in the above-mentioned way. 
 
Measurement uncertainty is calculated in accordance with EA-4 /02:1997. 
The measurement uncertainty is given with a confidence of 95%. 
 
 
7.4 Test equipment 
 
Test site: 
Semi-anechoic shielded chamber. 10 x 20 x 8,5 m ( W x L x H ). 
 
Equipment Manufacturer 
Type  SEMKO 
No. 
 
Software 
Rohde & Schwarz  ES-K1, version 1.60 
Test receiver 
Rohde & Schwarz  ESAI 
2973/2974 
Preamplifier SEMKO 
7992/7993 
Antenna, bilog 
Chase 
CBL6111A 
971 
 
 
 
Test report no. 305945E
Page 12 (14)
 
7.5 Test protocol 
 
Date of test: 5 June,2003 
 
An overview sweep performed with a peak detector is included in the test report, see below. 
 
 
Radiated electromagnetic field. 
 
 
 
 
0
10
20
30
40
50
60
70
80
Level [dBµV/m]
30M 40M 50M
70M
100M
200M
300M 400M
600M
1G
Frequency [Hz]