Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
NO  Norway 
NO 
 
- the Impulse test of 2.5kV is to be performed 
before the Endurance Test in IEC 60384-14 in the 
sequence of tests as described in IEC 60384-14. 
Subclause 5.3.2 (Corrigendum 1): 
Add after the fourth dash: 
NOTE - In Norway, exclusions are applicable for 
equipment which is intended for connection to the 
building installation wiring using screw terminals 
or other reliable means, and for equipment which 
is intended for connection to the building 
installation wiring via an industrial plug and socket 
-outlet or an appliance coupler, or both, 
complying with IEC 60309 or with a comparable 
national standard. 
 
 
N/A 
Page 54 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
 
SE  Sweden 
 
Annex B       
Replace NOTE 1 by 
In the CENELEC countries listed in IEC 62151, 
special national conditions apply. 
Add the following: 
All subclauses given below are subclauses of IEC 
62151:2000 (ref. Corrigendum 1 and 2 to IEC 
62151). 
Subclause 4.1.1 (Corrigendum 2):  
Add after the first paragraph: 
NOTE - In Sweden, CLASS I equipment which is 
intended for connection to the building installation 
via a non-industrial plug or a non-industrial 
appliance coupler, or both and in addition is 
intended for connection to other equipment or a 
network shall, if safety relies on connection to 
protective earth or if surge suppressors are 
connected between the network terminals and 
ACCESSIBLE parts, have a marking stating that 
the equipment must be connected to an earthed 
mains socket -outlet. 
The marking text shall be as follows: 
"Apparaten skall anslutas till 
jordat uttag‖ 
Subclause 5.3.1 (Corrigendum 1): 
Add after the first test specifications paragraph: 
NOTE 1 In Finland, Norway and Sweden, there 
are additional requirements for the insulation. 
Renumber the existing note as note 2. 
For additional requirements for the insulation in 
Sweden in the NOTE 1 the following text is added 
between the first and second paragraph (this text 
is identical to the text in EN 60950-1:2001): 
If this insulation is solid, including insulation 
forming part of a component, it shall at least 
consist of either 
- two layers of thin sheet material, each of which 
shall pass the electric strength test below, or 
- one layer having a distance through insulation of 
at least 0,4 mm, which shall pass the electric 
strength test below. 
If this insulation forms part of a semiconductor 
component (e.g. an optocoupler), there is no 
distance through insulation requirement for the 
insulation consisting of an insulating compound 
completely filling the casing, so that 
CLEARANCES and CREEPAGE DISTANCES do 
not exist, if the component passes the electric 
strength test in the accordance with the 
compliance clause below and in addition: 
- passes the test and inspection criteria of 13.6 
with an electric strength test of 10.3 using the test 
voltage of 1,5 kV multiplied by 1,6, and 
- is subject to routine testing for electric strength 
during manufacturing, using a test voltage of 1,5 
kV (for performance of the test see N.2.1). 
 
N/A 
Page 55 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
SE  Sweden 
 
It is permitted to bridge this insulation with a 
capacitor complying with IEC 60384-14:1993, 
subclass Y2. 
A capacitor classified Y3 according to IEC 60384-
14:1993, may bridge this insulation under the 
following conditions: 
- the insulation requirements are satisfied by 
having a capacitor classified Y3 as defined by 
IEC 60384-14, which in addition to the Y3 testing, 
is tested with an Impulse test of 2.5kV defined in 
IEC 62151, subclause 6.2.1; 
- the additional testing shall be performed on all 
the test specimens as described in IEC 60384-
14; 
-  the Impulse test of 2.5kV is to be performed 
before the Endurance Test in IEC 60384-14 in the 
sequence of tests as described in IEC 60384-14. 
Subclause 5.3.2 (Corrigendum 1): 
Add after the fourth dash: 
NOTE - In Sweden, exclusions are applicable for 
equipment which is intended for connection to the 
building installation wiring using screw terminals 
or other reliable means, and for equipment which 
is intended for connection to the building 
installation wiring via an industrial plug and socket 
-outlet or an appliance coupler, or both, 
complying with IEC 60309 or with a comparable 
national standard. 
 
5.3 
To the end of the subclause the following is 
added: 
 
CLASS I apparatus which is intended for 
connection to the building installation wiring via a 
plug or an appliance coupler, or both and in 
addition is intended for connection to other 
apparatus or a network shall, if safety relies on 
connection to protective earth or if surge 
suppressors are connected between the network 
TERMINALS and ACCESSIBLE parts, have a 
marking stating that the apparatus must be 
connected to an earthed MAINS socket-outlet. 
 
The marking text in the applicable countries shall 
be as follows: 
 
In Finland: "Laite on liitettävä suojakoskettimilla 
varustettuun pistorasiaan" 
In Norway: ―Apparatet må tilkoples jordet 
stikkontakt‖ 
In Sweden: ―Apparaten skall anslutas till jordat 
uttag‖ 
 
 
N/A 
5.4.1 
Norway and Sweden 
Secretary Note: Modification at the end of 5.4.1 
 
N/A 
Page 56 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
SE  Sweden 
 
(after the compliance statement) 
already part of A11 (This note will be deleted from 
the final text) 
 
 
 
US  United States of America 
US 
1.1.1 
Scope clarification: 
The standard also covers commercial and 
professional apparatus; professional apparatus 
may also be investigated using UL 1419. 
Projection apparatus is not covered. Household 
games, household gaming and scoring machines, 
satellite receiver antenna positioners are covered 
by this standard but commercial games and 
commercial gaming and scoring machines, and 
other types of antenna positioners are covered by 
other standard. 
Add: Mains connected apparatus intended for 
field installation requires compliance with the 
National Electrical Code, ANSI, NFPA 70. 
 
1.1.3 
Protection against splashing water replaced with 
apparatus intended for outdoor use (See Annex 
A). 
 
N/A 
1.1.5 
Add: Some equipment covered by these 
requirements may also be required to comply with 
applicable requirements in other standards 
 
N/A 
1.2 
Add references to ANSI, ASTM and UL standards   
4.2.1 
Add Note: In the U.S. the RATED SUPPLY 
VOLTAGE for single-phase apparatus is 
assumed to be 120 V or 120/240 V. 
 
4.2.4 
Revision to sub-clause a): Minimum audio output 
is not less than 0.5 W per channel unless the 
maximum audio output is less than 0.5 W per 
channel. 
 
N/A 
4.2.4.1 
Add: ―An apparatus with multiple modes of 
operation, multiple signal input sources, or both, 
is to be operated using each mode of operation or 
signal input source separately, or in combination, 
according to the manufacturer‘s instructions to 
produce the maximum power input‖. 
Table 2: External supply sources are assumed to 
be capable of delivering 30 A, unless otherwise 
specified (no-load voltage and internal resistance 
values in the Table are modified). 
 
4.3.4 
Add: PTC thermistors may also comply with UL 
1434. 
 
N/A 
Page of 127