DOWNLOAD Harman Kardon BDS 575 Service Manual ↓ Size: 3.81 MB | Pages: 127 in PDF or view online for FREE

Model
BDS 575
Pages
127
Size
3.81 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
bds-575.pdf
Date

Harman Kardon BDS 575 EMC - CB Certificate ▷ View online

Page 41 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
JP  Japan (H23) 
JP 
15.1.1 
Replacement: 
Replace  the  paragraph  after  NOTE  2  by  the 
following. 
MAINS 
socket-outlets 
and 
interconnection 
couplers  mounted  on  CLASS  0I  and  CLASS  II 
apparatus shall not permit connection of CLASS I 
apparatus. 
 
N/A
 
15.1.1 
Replacement: 
Replace  the  paragraph  before  NOTE  3  by  the 
following. 
MAINS 
socket-outlets 
and 
interconnection 
couplers mounted on CLASS I apparatus shall be 
provided  with  protective  earthing  contacts  which 
are  reliably  connected  to  the  PROTECTIVE 
EARTHING  TERMINAL  or  contact  of  the 
apparatus. If not, it shall not permit connection of 
CLASS I apparatus. 
 
N/A
 
Replacement: 
Replace NOTE 4 by the following. 
NOTE  4    Socket-outlets  not  allowing  the 
connection  of  CLASS  I  apparatus  can  be 
designed,  for  instance,  similar  to  IEC  60906-1, 
standard  sheets  3-1  or  3-2,  or  according  to  IEC 
60320-2-2, standard sheets D or H. 
 
N/A
 
15.1.2 
Deletion: 
Delete the following sentence in NOTE.  
An  example  of  a  connector  not  meeting  the 
requirements  of  this  sub  clause  is  the  so-called 
"banana" plug. 
 
N/A
 
15.1.3 
Replacement: 
Replace the references, ―IEC 60083 [1], IEC 
60320, IEC 60884, IEC 60906‖ by ―JIS C 8282 
(corresponding to IEC 60884), JIS C 8303, IEC 
60320 and IEC 60906‖. 
Should be evaluated during 
national approval 
N/A 
15.2 
Addition: 
Add ―and CLASS 0I EQUIPMENT‖ after the 
words, ―CLASS I EQUIPMENT‖ 
Class II equipment 
N/A 
Page 42 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
JP  Japan (H23) 
JP 
15.2 
Addition: 
Add  the  following  paragraphs  after  the  first 
paragraph. 
The  external  earth  wire  of  plug  with  an  external 
earth wire shall not be earthed by a clip. 
Rated  voltage  of  plug  with  an  protective  external 
earth wire shall be less 150 Vac. 
Class II equipment 
N/A 
Deletion: 
Delete the following paragraph. 
In  SUPPLY  APPARATUS  of  CLASS  I  with  non-
HAZARDOUS  
LIVE  output  voltage,  output 
circuits  shall  not  be  connected  to  the  protective 
earthing conductor. 
 
N/A 
15.3.1 
Replacement: 
In the first paragraph, replace 
―IEC 60998-2-2‖ by 
― IEC 60998-2-2 or JIS C 2814-2-2:2001‖. 
 
N/A 
Replacement: 
In the first paragraph, replace 
―IEC 60999‖ by 
―IEC 60999-1‖. 
 
N/A 
Replacement: 
In the third paragraph, replace 
―IEC 60335-1‖ by 
―JIS C 9335-1:2003 (corresponding to IEC 
60335-1)
‖. 
 
N/A 
15.3.3 
Replacement: 
Replace ―ISO 261 or ISO 262‖ by ―JIS B 0205-
2:2001 or JIS B 0205-3
:2001‖. 
 
N/A 
15.3.5 
Replacement: 
In the second paragraph, replace 
―IEC 60950‖ by 
―JIS C 6950:2006‖. 
 
N/A 
15.3.5 
Replacement: 
Replace Table 15 by the following. 
 
Should be evaluated during 
national approval 
N/A 
Page 43 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
JP  Japan (H23) 
JP 
15.3.9 
Addition: 
Add the following to the last of the first paragraph. 
This does not apply to CLASS 0I EQUIPMENT 
with a protective earthing terminal separately. 
 
