Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
FI Finland
FI
5.3
Amendment A2 (2010)
To the end of the subclause the following is
added:
CLASS I apparatus which is intended for
connection to the building installation wiring via a
plug or an appliance coupler, or both and in
addition is intended for connection to other
apparatus or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
TERMINALS and ACCESSIBLE parts, have a
marking stating that the apparatus must be
connected to an earthed MAINS socket-outlet.
The marking text in the applicable countries shall
be as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
To the end of the subclause the following is
added:
CLASS I apparatus which is intended for
connection to the building installation wiring via a
plug or an appliance coupler, or both and in
addition is intended for connection to other
apparatus or a network shall, if safety relies on
connection to protective earth or if surge
suppressors are connected between the network
TERMINALS and ACCESSIBLE parts, have a
marking stating that the apparatus must be
connected to an earthed MAINS socket-outlet.
The marking text in the applicable countries shall
be as follows:
In Finland: "Laite on liitettävä suojakoskettimilla
varustettuun pistorasiaan"
―Apparaten skall anslutas till jordat uttag‖
N/A
GB United Kingdom
GB
15.1.1
Apparatus which is fitted with a flexible cable or
cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ‖standard plug‖ in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets
etc. (Safety) Regulations 1994, unless exempted
by those Regulations.
cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ‖standard plug‖ in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets
etc. (Safety) Regulations 1994, unless exempted
by those Regulations.
NOTE ‖Standard plug‖ is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved
conversion plug.
and essentially means an approved plug
conforming to BS 1363 or an approved
conversion plug.
Justification:
SI 1768: 1994
P
Page 34 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
JP Japan (H23)
JP
1.1.3
Addition:
Add the following as a NOTE after the first
sentence.
NOTE 1 In Japan, the requirements for
regions with moderate apply.
Add the following as a NOTE after the first
sentence.
NOTE 1 In Japan, the requirements for
regions with moderate apply.
Should be evaluated during national
approval
approval
N/A
2.4.9
Replacement:
In NOTE 1, replace “see 4.2.2 of IEC 62151” by
“see 4.2.2 of IEC 62151 [27]”.
“see 4.2.2 of IEC 62151 [27]”.
N/A
2.6.2A
Addition:
Add this sub clause.
CLASS 0I EQUIPMENT: Equipment which has,
as for protection against electric shock,
as for protection against electric shock,
- at least using BASIC INSULATION, and
- providing a means of connecting to the
protective earthing conductor in the building
wiring those conductive parts that are
otherwise capable of assuming HAZARDOUS
VOLTAGES if the BASIC INSULATION fails,
and
wiring those conductive parts that are
otherwise capable of assuming HAZARDOUS
VOLTAGES if the BASIC INSULATION fails,
and
- using
a supply
cord
without earthing
conductor or a plug without earthing pin.
Apparatus provided with a cord set having a two-
pin type plug with a lead wire for earthing or
having three pin - tow pin adaptor is also
regarded as Class 0I.
pin type plug with a lead wire for earthing or
having three pin - tow pin adaptor is also
regarded as Class 0I.
NOTE Class 0I equipment may have a part
constructed with Double Insulation or Reinforced
Insulation.
constructed with Double Insulation or Reinforced
Insulation.
Class II equipment
N/A
3.2
Addition:
Add the ―Class 0I equipment‖ in the first sentence
of this sub-clause.
of this sub-clause.
Class II equipment
N/A
3.2
Addition:
Add the following after the first sentence of this
sub-clause.
sub-clause.
NOTE Equipment often transported and used
should not be Class I equipment nor Class 0I
equipment.
should not be Class I equipment nor Class 0I
equipment.
N/A
4.2.8
Deletion:
Delete this clause.
N/A
4.3.4, b) Replacement:
Replace IEC 60730-1 by JIS C 9730-1
(corresponding to IEC 60730-1).
(corresponding to IEC 60730-1).
N/A
Page 35 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
JP Japan (H23)
JP
4.3.12
Deletion:
Delete this clause.
N/A
4.3.13
Replacement:
Replace ―250 V a.c.‖ by ―the maximum of the
variable range‖.
variable range‖.
