IEC 60065, 6th edition : 1998
 - 
- Page 33 of 38 - 
 
 
   
 Order 
No. 
11152
 
 
 
 
 
LIST OF CRITICAL COMPONENTS 
 
Part No 
Component/ 
Object 
Manufacturer 
Type / Model 
Ratings / 
Technical Data 
Complies 
with the 
following 
standard 
Marks of 
conformity 
granted **
For 
CENELEC 
Countries 
Mains plug   
with cord   
Kenic Electric Mfg. 
KE-21 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
 
alt. Phino 
Electrical 
Wire & Cable 
PHP-205 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
 
alt. 
Kuk Je Tong shin 
KKJ-1004A 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
 
alt. 
Volex (Asia) Pte. 
Ltd. 
M4206 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
 
alt. Korea 
KDK KKP-419C 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
 
alt. 
Kenic Electric Mfg. 
KE-32 
H03VVH2-F 
2.5A/250V 
6A/250V  
IEC60884-1
VDE 
For U.K. 
Mains plug 
with cord 
PHINO Electronics 
Co., Ltd 
PHP-307F 
H03VVH2-F 
13A/250V
(5A fused) 
6A/250V  
BS1363 
BS6500 
BSI 
 
alt. 
Volex (Asia) Pte Ltd.
MP5004A 
H03VVH2-F 
13A/250V
(5A fused) 
6A/250V  
BS1363 
BS6500 
BSI 
 
alt. 
Winbo Industries 
MS 323N 
H03VVH2-F 
13A/250V
(5A fused) 
6A/250V  
BS1363 
BS6500 
BSI 
 
alt. Luen 
Tai 
(IP’S)
 Elect.
Kenic Electric Mfg. 
9518 
H05VVH2-F 
13A/250V
(5A fused) 
6A/250V  
BS1363 
BS6500 
BSI 
 
Main 
transformer 
 
Bobbin 
material 
 
Thermal fuse 
Seoul Electronics & 
Telecom Co., Ltd. 
 
Various 
 
 
Therm-O-Disc. 
KLT5W011ZE/ 
CLT5W011ZE 
 
PETP or 
equiv
.  
 
 
G4A51167C 
230V, Class E 
 
 
94V-0 
 
 
10A/250V, 167 
°
C
 
IEC60065 
clause 14.3
 
UL94 
 
 
IEC60691 
1.) 
 
 
UL 
 
 
VDE 
 
Sub 
transformer 
 
Bobbin 
material 
 
Thermal fuse 
Seoul Electronics & 
Telecom Co., Ltd. 
 
Various 
 
 
Uchihashi Estec Co.
KLT5J033ZE / 
CLT5J033ZE 
 
PETP or 
equiv.
   
 
 
423 
230V, Class E 
 
 
94V-0 
 
 
0.5A/250V 130 
°
C
 
IEC60065 
clause 14.3
 
UL94 
 
 
IEC60691 
1.) 
 
 
UL 
 
 
VDE 
SW01 
Mains switch 
POSTEC Electric. 
SDL1P-B 
5A/80A 250V 
IEC60065
 
IEC61058-1
VDE 
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 34 of 38 - 
 
 
   
 Order 
No. 
11152
 
 
 
 
 
LIST OF CRITICAL COMPONENTS (continued) 
 
Part No 
Component/ 
Object 
Manufacturer 
Type / Model 
Ratings / 
Technical Data 
Complies 
with the 
following 
standard 
Marks of 
conformity 
granted **
RY94 
Mains relay 
Original Electrome. 
SDT-S-112DMR
8A/120A 250V 
IEC60065 
IEC61058-1
SEMKO 
F901, F902 
Outlet fuse 
alt. 
alt. 
alt. 
Littelfuse B.V. 
Littelfuse Triad. 
Bel Fuse. 
Save Fusetech. 
0663 
LT-5 
MRT 
SR-5 
T2.5A 250V 
IEC60127 
VDE 
SEMKO 
VDE 
VDE 
F903, F904 
Sec. fuse 
alt. 
S
amjoo Fuse Co. Ltd. 
Littelfuse Inc. 
S51 
218 
008
 
SB 8A 250V 
UL198G 
UL 
UL 
F905, F906 
Mains fuse 
alt. 
alt. 
alt. 
alt. 
Samjoo Fuse Co. 
Littelfuse Ltd. 
Littelfuse B.V. 
Suzhou 
Littelfuse OVS 
Littelfuse Triad Inc. 
50T 
218 
06.3
 
218 
06.3
 
618 
50T 
T6.3A L 250V 
IEC60127 
VDE 
VDE 
VDE 
VDE 
SEMKO 
F907 Mains 
fuse 
alt. 
alt. 
alt. 
alt. 
Samjoo Fuse Co. 
Littelfuse Ltd. 
Littelfuse B.V. 
Suzhou 
Littelfuse OVS 
Littelfuse Triad Inc. 
50T 
218 
004
 
218 
004
 
618 
50T 
T4A L 250V 
IEC60127 
VDE 
VDE 
VDE 
VDE 
SEMKO 
C124 X-capacitor 
alt. 
alt. 
alt. 
Pilkor Electronics. 
ISKRA Elect. 
Okaya Electric Inc. 
Yuchang Electronics.
PCX2 335M 
KNB1530 
RE104 
WBU1942 
0.10uF 275V 
X2 
IEC60384-
14, 2
nd
 ed. 
FIMKO 
FIMKO 
VDE 
FIMKO 
C853 
(switch across) 
 
