Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
US United States of America
US
5.1
Add: Component power supplies and adapters
complying with the construction and test
requirements of UL 1310, UL 1950, or UL 60950
fulfill the requirements of items ―a‖ through ―i‖ of
this clause.
complying with the construction and test
requirements of UL 1310, UL 1950, or UL 60950
fulfill the requirements of items ―a‖ through ―i‖ of
this clause.
N/A
5.1f
Add: Rated frequency is required on all apparatus
P
5.1g
Add: Rated current or power required on all
apparatus.
apparatus.
P
5.1j
Add: Date of Manufacture‖ marking required on
all apparatus.
all apparatus.
Manufactured: May 2012
P
5.1k
Add: Manufacturing identification marking
required.
required.
N/A
5.1l
Add: Combination of two graphical symbols and
supplementary marking is required.
supplementary marking is required.
P
5.1m
Add: Equipment rack marking required for
audio/video systems.
audio/video systems.
N/A
5.1n
Add: Units having leakage current levels greater
than 0.75 MIU and equal to or less than 3.5 MIU
must be marked with a high leakage current
marking.
than 0.75 MIU and equal to or less than 3.5 MIU
must be marked with a high leakage current
marking.
N/A
5.2c
Modification: Output terminals must be marked
with voltage, frequency and current or power;
output terminals installed or interconnected in the
field must be marked with the class of wiring.
with voltage, frequency and current or power;
output terminals installed or interconnected in the
field must be marked with the class of wiring.
N/A
5.2d
Add: Audio output connections shall be marked
―Class 1 Wiring‖, ―Class 2 Wiring‖ or ―Class 3
Wiring‖.
―Class 1 Wiring‖, ―Class 2 Wiring‖ or ―Class 3
Wiring‖.
Operation manual shall discuss risks and proper
connecting and insulating techniques when
connecting a speaker.
connecting and insulating techniques when
connecting a speaker.
N/A
5.3
Add: "An explanation and illustration of safety
related graphical symbols used on the apparatus
shall be included in t
related graphical symbols used on the apparatus
shall be included in t
he owner‘s instructions
preceding any operating instructions.
P
5.4
Add: Important Safety Instructions are to be
packed with each apparatus and shall be
verbatim.
packed with each apparatus and shall be
verbatim.
P
5.4.1
Add: Warning about Outdoor Use is required.
N/A
5.4.3
Add: When apparatus contains instructions for
use by service personnel the instructions are
separate in format and preceded by a
precautionary warning statement.
use by service personnel the instructions are
separate in format and preceded by a
precautionary warning statement.
N/A
Page 58 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
US United States of America
US
6.1
Starting from second paragraph replace all by:
"Compliance is checked in accordance with the
requirements in the U.S. Code of Federal
Regulations, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3, and 1020.10 by
measuring the radiation produced by the
apparatus employing a design center chassis."
"Compliance is checked in accordance with the
requirements in the U.S. Code of Federal
Regulations, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3, and 1020.10 by
measuring the radiation produced by the
apparatus employing a design center chassis."
N/A
6.2
Starting from second paragraph replace all by:
"Apparatus shall be classified and labeled in
accordance with the Code of Federal
Regulations, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3, 1040.10 and 1040.11."
"Apparatus shall be classified and labeled in
accordance with the Code of Federal
Regulations, Title 21, Chapter 1, Subchapter J,
Sections 1010.2, 1010.3, 1040.10 and 1040.11."
P
6.2.2
Deleted
N/A
Table 3
Temperature limits added for various classes of
insulation systems.
insulation systems.
Add to Note a): "Materials rated in accordance
with UL 746B may be used at their rated higher
temperature.".
with UL 746B may be used at their rated higher
temperature.".
P
7.2
Add: A material temperature rating can be
accepted in lieu of the softening temperature. The
softening test need not be performed on
materials used in UL Listed or Recognized parts.
accepted in lieu of the softening temperature. The
softening test need not be performed on
materials used in UL Listed or Recognized parts.
N/A
8.1
Add: ―A metal part that is not inherently resistant
to corrosion shall be protected against corrosion
when corrosion of that part is capable of
contributing to or resulting in a risk of fire, shock,
or injury to persons.‖
to corrosion shall be protected against corrosion
when corrosion of that part is capable of
contributing to or resulting in a risk of fire, shock,
or injury to persons.‖
N/A
8.9.1
Add: ―Sleeving, tape, tubing, and wire insulation
are suitable for the conditions of use, such as
voltageand temperature, and comply with UL 224,
UL 510, and UL 1441, as applicable.‖
are suitable for the conditions of use, such as
voltageand temperature, and comply with UL 224,
UL 510, and UL 1441, as applicable.‖
P
8.10
Add: ―Component power supplies and their
internal insulation complying with the construction
and test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.‖
internal insulation complying with the construction
and test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.‖
N/A
8.12
Modification: Conductors and internal wiring
connecting mains socket-outlets shall comply with
the wire size requirements in clause 16.2 based
on the marked rating of the outlet but shall not be
less than 18 AWG.
connecting mains socket-outlets shall comply with
the wire size requirements in clause 16.2 based
on the marked rating of the outlet but shall not be
less than 18 AWG.
P
8.17
Add: As an option, winding wire insulation may
comply with the requirements in UL Subject 2353.
comply with the requirements in UL Subject 2353.
N/A
8.19.1
Modification: An all-pole switch or circuit breaker
is not required to have contact separation of 3
mm.
is not required to have contact separation of 3
mm.
