EMC - CB Certificate
Brand
Device
Audio
File
dvd-25.pdf
Date

Harman Kardon DVD 25 EMC - CB Certificate ▷ View online

 
IEC 60065, 6th edition : 1998
 - 
- Page 25 of 32 - 
 
 
   
 
Order No.  200225249 
 
 
 
Components and parts as above but 
shielded from a potential ignition 
source, with the barrier area in 
accordance with Table 13 and 
fig. 13  
 
20.2 
Fire enclosure 
 
20.2.1 
Potential ignition sources with open 
circuit voltage > 4 kV (peak) a.c. or 
d.c. contained in a fire enclosure to 
FV 1  
 
— 
20.2.2 
Internal fire enclosures with 
openings not exceeding 1 mm in 
width and with openings for wires 
completely filled  
 
— 
20.2.3 
Requirements of 20.2.1 and 20.2.2 
met by an internal fire enclosure  
 
— 
 
ANNEX A, ADDITIONAL 
REQUIREMENTS FOR 
APPARATUS WITH PROTECTION 
AGAINST SPLASHING WATER  
 
A.5.1 
j) Marked with IPX4 (IEC 60 529), 
5.4.1 a) does not apply  
 
— 
A.10.2.1 
Enclosure provides protection 
against splashing water  
 
— 
A.10.2.2 
Humidity treatment carried out for 
7 days  
 
— 
 
ANNEX B, APPARATUS TO BE 
CONNECTED TO THE 
TELECOMMUNICATION 
NETWORKS  
 
B.5.4.1 
e) Where the separation of TNV 
circuits from other circuits relies on 
protective earthing the instructions 
make it clear that protective earthing 
is essential  
 
— 
B.8.1 
TNV circuits separated from the mains circuit and from hazardous live parts by either: 
 
— 
 
a) double or reinforced insulation  
 
— 
 
b) basic insulation with earthed 
protective screening  
 
— 
B.8.2 
TNV circuits separated from circuits 
other than those in B.8.1 and from 
accessible conductive parts by basic 
insulation meeting the requirements 
for clearances and creepage 
distances for the voltages concerned  
 
— 
 
IEC 60065, 6th edition : 1998
 - 
- Page 26 of 32 - 
 
 
   
 
Order No.  200225249 
 
 
B.9.1.1 
TNV circuit terminals contacts which 
cannot be touched by probe B.1, 
exempt from the requirements 
inaccessible terminal contacts in 
9.1.1  
 
— 
B.10.1 
Insulation between TNV terminals 
and antenna terminals (including 
interconnection terminals which may 
be connected to equipment with 
antenna terminals) withstands the 
50 discharges of 10.1  
 
— 
B.14.12 
Surge suppressors between TNV 
circuits and other parts of the 
equipment have breakdown voltage 
at least 1,8 times the mains voltage  
 
— 
 
IEC 60065, 6th edition : 1998
 - 
- Page 27 of 32 - 
 
 
   
 
Order No.  200225249 
 
 
 
 
LIST OF CRITICAL COMPONENTS 
 
√ 
Part No 
Component/ 
Object 
Manufacturer 
Type / Model 
Ratings / 
Technical 
Data 
Complies 
with the 
following 
standard 
Marks of 
conformity 
granted ** 
 
Mains 
transformer 
Fuzhou Xiangban Co. 
BCK-ER2803  Class E 
IEC60065 
1) 
 
Filter Coil 
Fuzhou Xiangban Co. 
LCLET20-
010 
Class B 
IEC60065 
1) 
 
Mains plug 
with Cord 
 
LEONI 
H03VVH2-F 
6A/300V 
2x0.75mm² 
IEC60884 
N, FI, VDE 
 
Mains fuse 
Littlefuse 
50T 
1A/250V 
IEC60127-1 
VDE 
 
Mains switch 
Zhang Jia Gang 
PS4 
5/80A 250V 
IEC61058-1 
VDE 
 
X-capacitor 
Xiamen Fara Developm. 
Nanjing General Electric 
MKT 61 
 
CT7 
0.1uF 275V 
 
1nF/4.7nF 
400V 
IEC60384-
14 

 
VDE 
 
Y- capacitor 
Nanjing General Electric 
CT7 
1nF/4.7nF 
400V 
IEC60384-
14 
VDE 
 
Optocoupler 
Sharp 
PC817 
 
IEC60950 
FI 
 
Smoothing 
capacitor 
Various 
Various 
68uF 450V 
 
 
 
Comments 
 
 
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications  respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998 
 
IEC 60065, 6th edition : 1998
 - 
- Page 28 of 32 - 
 
 
   
 
Order No.  200225249 
 
 
 
 
FAULT CONDITION TESTS  
√ 
Ambient temperature  
 25°C 
Rated voltage  
90 – 250V 
Remarks  
 
Comp. 
No 
Fault 
Test V 
Short 
current 
Test 
time 
Fuse No 
Current 
through 
fuse 
Mains power/temperatures/results 
D4 
S-c 
265V 
 
10 min 
F1 
0.02A 
Power shut down. Max temp on 
transformer coil is 115°C. L4 def. 
No hazard.  
D5 
S-c 
265V 
 
<1 sec 
F1 
0.11A 
Power shut down immediately. No 
temperature rises. No hazard. 
D6 
S-c 
265V 
 
<1 sec 
F1 
0.09A 
Power shut down immediately. No 
temperature rises. No hazard. 
D7 
S-c 
265V 
 
5 sec 
F1 
0.09A 
Power shut down. R102 def. No 
hazard. 
D8 
S-c 
265V 
 
10 min 
F1 
0.02A 
Display is not working.  Max temp 
on transformer coil is 95°C. L4 def. 
No hazard. 
D3 
S-c 
265V 
 
10 min 
F1 
0.02A 
Power shut down. Max temp on 
transformer coil is 102°C. L4 def. 
No hazard.  
C4 
S-c 
265V 
 
<1 sec 
F1 
0.1A 
Power cycles. No temperature 
rises. No hazard. 
C10 
S-c 
265V 
 
<1 sec 
F1 
0.12A 
Power cycles. No temperature 
rises. No hazard. 
C11 
S-c 
265V 
 
<1 sec 
F1 
0.12A 
Power cycles. No temperature 
rises. No hazard. 
C39 
S-c 
265V 
 
<1 sec 
F1 
0.02A 
Display is not working. D8 
defective. L4 def. No high 
temperature rises.  No hazard. 
IC3 
A-K
 
S-c 
265 
 
<1 sec 
F1 
0.02A 
Power goes into standby. No 
temperature rises. No hazard. 
R14 
O-c 
265 
 
8 min  
F1  
0.01A 
Output overvoltage. No hazardous 
voltages out of apparatus. Lot of 
components broken on secondary 
side. No high temperature rises. L4 
broken on primary side. No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 
Page of 43