C904 
(relay across)
 
X-capacitor 
alt. 
alt.  
alt. 
alt. 
Du San Industrial. 
Netron Tech. 
Sam Wha Capacitor. 
Murata Mfg. 
Jyh Chung Elect. 
NU 
AA 
SC 
KH 
JY 
0.0047uF/250V, 
X1. 
IEC
60384-
14, 
2
nd
 ed. 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
OL91 Mains 
Socket-outlet 
Dae Ryung 
Electronics. 
A3-04-D006 2.5A/250V  IEC60884-1
NEMKO 
 DC 
Brush- 
less Fan 
SUNONWEALTH 
Electric Machine. 
KD1206PTS3 DC12V, 
0.8A 
16 CFM 
IEC60950 TUV 
 PCB 
base 
material 
Various 
Various 
Min 94V-1 
UL 796 
UL 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
**) Marks listed under “Marks of conformity granted” indicates that Nemko has verified certifications respectively 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 6.Edition : 1998 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 35 of 38 - 
 
 
   
 Order 
No. 
11152
 
 
 
 
 
FAULT CONDITION TESTS   
Ambient temperature   
25,5 °C 
Rated voltage   
230V~ 50Hz 
Remarks  
Comp. 
No 
Fault Test 
Short 
current 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
D104 
S-c 
254,4 
A - C 
30 min 
F907 
1,85 A 
Normal operating. 
Input current stabilised at 1,78A. 
R106
 
opened.  No hazard. 
C122 
S-c 
254,4 
4 hr 
F907 
2,18 A 
FL display off immediately. 
Input current stabilised at 1,94A. 
R101 damaged. 
Main transformer primary winding 
heated-up to 130K and stabilised. 
Dielectric strength test O.K. 
No hazard. 
Q104 
S-c 
254,4 
C - E 
1 hr 
F907 
1,84 A 
Normal operating. 
Input current stabilised at 1,80A. 
No component damaged. 
No hazard. 
Q104 
S-c 
254,4 
B - C 
4 hr 
F907 
2,15 A 
FL display off immediately. 
Input current stabilised at 1,97A. 
R101, Q104, D101, D102 damaged.
Main transformer primary winding 
heated-up to 123K and stabilised. 
Dielectric strength test O.K. 
No hazard. 
C119 
S-c 
254,4 
3 hr 
F907 
2,00 A 
FL display off immediately. 
Input current stabilised at 1,96A. 
Q104 damaged. 
Main transformer primary winding 
heated-up to 116K and stabilised. 
Dielectric strength test O.K. 
No hazard. 
C117 
S-c 
254,4 
20 min 
F907 
1,79 A 
Normal operating. 
Input current stabilised at 1,79A. 
No component damaged. 
No hazard. 
D991 
S-c 
207 
AC - + 
10 min 
F907 
F903 
F904 
- Normal 
operating. 
Input current stabilised at 1,64A. 
F904 opened.  No hazard. 
D991 
S-c 
254,4 
AC - + 
10 min 
F907 
F903 
F904 
- Normal 
operating. 
Input current stabilised at 1,76A. 
F904 opened.  No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 36 of 38 - 
 
 
   
 Order 
No. 
11152
 
 
 
 
 
FAULT CONDITION TESTS (continued) 
Comp. 
No 
Fault Test 
Short 
current 
Test time
Fuse No
Current 
through 
fuse 
Mains power/temperatures/results 
C902 S-c 
207  - 
10 
min 
F907 
F903 
F904 
Front, SB/MULTI channels signal 
output off immediately. 
Input current stabilised at 0,85 A. 
F903, F904 opened. 
No hazard. 
C902 S-c 
254,4 - 
10 
min 
F907 
F903 
F904 
Front, SB/MULTI channels signal 
output off immediately. 
Input current stabilised at 0,89 A. 
F903, F904 opened. 
No hazard. 
D992 
S-c 
207 
AC - + 
10 min 
F907 
F905 
F906 
- Normal 
operating. 
Input current stabilised at 1,70A. 
F906 opened. 
No hazard. 
D992 
S-c 
254,4 
AC - + 
10 min 
F907 
F905 
F906 
- Normal 
operating. 
Input current stabilised at 1,78A. 
F906 opened. 
No hazard. 
C915 S-c 
254,4 - 
10 
min 
F907 
F905 
F906 
Center, Surround channels signal 
output off immediately. 
Input current stabilised at 1,21A. 
F905, F906 opened. 
No hazard. 
Q803 
S-c 
207 
C - E 
10 min 
F907 
F905 
F906 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
F905, F906 opened. 
No hazard. 
Q803 
S-c 
254,4 
C - E 
10 min 
F907 
F905 
F906 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
F905, F906 opened. 
Q804 shorted. 
No hazard. 
Q803 
S-c 
254,4 
B - C 
10 min 
F907 
F905 
F906 
Unit shut down immediately. 
Input current stabilised at 0,01A. 
No component damaged. 
No hazard. 
C807 S-c 
254,4 - 
20 
min 
F907 
F905 
F906 
2,16 A 
Surround L channel signal output 
distorted immediately. 
Input current stabilised at 1,61A. 
R821 opened. 
No hazard. 
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
 