N/A
5.4.2A
Addition:
For CLASS 0I EQUIPMENT, the following
instruction shall be indicated where readily visible
on the mains plug or the product:
instruction shall be indicated where readily visible
on the mains plug or the product:
―WARNING: Provide an earthing connection‖
Example in Japanese:
Moreover, for CLASS 0I EQUIPMENT, the
following instruction shall be indicated where
readily visible on the product or written in the
operating instructions:
following instruction shall be indicated where
readily visible on the product or written in the
operating instructions:
―WARNING: Provide an earthing connection
before the mains plug is connected to the mains.
And,
before the mains plug is connected to the mains.
And,
when
disconnecting
the
earthing
connection, be sure to disconnect after pulling
out the mains plug from the mains.‖
out the mains plug from the mains.‖
Example in Japanese:
Class II equipment
N/A
6.2
Replacement:
In NOTE 1, replace IEC 61040 [10] by JIS C
6181:1995 [10].
6181:1995 [10].
P
7.1.5
Addition:
Add the words, ―without dimensions restrictions‖
after the figure, ―65 K‖ in the first sentence of
Condition ―b‖ in Table 3 as follows.
after the figure, ―65 K‖ in the first sentence of
Condition ―b‖ in Table 3 as follows.
For parts not likely to be touched during intended
use, temperature rises up to 65 K without
dimensions restrictions are allowed under normal
operating conditions.
use, temperature rises up to 65 K without
dimensions restrictions are allowed under normal
operating conditions.
P
Page 36 of 69
Report Reference No.: 211-2012016-000
Attachment No. 2
IEC60065
Clause
Requirement + Test
Result - Remark
Verdict
Jiangsu TÜV Product Service Ltd. - Shenzhen Branch
Test Report National and Group Differences for IEC 60065 7
th
Ed.+A1+A2 Rev. 02/ 2011-06
JP Japan (H23)
JP
Addition:
Add the following paragraph as 2
nd
paragraph of
Condition ―d ―in Table 3.
For materials which are not listed in Table 3,
temperature rises in the normal operating
conditions are considered satisfactory if these
materials comply with item 3 of detailed
regulations, 1.(1),b, Appendix 4 in the Ministerial
Ordinance on stipulating technical requirements
for the Electrical Appliance and Material.
Permissible temperature rise of ―Supply cords
and wiring insulation‖ is applicable only to the
materials used in supply cords complying with
JIS C 3662 (corresponding to IEC 60227) or JIS
C 3663 (corresponding to IEC 60245). Materials
used in other wiring shall comply with item 3 of
detailed regulations, 1.(1).b, Appendix 4 in the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material.
temperature rises in the normal operating
conditions are considered satisfactory if these
materials comply with item 3 of detailed
regulations, 1.(1),b, Appendix 4 in the Ministerial
Ordinance on stipulating technical requirements
for the Electrical Appliance and Material.
Permissible temperature rise of ―Supply cords
and wiring insulation‖ is applicable only to the
materials used in supply cords complying with
JIS C 3662 (corresponding to IEC 60227) or JIS
C 3663 (corresponding to IEC 60245). Materials
used in other wiring shall comply with item 3 of
detailed regulations, 1.(1).b, Appendix 4 in the
Ministerial Ordinance on stipulating technical
requirements for the Electrical Appliance and
Material.
P
Addition:
In the first paragraph of Condition ―f‖ of Table 3,
add ‖JIS K 7206:1999 or‖ before the reference,
ISO 306.
add ‖JIS K 7206:1999 or‖ before the reference,
ISO 306.
P
Addition:
In Condition ―f,‖ 1) of Table 3, add ‖JIS K
7206:1999 or‖ before the reference, ISO 306.
7206:1999 or‖ before the reference, ISO 306.
P
7.2
Addition:
In NOTE 2, add
‖or JIS standard (identical to or
modified IEC)
‖ after the word, IEC standard.
N/A
8.5
Addition:
In the first paragraph, add ―and Class 0I
Equipme
Equipme
nt‖ after the words, Class I Equipment.
Class II equipment
N/A
8.5
Addition:
In the six paragraph (before NOTE 3), add the
following to the end of the first sentence.
following to the end of the first sentence.
CLASS 0I EQUIPMENT shall be provided with a
protective earthing terminal at any point outside
the apparatus where easily visible or a protective
external earth wire from mains plug.
protective earthing terminal at any point outside
the apparatus where easily visible or a protective
external earth wire from mains plug.
Class II equipment
N/A
8.11
Addition:
In
NOTE 2, c), add ―or JIS C 2107, JIS C 2336,
JIS C 2338‖ after the reference, IEC 60454.
P