Page 49 of 100 
 
ST-07348  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
7.2 
After the second paragraph, add the following: 
The alternative method described in footnote h) of 
Table 3 may be used. 
 
N/A 
15.1.1 
After the second paragraph, add the following: 
Plugs for the connection of apparatus to mains-
powered socket-outlets shall comply with AS/NZS 
3112 or AS/NZS 3123. Apparatus with a plug 
portion, suitable for insertion into a 10 A 3-pin flat-
pin socket-outlet complying with AS/NZS 3112, 
shall comply with the requirements of AS/NZS 
3112 for equipment with integral pins for insertion 
into socket-outlets. 
See the Note in appended 
table 14 
N/A 
15.3.5 
In Table 15, in the second and third rows of the 
first column replace ‘6’ with ‘7.5’. 
 
N/A 
16.2 
In Table 18, in the second and third rows of the 
first column replace ‘6’ with ‘7.5’. 
See the Note in appended 
table 14 
N/A 
16.3 
In item (b), add the following: 
A flexible cord complying with AS/NZS 3191 need 
not undergo this test. 
 
N/A 
20 
Add the following after NOTE 2: 
For alternative test refer to Clause 20.201. 
 
N/A 
20.1.4 
In Table 21, in the third and fourth columns 
change both ‘HB75’ and ‘No requirement’ to ‘V-1’. 
 
20.2.3 
After this Clause, add the following variation: 
20.201 Resistance to fire – Alternative tests 
 
N/A 
 
 
 
 
Page 50 of 100 
 
ST-07348  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
20.201.1 
General 
Parts of non-metallic material shall be resistant to 
ignition and the spread of fire. 
This requirement does not apply to decorative 
trims, knobs and other parts unlikely to be ignited 
or to propagate flames originating from inside the 
apparatus, or the following: 
a) Components that are contained in an 
enclosure having a flammability category of V-0 
according to AS/NZS 60695.11.10 and having 
openings only for the connecting wires filling the 
openings completely, and for ventilation not 
exceeding 1 mm in width regardless of length. 
b) The following parts which would contribute 
negligible fuel to a fire: 
- small mechanical parts, the mass of which does 
not exceed 4 g, such as mounting parts, gears, 
cams, belts and bearings; 
- small electrical components, such as capacitors 
with a volume not exceeding 1 750 mm
3
integrated circuits, transistors and optocoupler 
packages, if these components are mounted on 
material of flammability category V-1 or better 
according to AS/NZS 60695.11.10. 
NOTE – In considering how to minimize 
propagation of fire and what ‘small parts’ are, 
account should be taken of the cumulative effect 
of small parts adjacent to each other for the 
possible effect of propagating fire from one part to 
another. 
Compliance shall be checked by the tests of 
20.201.2.1, 20.201.2.2. and 20.201.2.3. 
For the base material of printed boards, 
compliance shall be checked by the test of 
20.201.2.4. 
The tests shall be carried out on parts of non-
metallic material which have been removed from 
the apparatus. 
When the glow-wire test is carried out, they are 
placed in the same orientation as they would be 
in normal use. 
These tests are not carried out on internal wiring. 
 
N/A 
20.201.2 
Tests 
 
 
 
 
 
Page 51 of 100 
 
ST-07348  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
20.201.2.1  Testing of non-metallic parts 
Part of non-metallic material shall be subject to 
the glow-wire test of AS/NZS 60695.2.11 which 
shall be carried out at 550 °C. 
Parts for which the glow-wire test cannot be 
carried out, such as those made of soft or foamy 
material, shall meet the requirements specified in 
ISO 9772 for category FH-3 material. The glow-
wire test shall not be carried out on parts of 
material classified at least FH-3 according to ISO 
9772 provided that the sample tested was not 
thicker than the relevant part. 
 
N/A 
20.201.2.2  Testing of insulated parts 
Part of insulating material supporting potential 
ignition sources shall be subject to the glow-wire 
test of AS/NZS 64695.2.11 which shall be carried 
out at 750 °C. 
The test shall be also carried out on other parts of 
insulating material which are within a distance of 
3 mm of the connection. 
NOTE – Contacts in components such as switch 
contacts are considered to be connections. 
For parts which withstand the glow-wire test but 
produce a flame, other parts above the 
connection within the envelope of a vertical 
cylinder having a diameter of 20 mm and a height 
of 50 mm shall be subjected to the needle-flame 
test. However, parts shielded by a barrier which 
meets the needle-flame test need not be tested. 
The needle-flame test shall be made in 
accordance with AS/NZS 4695.2.2 with the 
following modifications: 
Clause of AS/NZS 
4695.2.2
 
Change 
5 Severities 
Replace with: 
The duration of application 
of the test flame shall be 30 
±
 1 s. 
 
 
N/A 
 
 
 
 
Page 52 of 100 
 
ST-07348  
 
IEC/EN 60065 
Clause 
Requirement – Test 
Result - Remark 
Verdict 
 
TRF No.: IECEN60065G 
 
 
 
(cont.) 
8 Test procedure 
 
8.2 
 
 
 
 
Replace the first sentence 
with: 
The specimen shall be 
arranged so that the flame 
can be applied to a vertical 
or horizontal edge as shown 
in the examples of figure 1. 
8.4 
 
 
 
The first paragraph does not 
apply. 
Addition: 
If possible, the flame shall 
be applied at least 10 mm 
from a corner. 
8.5 
Replace with:  
The test shall be made on 
one specimen. If the 
specimen does not 
withstand the test, the test 
may be repeated on two 
further specimens, both of 
which shall then withstand 
the test. 
10 Evaluation of 
test results 
Replace with: 
The duration of burning (tb) 
shall not exceed 30 s. 
However, for printed circuit 
boards, it shall not exceed 
15 s. 
The needle-flame test shall not be carried out on 
parts of material classified as V-0 or V-1 
according to AS/NZS 60695.11.10 provided that 
the sample tested was not thicker than the 
relevant part. 
 
N/A 