N/A 
15.4.1 
Replacement: 
In NOTE 1, replace 
―IEC 60884-1‖ by ―JIS C 8282 
(corresponding to IEC 60884-1)
‖. 
 
N/A 
Replacement: 
In NOTE 2, replace 
―IEC 60083 [1]‖ by ―JIS C 
8303
‖. 
 
N/A 
15.4.2 
Replacement: 
In NOTE, replace 
―IEC 60083 [1]‖ by ―JIS C 
8303:1993 [1]
‖. 
 
N/A 
15.4.3 
Addition: 
Add the following NOTE to Table 17. 
NOTE  If mains plug is parallel blade, a pull force 
as given in  ―Over 10 A up to and including 16 A, 
130/250 V
‖ of Table 17 is applied. 
Should be evaluated during 
national approval 
N/A 
16.1 
Addition: 
Add the following to the last of first paragraph. 
Or  mains  cords  shall  be  of  the  sheathed  type 
complying  with  Appendix  1  of  Article  1  of  the 
Ministerial  Ordinance  on  stipulating  technical 
requirements for the Electrical Appliance..  
Replacement: 
Replace the second paragraph by the 
following. 
Compliance  is  checked  by  testing  MAINS  supply 
flexible  cords  in  accordance  with  JIS  C  3662 
(corresponding  to  IEC60227)  or  JIS  C  3663 
(corresponding  to  IEC  60245),  or  Appendix  1  of 
Article  1  of  the  Ministerial  Ordinance  on 
stipulating 
technical 
requirements 
for 
the 
Electrical Appliance.   
Should be evaluated during 
national approval 
N/A 
Replacement: 
In this sub-clause, replace 
―IEC 60227‖ by ―JIS C 
3662 (corresponding to IEC 60227)
‖. 
In this sub-clause, replace 
―IEC 60245‖ by ―JIS C 
3663 (corresponding to IEC 60245)
‖. 
Should be evaluated during 
national approval 
N/A 
Page 44 of 69  
Report Reference No.: 211-2012016-000 
Attachment No. 2
 
IEC60065 
Clause 
Requirement + Test 
Result - Remark 
Verdict 
 
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch 
 
 Test Report National and Group Differences for IEC 60065 7
th
 Ed.+A1+A2 Rev. 02/ 2011-06 
JP  Japan (H23) 
JP 
Addition: 
Add  the  following  paragraph  after  the  third 
paragraph. 
An external earth wire of Class 0I equipment shall 
be  green/yellow,  and  the  length  of  external  earth 
wire  of  plug  with  an  external  earth  wire  shall  be 
equal or more than 10 cm from the plug. 
Class II equipment 
N/A 
 
16.2
 
Replacement: 
Replace the first paragraph by the following. 
Power supply cord conductors complied with JIS 
C 3662 (corresponding to IEC 60227) or JIS C 
3663 (corresponding to IEC 60245) shall have a 
nominal cross-sectional area not less than those 
shown in table 18. If power supply cord 
conductors comply with other standards, it shall 
comply with relevant wiring requirements.
 
Should be evaluated during 
national approval 
N/A 
16.2 
Replacement: 
Replace Table 18 by the following.
 
 
Should be evaluated during 
national approval 
N/A 
16.3 
Replacement: 
In item a), replace 
―IEC 60885-1‖ by ―JIS C 3661-
1:1998
‖. 
 
N/A 
Replacement: 
In item b), replace 
―IEC 60227-2‖ by ―JIS C 3662-
2 (corresponding to IEC 60227-2)
‖. 
 
N/A 
16.5 
Addition: 
Add ―or CLASS 0I EQUIPMENT used a plug with 
an external earth wire‖ after the words, CLASS I 
EQUIPMENT. 
 
Class II equipment 
N/A 
Annex 
Replacement: 
Replace normative by Informative. 
 
 
N/A 
Annex 
Replacement: 
Replace IEC 60707 by JIS C 0066:2001 
Replace  IEC  60695-2-2  by  JIS  C  60695-2-
2:2000. 
Replace IEC 60695-11-10 by JIS Z 2391:1999. 
 
 
 
 
N/A 
Page of 127
Display