Harman Kardon DVD 25 EMC - CB Certificate ▷ View online
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998 -
- Page 1 of 3 -
Order No. 200225249
APPENDIX
CENELEC EN 60065:1998
CENELEC COMMON MODIFICATIONS, SPECIAL NATIONAL CONDITIONS,
NATIONAL DEVIATIONS AND OTHER INFORMATION
NATIONAL DEVIATIONS AND OTHER INFORMATION
P
C = CENELEC common modification, S = Special National condition, D = National deviation, F = Other information
DE = Germany, DK = Denmark, GB = United kingdom, FI = Finland, IE = Ireland, IT = Italy, NO = Norway, SE =
Sweden.
P = Pass, F = Fail, N = Not applicable.
Sweden.
P = Pass, F = Fail, N = Not applicable.
1.1.1 C
Replace text in Note 1 by : This
standard can be used as a guide
for the testing of battery operated
apparatus.
standard can be used as a guide
for the testing of battery operated
apparatus.
—
2.6.1 S
(DK) Class I apparatus provided
with a plug not establishing earthing
continuity when inserted in Danish
socket-outlets, see 15.1.1.
with a plug not establishing earthing
continuity when inserted in Danish
socket-outlets, see 15.1.1.
N
3.1 C
Delete the note. Add the following
indent : exposure to excessive
sound pressures from headphones
or earphones.
indent : exposure to excessive
sound pressures from headphones
or earphones.
No headphones or earphones outlet
N
5 D
(DE) Marking in case of intrinsically
ionizing radiation, cathode-ray
tubes
ionizing radiation, cathode-ray
tubes
N
5 D
(IT) Marking and instruction
requirements
- power consumption (W) for TV
receivers
requirements
- power consumption (W) for TV
receivers
N
6.1 D
(DE) Limits for ionizing radiation,
TV receivers (max. 1
TV receivers (max. 1
µ
Sv/h)
N
15.1.1 C
Delete notes 1 and 2.
Add to note 4: Attention is drawn to
the fact that a standard is under
preparation (presently prEN 50074)
for socket-outlets which allow
connection of Class II appliances
only.
Add to note 4: Attention is drawn to
the fact that a standard is under
preparation (presently prEN 50074)
for socket-outlets which allow
connection of Class II appliances
only.
N
15.1.1 S
(DK) Mains plug according to
Heavy Current Regulations, Section
107-2-D1
(DK) Mains socket outlets Cl.I
(DK) Mains socket outlets Cl.II
Heavy Current Regulations, Section
107-2-D1
(DK) Mains socket outlets Cl.I
(DK) Mains socket outlets Cl.II
The apparatus must be delivered with an approved
power cord when marketed in Denmark.
power cord when marketed in Denmark.
—
15.1.1 S
(IE) Mains plug, flexible cord,
according to statutory Instrument
525: 1997
according to statutory Instrument
525: 1997
The apparatus must be delivered with an approved
power cord when marketed in Ireland.
power cord when marketed in Ireland.
—
15.1.1 S
(NO) Mains socket outlets CI.II
N
15.1.1 S
(GB) Mains plug, flexible cord,
according to statutory Instrument
1768: 1994
according to statutory Instrument
1768: 1994
The apparatus must be delivered with an approved
power cord when marketed in Great Britain.
power cord when marketed in Great Britain.
—
15.2 C
Delete note 2
N
16.1 C
Delete note 1
N
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998 -
- Page 2 of 3 -
Order No. 200225249
16.2 C
Delete the note
—
20 C
Delete note 2
—
APPENDIX
ANNEX B (normative)
N
Annex B C
Delete note 2
N
B.5.4.1 S
(NO) Marking stating that the
apparatus must be connected to an
earthed mains socket outlet.
Applicable text is:
"Apparatet må kun tilkoples jordet
stikkontakt" or
"Jordet stikkontakt skal benyttes
når apparatet tilkoples datanett"
Swedish text can also be accepted.
apparatus must be connected to an
earthed mains socket outlet.
Applicable text is:
"Apparatet må kun tilkoples jordet
stikkontakt" or
"Jordet stikkontakt skal benyttes
når apparatet tilkoples datanett"
Swedish text can also be accepted.
N
B.5.4.1 S
(SE) Marking stating that the
apparatus must be connected to an
earthed mains socket outlet.
The marking text shall be in
Swedish and as follows:
"Apparaten skall anslutas till jordat
uttag när den ansluts till ett nätverk"
apparatus must be connected to an
earthed mains socket outlet.
