Harman Kardon BDS 575 EMC - CB Certificate ▷ View online
Page 41 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
JP Japan (H23)
JP
15.1.1
Replacement:
Replace the paragraph after NOTE 2 by the
following.
following.
MAINS
socket-outlets
and
interconnection
couplers mounted on CLASS 0I and CLASS II
apparatus shall not permit connection of CLASS I
apparatus.
apparatus shall not permit connection of CLASS I
apparatus.
N/A
15.1.1
Replacement:
Replace the paragraph before NOTE 3 by the
following.
following.
MAINS
socket-outlets
and
interconnection
couplers mounted on CLASS I apparatus shall be
provided with protective earthing contacts which
are reliably connected to the PROTECTIVE
EARTHING TERMINAL or contact of the
apparatus. If not, it shall not permit connection of
CLASS I apparatus.
provided with protective earthing contacts which
are reliably connected to the PROTECTIVE
EARTHING TERMINAL or contact of the
apparatus. If not, it shall not permit connection of
CLASS I apparatus.
N/A
Replacement:
Replace NOTE 4 by the following.
NOTE 4 Socket-outlets not allowing the
connection of CLASS I apparatus can be
designed, for instance, similar to IEC 60906-1,
standard sheets 3-1 or 3-2, or according to IEC
60320-2-2, standard sheets D or H.
connection of CLASS I apparatus can be
designed, for instance, similar to IEC 60906-1,
standard sheets 3-1 or 3-2, or according to IEC
60320-2-2, standard sheets D or H.
N/A
15.1.2
Deletion:
Delete the following sentence in NOTE.
An example of a connector not meeting the
requirements of this sub clause is the so-called
"banana" plug.
requirements of this sub clause is the so-called
"banana" plug.
N/A
15.1.3
Replacement:
Replace the references, ―IEC 60083 [1], IEC
60320, IEC 60884, IEC 60906‖ by ―JIS C 8282
(corresponding to IEC 60884), JIS C 8303, IEC
60320 and IEC 60906‖.
60320, IEC 60884, IEC 60906‖ by ―JIS C 8282
(corresponding to IEC 60884), JIS C 8303, IEC
60320 and IEC 60906‖.
Should be evaluated during
national approval
national approval
N/A
15.2
Addition:
Add ―and CLASS 0I EQUIPMENT‖ after the
words, ―CLASS I EQUIPMENT‖
words, ―CLASS I EQUIPMENT‖
Class II equipment
N/A
Page 42 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
JP Japan (H23)
JP
15.2
Addition:
Add the following paragraphs after the first
paragraph.
paragraph.
The external earth wire of plug with an external
earth wire shall not be earthed by a clip.
earth wire shall not be earthed by a clip.
Rated voltage of plug with an protective external
earth wire shall be less 150 Vac.
earth wire shall be less 150 Vac.
Class II equipment
N/A
Deletion:
Delete the following paragraph.
In SUPPLY APPARATUS of CLASS I with non-
HAZARDOUS
HAZARDOUS
LIVE output voltage, output
circuits shall not be connected to the protective
earthing conductor.
earthing conductor.
N/A
15.3.1
Replacement:
In the first paragraph, replace
―IEC 60998-2-2‖ by
― IEC 60998-2-2 or JIS C 2814-2-2:2001‖.
N/A
Replacement:
In the first paragraph, replace
―IEC 60999‖ by
―IEC 60999-1‖.
N/A
Replacement:
In the third paragraph, replace
―IEC 60335-1‖ by
―JIS C 9335-1:2003 (corresponding to IEC
60335-1)
60335-1)
‖.
N/A
15.3.3
Replacement:
Replace ―ISO 261 or ISO 262‖ by ―JIS B 0205-
2:2001 or JIS B 0205-3
2:2001 or JIS B 0205-3
:2001‖.
N/A
15.3.5
Replacement:
In the second paragraph, replace
―IEC 60950‖ by
―JIS C 6950:2006‖.
N/A
15.3.5
Replacement:
Replace Table 15 by the following.
Should be evaluated during
national approval
national approval
N/A
Page 43 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
JP Japan (H23)
JP
15.3.9
Addition:
Add the following to the last of the first paragraph.
