Harman Kardon DMC 1000 (serv.man2) EMC - CB Certificate ▷ View online
Page 53 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
20.201.2.3 Testing by needle-flame test
If parts, other than enclosures, do not withstand
the glow wire tests of 20.201.2.2, by failure to
extinguish within 30 s after the removal of the
glow-wire tip, the needle-flame test detailed in
20.201.2.2 shall be made on all parts of non-
metallic material which are within a distance of 50
mm or which are likely to be impinged upon by
flame during the tests of 20.201.2.2. Parts
shielded by a separate barrier which meets the
needle-flame test shall not be tested.
the glow wire tests of 20.201.2.2, by failure to
extinguish within 30 s after the removal of the
glow-wire tip, the needle-flame test detailed in
20.201.2.2 shall be made on all parts of non-
metallic material which are within a distance of 50
mm or which are likely to be impinged upon by
flame during the tests of 20.201.2.2. Parts
shielded by a separate barrier which meets the
needle-flame test shall not be tested.
NOTE 1 – If the enclosure does not withstand the
glow-wire test the appliance is considered to have
failed to meet the requirements of Clause 21.201
without the need for consequential testing.
glow-wire test the appliance is considered to have
failed to meet the requirements of Clause 21.201
without the need for consequential testing.
NOTE 2 – If other parts do not withstand the
glow-wire test due to ignition of the tissue paper
and if this indicates that burning or glowing
particles can fall onto an external surface
underneath the apparatus, the apparatus is
considered to have failed to meet the
requirements of Clause 21.201 without the need
for consequential testing.
glow-wire test due to ignition of the tissue paper
and if this indicates that burning or glowing
particles can fall onto an external surface
underneath the apparatus, the apparatus is
considered to have failed to meet the
requirements of Clause 21.201 without the need
for consequential testing.
NOTE 3 – Parts likely to be impinged upon by the
flame are considered to be those within the
envelope of a vertical cylinder having a radius of
10 mm and a height equal to the height of the
flame, positioned above the point of the material
supporting, in contact with, or in close proximity
to, connections.
flame are considered to be those within the
envelope of a vertical cylinder having a radius of
10 mm and a height equal to the height of the
flame, positioned above the point of the material
supporting, in contact with, or in close proximity
to, connections.
N/A
Page 54 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
20.201.2.4 Testing of printed boards
The base material of printed boards shall be
subject to the needle-flame test of Clause
21.201.2.3. The flame shall be applied to the
edge of the board where the heatsink effect is
lowest when the board is positioned as
subject to the needle-flame test of Clause
21.201.2.3. The flame shall be applied to the
edge of the board where the heatsink effect is
lowest when the board is positioned as
in normal use. The flame shall not be applied to
an edge consisting of broken perforations, unless
the edge is less than 3 mm from a potential
ignition source.
an edge consisting of broken perforations, unless
the edge is less than 3 mm from a potential
ignition source.
The test is not carried out if the—
- printed board does not carry any potential
ignition source;
ignition source;
- base material of printed boards, on which the
available power at a connection exceeds 15 VA
operating at a voltage exceeding 50 V and equal
or less than 400 V (peak) a.c. or d.c. under
normal operating conditions, is of flammability
category V-1 or better according to AS/NZS
60695.11.10, or the printed boards are protected
by an enclosure meeting the flammability
category V-0 according to AS/NZS 60695.11.10,
or made of metal, having openings only for
connecting wires which fill the openings
completely; or
available power at a connection exceeds 15 VA
operating at a voltage exceeding 50 V and equal
or less than 400 V (peak) a.c. or d.c. under
normal operating conditions, is of flammability
category V-1 or better according to AS/NZS
60695.11.10, or the printed boards are protected
by an enclosure meeting the flammability
category V-0 according to AS/NZS 60695.11.10,
or made of metal, having openings only for
connecting wires which fill the openings
completely; or
- base material of printed boards, on which the
available power at a connection exceeds 15 VA
operating at a voltage exceeding 400 V (peak)
a.c. or d.c. under normal operating conditions,
and base material of printed boards supporting
spark gaps which provides protection against
overvoltages, is of flammability category V-0
according to AS/NZS 60695.11.10 or the printed
boards are contained in a metal enclosure,
having openings only for connecting wires which
fill the openings completely.
