DOWNLOAD Harman Kardon AVR 507 (serv.man2) Service Manual ↓ Size: 1.66 MB | Pages: 50 in PDF or view online for FREE

Model
AVR 507 (serv.man2)
Pages
50
Size
1.66 MB
Type
PDF
Document
EMC - CB Certificate
Brand
Device
Audio
File
avr-507-sm2.pdf
Date

Harman Kardon AVR 507 (serv.man2) EMC - CB Certificate ▷ View online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 5 of 38 - 
 
 
   
 Order 
No. 
11152
 
 
 
 
Standardized approval marks   
 
 
1  
SCOPE   
According to the standard 
 
2  
DEFINITIONS   
According to the standard 
 
3  
GENERAL REQUIREMENTS  
According to the standard 
 
 
Safety class of the apparatus 
Class II 
 
4   
GENERAL CONDITIONS FOR 
TESTS  
According to the standard 
 
4.1.4 - 
4.2.12. 
Normal operating 
conditions/position/adjustments 
With all users controls set to obtain maximum power from 
the mains and at 1/8 of max. audio output power. 
Positioned according to users manual. 
 
MARKING AND INSTRUCTIONS 
 
 
Copy of the markings :
 
 
 
 
 
 
Comprehensible and easily 
discernible  
On front and rear side of the enclosure 
 
Permanent durability against water 
and petroleum spirit   
Tested with water / spirit 
 
5.1 
Identification, maker, model      
 
 
Class II symbol   
 
 
Rated supply voltage and symbol      
AC-symbol ( 
~
 ) and 
230V 
 
Rated mains frequency 
50Hz 
 
Rated current or power consumption
350W 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 6 of 38 - 
 
 
   
 Order 
No. 
11152
 
 
 
 
5.2 
Earth terminal   
Class II apparatus 
 
Hazardous live terminals   
No live parts accessible 
 
Supply output terminals (other than 
mains)  
The power is marked close to the socket outlet; 
”AC OUTLETS (~230V/50Hz),   
UNSWITCHED (100W MAX),   
SWITCHED (50W MAX)” 
5.3 
Use of triangle with exclamation 
mark         
         
(Symbol ISO 7000-0434)   
Correct symbol applied: Imprinted on rear side in 
connection with CAUTION of opening. Further; no 
incorrect use of this symbol is found. 
5.4 
Instructions for use   
 
5.4.1 
Mains powered equipment not 
exposed to dripping or splashing   
Adequate instructions supplied. 
   
 
Hazardous live terminals, 
instructions for wiring   
No live terminal. 
 
 
Instructions for replacing lithium 
battery  
No lithium battery 
 
 
Explanation of marking of the 
manually operated mechanical 
switch (MOMS)   
No explanation required (indication in the form of 
illumination) 
 
5.4.2 
Instructions for permanently 
connected equipment   
If not completely switched OFF from 
the mains, info required 
The apparatus is not for permanent connection 
 
6 HAZARDOUS 
RADIATION 
 
 
No radiation 
6.1 
High voltage (kV).   
 
 
Focus voltage (kV)   
 
 
Amount of radiation     
 
6.2 
Non-ionizing radiation (laser 
radiation)  
 
6.2.1 
Opening of any cover by hand   
 
 
Mechanical interlocking device   
 
 
Accessible emission normal 
operation / classification   
 
 Labelling 
 
 
6.2.2 
Accessible emission fault condition 
outside / inside 
 
 
Warning label requirement   
 
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 7 of 38 - 
 
 
   
 Order 
No. 
11152
 
 
 
 
HEATING UNDER NORMAL 
OPERATING CONDITIONS   
 
 
Power consumption in the 
OFF/Stand-by mode (ref. 14.6.2) 
Position of the functional switch (W) 
In OFF/Stand-by position, the power consumption is less 
than 15W. 
 
Surge current needed in clause 14.6 
when testing mains switches or 
functional switches conductively 
connected to the supply mains. 
(Note! Mains socket-outlet Clause 
14.6.10.) 
Ref. clause 14.6. 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 8 of 38 - 
 
 
   
 Order 
No. 
11152
 
 
 
 
7.1  
 
 
Standby mode: 
 U 
= 
207,0
 V, I 
= 
0,012
 A, P 
= 
2,0 
W, 
Pout = 
 
W 
 U 
= 
230,0
 V, I 
= 
0,012
 A, P 
= 
2,3 
W, 
Pout = 
 
W 
U = 
254,4
 V, I 
= 
0,012
 A, P 
= 
2,7 
W, 
Pout = 
 
W 
 
Measured at maximum non-clipped output:   
 U 
= 
207,0
 V, I 
= 
 
3,56
 A, P 
= 
596 
W, 
Pout = 
2 x 67,6 
(F)
 
   
 
 
 
 
 
 
1 x 67,4
 W 
(C)
 
   
 
 
 
 
 
 
2 x 62,6
 W 
(S) 
 
 
  
  
  
71,4
 W 
(S/M)
 
 U 
= 
230,0
 V, I 
= 
 
3,76
 A, P 
= 
696
 
W, 
Pout = 
2 x 67,6 
(F)
 
   
 
 
 
 
 
 
1 x 67,4
 W 
(C)
 
   
 
 
 
 
 
 
2 x 62,6
 W 
(S) 
 
 
  
  
  
71,4
 W 
(S/M)
 
U = 
254,4
 V, I 
= 
 
3,80
 A, P 
= 
774 
W, 
Pout = 
2 x 67,6 
(F)
 
   
 
 
 
 
 
 
1 x 67,4
 W 
(C)
 
   
 
 
 
 
 
 
2 x 62,6
 W 
(S) 
 
 
  
  
  
71,4
 W 
(S/M)
 
 
 
 
LSL =
  7 channels x 8
 
 
 
Measured at 1/8 of maximum non-clipped output:   
 U 
= 
207,0
 V, I 
= 
 
1,71
 A, P 
= 
262 
W, 
Pout = 
2 x 8,5 
(F)
 
 
 
 
 
 
 
 
 
1 x 8,4
 W 
(C)
 
 
 
 
 
 
 
 
 
2 x 7,8
 W 
(S) 
 
 
  
  
  
8,9
 W 
(S/M)
 
 U 
= 
230,0
 V, I 
= 
 
1,75
 A, P 
= 
297 
W, 
Pout = 
2 x 8,5 
(F)
 
 
 
 
 
 
 
 
 
1 x 8,4
 W 
(C)
 
 
 
 
 
 
 
 
 
2 x 7,8
 W 
(S) 
 
 
  
  
  
8,9
 W 
(S/M)
 
 U 
= 
254,4
 V, I 
= 
 
1,79
 A, P 
= 
334 
W, 
Pout = 
2 x 8,5 
(F)
 
 
 
 
 
 
 
 
 
1 x 8,4
 W 
(C)
 
 
 
 
 
 
 
 
 
2 x 7,8
 W 
(S) 
 
 
  
  
  
8,9
 W 
(S/M)
 
 
 
 
LSL =
  7 channels x 8
 
 
 
Page of 50
Display

Click on the first or last page to see other AVR 507 (serv.man2) service manuals if exist.