This does not apply to CLASS 0I EQUIPMENT
with a protective earthing terminal separately.
with a protective earthing terminal separately.
N/A
15.4.1
Replacement:
In NOTE 1, replace
―IEC 60884-1‖ by ―JIS C 8282
(corresponding to IEC 60884-1)
‖.
N/A
Replacement:
In NOTE 2, replace
―IEC 60083 [1]‖ by ―JIS C
8303
‖.
N/A
15.4.2
Replacement:
In NOTE, replace
―IEC 60083 [1]‖ by ―JIS C
8303:1993 [1]
‖.
N/A
15.4.3
Addition:
Add the following NOTE to Table 17.
NOTE If mains plug is parallel blade, a pull force
as given in ―Over 10 A up to and including 16 A,
130/250 V
as given in ―Over 10 A up to and including 16 A,
130/250 V
‖ of Table 17 is applied.
Should be evaluated during
national approval
national approval
N/A
16.1
Addition:
Add the following to the last of first paragraph.
Or mains cords shall be of the sheathed type
complying with Appendix 1 of Article 1 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance..
complying with Appendix 1 of Article 1 of the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance..
Replacement:
Replace the second paragraph by the
following.
following.
Compliance is checked by testing MAINS supply
flexible cords in accordance with JIS C 3662
(corresponding to IEC60227) or JIS C 3663
(corresponding to IEC 60245), or Appendix 1 of
Article 1 of the Ministerial Ordinance on
stipulating
flexible cords in accordance with JIS C 3662
(corresponding to IEC60227) or JIS C 3663
(corresponding to IEC 60245), or Appendix 1 of
Article 1 of the Ministerial Ordinance on
stipulating
technical
requirements
for
the
Electrical Appliance.
Should be evaluated during
national approval
national approval
N/A
Replacement:
In this sub-clause, replace
―IEC 60227‖ by ―JIS C
3662 (corresponding to IEC 60227)
‖.
In this sub-clause, replace
―IEC 60245‖ by ―JIS C
3663 (corresponding to IEC 60245)
‖.
Should be evaluated during
national approval
national approval
N/A
Page 44 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
JP Japan (H23)
JP
Addition:
Add the following paragraph after the third
paragraph.
paragraph.
An external earth wire of Class 0I equipment shall
be green/yellow, and the length of external earth
wire of plug with an external earth wire shall be
equal or more than 10 cm from the plug.
be green/yellow, and the length of external earth
wire of plug with an external earth wire shall be
equal or more than 10 cm from the plug.
Class II equipment
N/A
16.2
Replacement:
Replace the first paragraph by the following.
Power supply cord conductors complied with JIS
C 3662 (corresponding to IEC 60227) or JIS C
3663 (corresponding to IEC 60245) shall have a
nominal cross-sectional area not less than those
shown in table 18. If power supply cord
conductors comply with other standards, it shall
comply with relevant wiring requirements.
C 3662 (corresponding to IEC 60227) or JIS C
3663 (corresponding to IEC 60245) shall have a
nominal cross-sectional area not less than those
shown in table 18. If power supply cord
conductors comply with other standards, it shall
comply with relevant wiring requirements.
Should be evaluated during
national approval
national approval
N/A
16.2
Replacement:
Replace Table 18 by the following.
Should be evaluated during
national approval
national approval
N/A
16.3
Replacement:
In item a), replace
―IEC 60885-1‖ by ―JIS C 3661-
1:1998
‖.
N/A
Replacement:
In item b), replace
―IEC 60227-2‖ by ―JIS C 3662-
2 (corresponding to IEC 60227-2)
‖.
N/A
16.5
Addition:
Add ―or CLASS 0I EQUIPMENT used a plug with
an external earth wire‖ after the words, CLASS I
EQUIPMENT.
an external earth wire‖ after the words, CLASS I
EQUIPMENT.
Class II equipment
N/A
Annex
B
B
Replacement:
Replace normative by Informative.
N/A
Annex
G
G
Replacement:
Replace IEC 60707 by JIS C 0066:2001
Replace IEC 60695-2-2 by JIS C 60695-2-
2:2000.
2:2000.
Replace IEC 60695-11-10 by JIS Z 2391:1999.
N/A