The marking text shall be in
Swedish and as follows:
"Apparaten skall anslutas till jordat
uttag när den ansluts till ett nätverk"
N
B.5.4.1 e)
C
C
Delete notes 1 and 2
N
B.8.1 C
Delete notes 1, 2 and 3
N
B.8.1 S
(DK) Method b) is permitted only for
PERMANENTLY CONNECTED
APPARATUS
PERMANENTLY CONNECTED
APPARATUS
N
B.8.1 S
(NO) Method b) is not permitted
N
B.8.2 C
Delete the note
N
B.14.12 C
Delete notes 1 and 2
N
B.14.12 S
(DK) The following note is added:
NOTE in Denmark the use of surge
suppressors between the
TELECOMMUNICATION
NETWORK and conductive
ACCESSIBLE parts or
TERMINALS which are considered
to be ACCESSIBLE, is allowed only
for PERMANENTLY CONNECTED
APPARATUS.
NOTE in Denmark the use of surge
suppressors between the
TELECOMMUNICATION
NETWORK and conductive
ACCESSIBLE parts or
TERMINALS which are considered
to be ACCESSIBLE, is allowed only
for PERMANENTLY CONNECTED
APPARATUS.
N
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998 -
- Page 3 of 3 -
Order No. 200225249
B.14.12 S
(NO) The following note is added:
NOTE in Norway, for Class I
apparatus intended to be
connected to the MAINS by means
of a plug, surge suppressors may
only be connected between TNV
circuits and ACCESSIBLE parts if
the apparatus has a marking stating
that it must be connected to an
earthed MAINS socket outlet.
NOTE in Norway, for Class I
apparatus intended to be
connected to the MAINS by means
of a plug, surge suppressors may
only be connected between TNV
circuits and ACCESSIBLE parts if
the apparatus has a marking stating
that it must be connected to an
earthed MAINS socket outlet.
N
B.14.12 S
(SE) The following note is added:
NOTE in Sweden, for Class I
apparatus intended to be
connected to the MAINS by means
of a plug, surge suppressors may
only be connected between TNV
circuits and ACCESSIBLE parts if
the apparatus has a marking stating
that it must be connected to an
earthed MAINS socket outlet.
The marking text shall be in
Swedish and as follows:
"Apparaten skall anslutas till jordat
uttag."
NOTE in Sweden, for Class I
apparatus intended to be
connected to the MAINS by means
of a plug, surge suppressors may
only be connected between TNV
circuits and ACCESSIBLE parts if
the apparatus has a marking stating
that it must be connected to an
earthed MAINS socket outlet.
The marking text shall be in
Swedish and as follows:
"Apparaten skall anslutas till jordat
uttag."
N
APPENDIX
ANNEX G (normative)
P
Annex G C
Delete the note
N
APPENDIX
ANNEX P (informative)
P
Annex P C
Add the following notes for the
standards indicated :
standards indicated :
IEC 60130 :
NOTE: IEC 60130-9:1989 +
A1:1993 are harmonized as EN
60130-9 (not modified).
IEC 60169 :
NOTE: Parts 23, 24 and 25 are
harmonized as Ens (not modified).
IEC 60173 :
NOTE: Harmonized as HD 27
S1:1983 (not modified).
IEC 60260 :
NOTE: Harmonized as HD 98
S1:1977 (not modified).
IEC 60335-2-56 :
NOTE: Harmonized as EN 60335-
2-56: 1997 (not modified).
IEC 61040 :
NOTE: Harmonized as EN 61040:
1992 (not modified).
IEC 60695 :
NOTE: Harmonized as EN 60695
series (not modified).
NOTE: IEC 60130-9:1989 +
A1:1993 are harmonized as EN
60130-9 (not modified).
IEC 60169 :
NOTE: Parts 23, 24 and 25 are
harmonized as Ens (not modified).
IEC 60173 :
NOTE: Harmonized as HD 27
S1:1983 (not modified).
IEC 60260 :
NOTE: Harmonized as HD 98
S1:1977 (not modified).
IEC 60335-2-56 :
NOTE: Harmonized as EN 60335-
2-56: 1997 (not modified).
IEC 61040 :
NOTE: Harmonized as EN 61040:
1992 (not modified).
IEC 60695 :
NOTE: Harmonized as EN 60695
series (not modified).
P
- APPENDIX EMKO-TSE (92-SEC) 208/94 TO IEC 60065 (TRF 94-10) -
- Page 1 of 1 -
Order No. 200225249