available power at a connection exceeds 15 VA
operating at a voltage exceeding 400 V (peak)
a.c. or d.c. under normal operating conditions,
and base material of printed boards supporting
spark gaps which provides protection against
overvoltages, is of flammability category V-0
according to AS/NZS 60695.11.10 or the printed
boards are contained in a metal enclosure,
having openings only for connecting wires which
fill the openings completely.
Compliance shall be determined using the
smallest thickness of the material.
smallest thickness of the material.
NOTE – Available power is the maximum power
which can be drawn from the supplying circuit
through a resistive load whose value is chosen to
maximize the power for more than 2 min when
the circuit supplied is disconnected.
which can be drawn from the supplying circuit
through a resistive load whose value is chosen to
maximize the power for more than 2 min when
the circuit supplied is disconnected.
N/A
Page 55 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
21.201.3
For open circuit voltages greater than 4 kV
potential ignition sources with open circuit
voltages exceeding 4 kV (peak) a.c. or d.c. under
normal operating conditions shall be contained in
a fire enclosure which shall comply with
flammability category V-1 or better according to
AS/NZS 60695.11.10.
voltages exceeding 4 kV (peak) a.c. or d.c. under
normal operating conditions shall be contained in
a fire enclosure which shall comply with
flammability category V-1 or better according to
AS/NZS 60695.11.10.
N/A
Annex B
After the heading add:
For Australia only, this Annex is replaced by the
requirements of the Telecommunications
Labelling Notice issued under the
Telecommunications Act.
requirements of the Telecommunications
Labelling Notice issued under the
Telecommunications Act.
NOTE – The Telecommunications Act is
administered by the Australian Communications
Authority.
administered by the Australian Communications
Authority.
No connected to the
telecommunication networks
telecommunication networks
N/A
Page 56 of 100
ST-07348
IEC/EN 60065
Clause
Requirement – Test
Result - Remark
Verdict
TRF No.: IECEN60065G
National Differences Canada (CA)
IEC 60065, 7th ed. + A1
3
General requirements
3.2A
[Add the following clause]
A component power supply complying with
CAN/CSA-C22.2 No. 60950 is considered to
comply with this construction and fault conditions
of this Standard after taking into account any
relevant conditions of acceptability.
CAN/CSA-C22.2 No. 60950 is considered to
comply with this construction and fault conditions
of this Standard after taking into account any
relevant conditions of acceptability.
N/A
4.2
Normal operating conditions
4.2.1
[Add the following after the fifth paragraph]
For apparatus intended for use at nominal 120 V
ac, the apparatus shall comply with this Standard
at supply voltages between 108 and 125 V. For
apparatus intended for use at nominal 240 V ac,
the apparatus shall comply with this Standard at
supply voltages between 216 and 250 V.
ac, the apparatus shall comply with this Standard
at supply voltages between 108 and 125 V. For
apparatus intended for use at nominal 240 V ac,
the apparatus shall comply with this Standard at
supply voltages between 216 and 250 V.
P
4.2.10
[Add the following after the second paragraph]
As an alternative, a supply apparatus for general
use complying with CAN/CSA-C22.2 No. 223 or
CAN/CSA-C22.2 No. 60950 shall be acceptable.
use complying with CAN/CSA-C22.2 No. 223 or
CAN/CSA-C22.2 No. 60950 shall be acceptable.
N/A
5
Marking and instructions
[Add the following paragraph]
Adhesive nameplates on commercial products
shall comply with CSA C22.2 No. 0.15.
shall comply with CSA C22.2 No. 0.15.
N/A
5.1
Identification and supply ratings
[Add the following item]
hA) date of manufacture: a date or code
identifying the period of manufacture shall be
marked on the apparatus;
identifying the period of manufacture shall be
marked on the apparatus;
Serial Number is provided
P