Harman Kardon DVD 25 EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 5 of 32 -
Order No. 200225249
Standardized approval marks
N
1
SCOPE
According to standards mentioned.
P
2
DEFINITIONS
According to standards mentioned.
P
3
GENERAL REQUIREMENTS
According to standards mentioned.
P
Safety class of the apparatus
Class II
P
4
GENERAL CONDITIONS FOR
TESTS
TESTS
According to standards mentioned.
P
4.1.4
Ventilation instructions require the
use of the test box
use of the test box
With all user controls set to obtain maximum power from
the mains. Apparatus positioned according to instruction
for use.
the mains. Apparatus positioned according to instruction
for use.
5
MARKING AND INSTRUCTIONS
Copy of the markings :
Comprehensible and easily
discernible
discernible
On the rear panel
P
Permanent durability against water
and petroleum spirit
and petroleum spirit
Tested with water / spirit
P
5.1
Identification, maker, model
Maker’s name: harman/kardon
Model number: DVD 25
Model number: DVD 25
P
Class II symbol
Present on rear panel
P
Rated supply voltage and symbol
AC-symbol (
~
)
90 – 250V
P
Rated mains frequency
50/60Hz
P
Rated current or power
consumption
consumption
20W
P
5.2
Earth terminal
None
N
Hazardous live terminals
No live parts accessible
P
-
IEC 60065, 6th edition : 1998
-
- Page 6 of 32 -
Order No. 200225249
Supply output terminals (other than
mains)
mains)
No socket outlet for providing power to other apparatus
N
5.3
Use of triangle with exclamation
mark
(Symbol ISO 7000-0434)
Correct symbol applied: Imprinted on rear side in
connection with CAUTION of opening.
connection with CAUTION of opening.
Further: No incorrect use of this symbol found.
P
5.4
Instructions for use
See summary of testing
P
5.4.1
Mains powered equipment not
exposed to dripping or splashing
exposed to dripping or splashing
Adequate instructions supplied
Hazardous live terminals,
instructions for wiring
instructions for wiring
No hazardous live terminals
N
Instructions for replacing lithium
battery
battery
No lithium batteries
N
Explanation of marking of the
manually operated mechanical
switch (MOMS)
manually operated mechanical
switch (MOMS)
No explanation required (indication in the form of
illumination)
illumination)
P
5.4.2
Instructions for permanently
connected equipment
If not completely switched OFF from
the mains, info required
connected equipment
If not completely switched OFF from
the mains, info required
Apparatus not permanently connected
N
6
HAZARDOUS RADIATION
No radiation
N
6.1
High voltage (kV).
—
Focus voltage (kV)
—
Amount of radiation
—
6.2
Non-ionizing radiation (laser
radiation)
radiation)
Measured by JQA Laser lab. : Class 1 Laser Product
Laser radiation measured according to EN 60825-1
JQA reference: 384-10231-1
Laser radiation measured according to EN 60825-1
JQA reference: 384-10231-1
P
6.2.1
Opening of any cover by hand
The front drawer is operated electrically with a push
button.
button.
N
Mechanical interlocking device
Not possible to open front drawer by hand.
N
Accessible emission normal
operation / classification
operation / classification
Within AEL of class 1
P
Labelling
Class 1 Laser Product
P
6.2.2
Accessible emission fault condition
outside / inside
outside / inside
Within AEL of Class 3A
P
Inside label requirement
Complies with requirements
P
-
IEC 60065, 6th edition : 1998
-
- Page 7 of 32 -
Order No. 200225249
7
HEATING UNDER NORMAL
OPERATING CONDITIONS
OPERATING CONDITIONS
P
Power consumption in the
OFF/Stand-by
OFF/Stand-by
Off – 0W
Stand by – 7.1W
Stand by – 7.1W
7.1
U =
81
V,
I =
0.25
A,
P =
13.9
W
U =
90
V,
I =
0.23
A,
P =
13.6
W
U =
250
V,
I =
0.11
A,
P =
13.7
W
U =
265
V,
I =
0.10
A,
P =
14.1
W
Operating conditions:
U =
265
V,
I =
0.10
A,
P =
14.1
W
Loudspeaker system(s)
None
7.1
Temperature rises not exceeding
specified values, no operation of
protective devices
specified values, no operation of
protective devices
P
7.1.1
Temperature rise of accessible parts
(see table below)
√
7.1.2
Temperature rise of parts providing
electrical insulation
electrical insulation
(see table below)
√
7.1.3
Temperature rise of parts acting as
a support or as a mechanical barrier
a support or as a mechanical barrier
(see table below)
√
7.1.4
Temperature rise of windings
(see table below)
√
7.1.5
Parts not subject to a limit under
7.1.1 to 7.1.4
7.1.1 to 7.1.4
(see table below)
√
-
IEC 60065, 6th edition : 1998
-
- Page 8 of 32 -
Order No. 200225249
HEATING
P
Test voltage
90/265V
Other measured parts
∆
t measured
∆
t measured
81V
∆
t measured
265V
∆
t allowed
L1
24.7
13.7
75
L2
27.0
17.2
75
T1-coil
20.3
41.0
75
T1-core
18.6
24.4
75
C1
17.4
18.1
60
IC2
19.8
20.4
Enclosure
6.9
7.3
40
Ambient
25.6
26.6
Comments
No other parts were observed to create any hazard due to temperature rise.
All other temperatures are far below permissible limits
7.2
Softening temperature of insulating
material supporting parts
conductively connected to the mains
carrying a current > 0,2 A at least
150
material supporting parts
conductively connected to the mains
carrying a current > 0,2 A at least
150
°
C
N
Tested parts
Temperature
under normal
operating con-
ditions (°C)
Temperature
under fault
conditions
(°C)
Softening
temperature
(°C)
Click on the first or last page to see other DVD 25 service manuals if exist.