N/A
Page 59 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
US United States of America
US
8.22
Add: ―Printed wiring boards involved with the risk
of electric shock shall comply with the
requir
of electric shock shall comply with the
requir
ements in UL 796.‖
P
9.1.1.1
Replace: For Class I apparatus the r.m.s.
TOUCH-CURRENT to earth shall not be more
than 3.5 MIU.
TOUCH-CURRENT to earth shall not be more
than 3.5 MIU.
N/A
9.1.1.1a
2nd dash replaced by: ―For audio signals of
professional and commercial apparatus, 120 V
r.m.s.‖
professional and commercial apparatus, 120 V
r.m.s.‖
3rd dash replace
d by: ―For audio signals other
than professional and commercial apparatus, 71
V r.m.s.‖
V r.m.s.‖
P
9.1.1.1b
Modification: Touch current shall comply with the
American National Standard for Leakage Current
for Appliances, ANSI C101 and not exceed 0.5
MIU for Class ll Delete Note 2.
American National Standard for Leakage Current
for Appliances, ANSI C101 and not exceed 0.5
MIU for Class ll Delete Note 2.
P
9.1.1.2
UL articulated finger replaces IEC 61032 test
probe B. Delete 3rd paragraph.
probe B. Delete 3rd paragraph.
Table 5 -
Add Note 1: ―With respect to mains
voltages in the range of 105-130 V (r.m.s.), the
test voltages are considered to be 1414 V peak
for basic and supplementary insulation and 2828
V peak for reinforced insulation.‖
test voltages are considered to be 1414 V peak
for basic and supplementary insulation and 2828
V peak for reinforced insulation.‖
P
11
Add: ―Component power supplies and their power
transformers complying with the construction and
test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.‖
transformers complying with the construction and
test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.‖
N/A
11.1
Modification: The permissible touch current for
terminal contacts has been increased to twice the
value given in 9.1.1.1.
terminal contacts has been increased to twice the
value given in 9.1.1.1.
P
11.2.1
Modification: Additional fuse testing not required if
the temperature is limited by fuses.
the temperature is limited by fuses.
N/A
12
Add: ―Component power supply adaptors and
their enclosures complying with the construction
and test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the c
their enclosures complying with the construction
and test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the c
lause.‖
N/A
12.1.3
Delete the first two paragraphs. Impact test uses
the 50mm steel sphere only.
the 50mm steel sphere only.
Table 6
– Replace title with ―Apparatus impact
test.‖ Table 6 modified to provide impact test
criteria detailing impact location, impact energy
and additiona
criteria detailing impact location, impact energy
and additiona
l pass/fail results.‖
P
12.1.4
Add to the end of the 1st paragraph: ―As an
alternative, any number form one to three
samples are permitted to be used in any
combination that results in a total of three drops.‖
alternative, any number form one to three
samples are permitted to be used in any
combination that results in a total of three drops.‖
N/A
Page 60 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
US United States of America
US
12.1.6
Add: Handle strength test requirements.
N/A
12.7
Add: Wall and ceiling mounting means test
requirements.
requirements.
N/A
12.8
Add test for enclosures, barriers, components
and leads that rely on adhesive.
and leads that rely on adhesive.
N/A
12.8.1
Add test for conductive labels secured in place by
adhesive.
adhesive.
N/A
13
Add: ‖Component power supplies and their power
transformers complying with the construction and
test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.‖
transformers complying with the construction and
test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements on the clause.‖
N/A
13.4
Modification: A material group is verified
according to UL 746A.
according to UL 746A.
P
13.5.1
Change standard reference from IEC 60249-2 to
UL 796.
UL 796.
N/A
13.5.2
Modification: Coated printed wiring boards shall
comply with requirements in UL 746C
comply with requirements in UL 746C
Table 12 - Note 3 revised to refer to UL 746A.
N/A
14
Delete Note 2. Add reference to Annex Y and
additional component requirements.
additional component requirements.
P
14.1,
14.2,
14.3
14.2,
14.3
Add: Component power supplies and their
resistors complying with the construction
resistors complying with the construction
and test requirements of UL 1310, UL 1950 Third
Edition, or UL 60950 are considered to fulfill the
test requirements of Clause 14.1 and 14.2.1
Edition, or UL 60950 are considered to fulfill the
test requirements of Clause 14.1 and 14.2.1
–
14.5.2.
P
14.2.1,
14.2.2
14.2.2
Add: ―As an alternative a component such as a
capacitor, a combination capacitor and resistor, a
varistor, or a suppressor shall comply with the
requirements for Across-the Line, Antenna-
Coupling, or Double Protection in UL 1414.‖
capacitor, a combination capacitor and resistor, a
varistor, or a suppressor shall comply with the
requirements for Across-the Line, Antenna-
Coupling, or Double Protection in UL 1414.‖
P
14.2.4
Replace text with: ―Components subjected to the
requirements in 14.2.1 and 14.2.2 shall also
comply with the enclosure requirements of UL
1414.‖
requirements in 14.2.1 and 14.2.2 shall also
comply with the enclosure requirements of UL
1414.‖
N/A
14.4
Add to Note 2:
―High voltage materials shall be
rated 94V-
2 minimum.‖
Modification: Compliance is checked by meeting
requirements for category V-2 according to UL
94. Moreover the requirements are added for
arcing, component part flame and high-voltage
isolating component tests.
requirements for category V-2 according to UL
94. Moreover the requirements are added for
arcing, component part flame and high-voltage
isolating component tests.
N/A
14.4.1
Replace with High voltage arcing test.
N/A
14.4.2
Deleted
N/A
14.4.3
Add: High voltage component part flame test.
N/A