Harman Kardon DVD 30 EMC - CB Certificate ▷ View online

 
Test report no. 305945I
Page 3 (12)
 
1. CLIENT 
INFORMATION 
 
The EUT has been tested by request of: 
 
Company: 
Harman Consumer Group 
250 Crossways Park Drive 
Woodbury, NY 11797-2015 
USA 
Name of contact: 
Peter Philips 
Telephone: 
+1 516 682 6460 
Telefax: 
+1 516 682 3513 
 
 
2.  EQUIPMENT UNDER TEST (EUT) 
 
2.1 Identification of the EUT 
 
Equipment: DVD 
Player 
Type/model: DVD 
30 
Brand name: 
harman/kardon 
Serial number: 
Manufacturer: Harman Consumer Group 
Country of origin: 
USA 
Rating:  
100-240V AC, 50/60Hz, 20W 
Class II 
 
 
2.2 Additional information about the EUT 
 
The EUT consists of the following units: 
 
Unit: Type: 
DVD Player 
DVD 30 
Remote Control 
DVD 30 
 
 
The EUT was tested with the following cables: 
 
Cable: Type: 
Lenght: 
AC-power cable 
Standard two core 
1,6 m 
Audio 
Coaxial RG 58 C/U 50 Ohm 
2,5 m 
 
 
Test report no. 305945I
Page 4 (12)
 
3. TEST 
SPECIFICATIONS 
 
3.1 Standards 
 
EN 55 020 (1994) and Amendments A11(1996), A12(1999), A13(1999) and A14(1999): Electromagnetic 
immunity of broadcast receivers and associated equipment. 
 
The equipment has no external power connection or connection facility for external antenna and therefore 
testing has only been performed according to Amendment A12 (1999). 
 
Amendment A12 refers to the following basic standards: 
 
 
EN 61000-4-2 (1995) and A1(1995):  Electrostatic discharge immunity test. 
 
Required test level: 
Air discharge 8 kV, contact discharge 4 kV. 
 
 
EN 61000-4-3 (1996): 
Radiated, radio-frequency, electromagnetic field immunity test. 
 
Required test level: 
895-905 MHz, 3 V/m, 50 % duty cycle, 200 Hz rep. frequency. 
 
 
EN 61000-4-4 (1995): 
Electrical fast transient/burst requirements. 
 
Required test level: 
1,0 kV AC supply. 
 
 
3.2 Additions, deviations and exclusions from standards and accreditation 
 
No additions, deviations or exclusions have been made from standard. 
All tests performed are within the scope of the accreditation. 
 
 
3.3 Mode of operation during the test 
 
During the test the EUT was operating in the following mode: 
 
The DVD-player was playing a test DVD disc. 
 
 
 
 
 
Test report no. 305945I
Page 5 (12)
 
3.4 Performance criteria 
 
The performance criteria are based on the general criteria in the standard.  
 
Performance criteria 
 
Criterion A: 
The equipment shall continue to operate as intended during the test. No change of actual 
 
operating state (see below), is allowed as a result of the application of the test. 
 
Criterion B: 
The equipment shall continue to operate as intended after the test. No loss of function is 
 
allowed after the test when the apparatus is used as intended. No change of actual  
 
operating state (see below) is allowed as a result of the application of the test.  
 
During the test, degradation of performance is allowed. 
 
Change of actual operating state of the EUT: 
 
Playback is interrupted in DVD-mode. 
 
 
3.5 Performance verification 
 
The test engineer observed the performance of the EUT directly or via video cameras. 
 
The audio and video performance was checked via a television set, and the EUT was connected to the 
television set. 
 
 
4. TEST 
SUMMARY 
 
The results in this report apply only to sample tested: 
 
Test Result 
 
Note 
EN 61000-4-2: Electrostatic discharge 
Pass 
EN 61000-4-3: Radiated electromagnetic field 
Pass 
EN 61000-4-4: Electrical fast transients 
Pass 
 
 
 
Test report no. 305945I
Page 6 (12)
 
5. IMMUNITY 
TO 
ELECTROSTATIC 
DISCHARGE, EN 61 000-4-2 
 
5.1 Operating environment 
 
Temperature: 23 
°C 
Relative Humidity: 
42  % 
 
 
5.2 Test set-up 
 
A horizontal coupling plane (HCP) was placed on a non-metallic table 0,8 m above a reference ground plane 
(RGP) and connected to it with a cable with two 470 k
Ω resistors. The EUT was placed on an insulation 
sheet on the HCP and was operating according to the specified operating mode. 
 
A vertical coupling plane (VCP) was connected to the RGP with a cable with two 470 k
Ω resistors. 
 
 
5.3 Test conditions 
 
Test level: 
4 kV Contact discharge 
 
8 kV Air discharge 
 
Number of discharges at each point:  10 of each polarity 
 
Performance criterion: 
 
EUT position: 
Table top 
 
The selected test points are listed in this table, the numbers refer to the photo next page. 
 
Point Description 
VCP 1  0,1 m from the front of the EUT 
VCP 2  0,1 m from the back of the EUT 
VCP 3  0,1 from the right of the EUT 
VCP 4  0,1 from the left side of the EUT 
HCP 1  0,1 m from the front of the EU 
HCP 2  0,1 m from the back of the EUT 
HCP 3  0,1 from the right of the EUT 
HCP 4  0,1 from the left side of the EUT 
Rear side in- and outlets with reachable metal  
Rear side in- and outlets and cover 
Front side display, control buttons, phones and 
cover 
 
Contact discharges were applied to the VCP and the HCP. 
 
 
 
 
 
Page of 30