Harman Kardon AVR 507 (serv.man2) EMC - CB Certificate ▷ View online
-
IEC 60065, 6th edition : 1998
-
- Page 37 of 38 -
Order
No.
11152
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault Test
V
Short
current
current
Test time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
Q804
S-c
254,4
C - E
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
F905, F906 opened.
Q903, Q804 shorted.
No hazard.
Input current stabilised at 0,01A.
F905, F906 opened.
Q903, Q804 shorted.
No hazard.
Q804
S-c
254,4
B - C
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
C813 S-c
254,4 -
20
min
F907
F905
F906
F905
F906
1,56 A
Surround L channel signal output
off immediately.
Input current stabilised at 1,56A.
No component damaged.
No hazard.
off immediately.
Input current stabilised at 1,56A.
No component damaged.
No hazard.
D962
S-c
254,4
A - C
15 min
-
1,78 A
Sub transformer primary winding
heated-up to 109K thermal fuse
opened after 15 min.
Dielectric strength test O.K.
No hazard.
heated-up to 109K thermal fuse
opened after 15 min.
Dielectric strength test O.K.
No hazard.
C906
S-c
254,4
-
14 min
-
< 0,03 A
Mains relay off immediately.
Sub transformer primary winding
heated-up to 111K thermal fuse
opened after 14 min.
Dielectric strength test O.K.
No hazard.
Sub transformer primary winding
heated-up to 111K thermal fuse
opened after 14 min.
Dielectric strength test O.K.
No hazard.
C907
S-c
254,4
-
1 hr
-
< 0,02 A
Mains relay off immediately.
Sub transformer primary winding
heated-up to 80K and stabilised.
Dielectric strength test O.K.
No hazard.
Sub transformer primary winding
heated-up to 80K and stabilised.
Dielectric strength test O.K.
No hazard.
Fan
(Back cover)
Locked 254,4 -
5
hr
F907,
F903,
F904,
F905,
F906
F903,
F904,
F905,
F906
1,79 A
Normal operating.
The components are heated up to:
- Main transf. pr. winding : 70K
- Main transformer core
The components are heated up to:
- Main transf. pr. winding : 70K
- Main transformer core
: 57K
- Sub transf. pr. winding
: 55K
- Sub transformer core
: 42K
- D992 body
: 55K
- PWB near D992
: 58K
- Q803 body
: 63K
- PWB near Q804
: 60K
and stabilised.
Dielectric strength test OK.
No hazard.
Dielectric strength test OK.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
-
IEC 60065, 6th edition : 1998
-
- Page 38 of 38 -
Order
No.
11152
FAULT CONDITION TESTS (continued)
P
Comp.
No
No
Fault Test
V
Short
current
current
Test time
Fuse No
Current
through
fuse
through
fuse
Mains power/temperatures/results
Speaker
Terminal
Terminal
S-c 254,4
Surround
(
(
L - ch.)
10 min
F907
F905
F906
F905
F906
-
Unit shut down immediately.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Input current stabilised at 0,01A.
No component damaged.
No hazard.
Top cover
opening
opening
Blocked 254,4 -
5
hr
F907,
F903,
F904,
F905,
F906
F903,
F904,
F905,
F906
1,79 A
Normal operating.
The components are heated up to:
- Main transf. pr. winding : 81K
- Main transformer core
The components are heated up to:
- Main transf. pr. winding : 81K
- Main transformer core
: 66K
- Sub transf. pr. winding
: 65K
- Sub transformer core
: 55K
- D992 body
: 56K
- PWB near D992
: 58K
- Q803 body
: 66K
- PWB near Q804
: 58K
and stabilised.
Dielectric strength test OK.
No hazard.
Dielectric strength test OK.
No hazard.
Pmax
operating
Maximum
non-
clipped
output
signal
non-
clipped
output
signal
254,4 -
39
min F907,
F903,
F904,
F905,
F906
F904,
F905,
F906
3,80 A
The components are heated up to:
- Main transf. pr. Winding : 144K
- Main transformer core
- Main transf. pr. Winding : 144K
- Main transformer core
: 82K
- D992 body
: 81K
- PWB near D992
: 87K
- Q803 body
: 55K
- PWB near Q804
: 52K
and main transformer’s thermal fuse
opened after 39 min.
Dielectric strength test OK.
No hazard.
opened after 39 min.
Dielectric strength test OK.
No hazard.
F No = Fault Number, S-c = Short-circuit, Dis = Disconnection
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998 -
- Page 1 of 3 -
Order
No.
11152
APPENDIX
CENELEC EN 60065:1998
CENELEC COMMON MODIFICATIONS, SPECIAL NATIONAL CONDITIONS, NATIONAL
DEVIATIONS AND OTHER INFORMATION
DEVIATIONS AND OTHER INFORMATION
P
C = CENELEC common modification, S = Special National condition, D = National deviation, F = Other information
DE
= Germany, DK = Denmark, GB = United kingdom, FI = Finland, IE = Ireland, IT = Italy, NO = Norway, SE = Sweden.
P = Pass, F = Fail, N = Not applicable.
P = Pass, F = Fail, N = Not applicable.
1.1.1 C
Replace text in Note 1 by : This
standard can be used as a guide for
the testing of battery operated
apparatus.
standard can be used as a guide for
the testing of battery operated
apparatus.
N
2.6.1 S
(DK) Class I apparatus provided
with a plug not establishing earthing
continuity when inserted in Danish
socket-outlets, see 15.1.1.
with a plug not establishing earthing
continuity when inserted in Danish
socket-outlets, see 15.1.1.
Class II apparatus
N
3.1 C
Delete the note. Add the following
indent : exposure to excessive
sound pressures from headphones
or earphones.
indent : exposure to excessive
sound pressures from headphones
or earphones.
5 D
(DE) Marking in case of intrinsically
ionizing radiation, cathode-ray tubes
ionizing radiation, cathode-ray tubes
N
5 D
(IT) Marking and instruction
requirements
- power consumption (W) for TV
receivers
requirements
- power consumption (W) for TV
receivers
N
6.1 D
(DE) Limits for ionizing radiation, TV
receivers (max. 1
receivers (max. 1
µ
Sv/h)
N
15.1.1 C
Delete notes 1 and 2.
Add to note 4: Attention is drawn to
the fact that a standard is under
preparation (presently prEN 50074)
for socket-outlets which allow
connection of Class II appliances
only.
Add to note 4: Attention is drawn to
the fact that a standard is under
preparation (presently prEN 50074)
for socket-outlets which allow
connection of Class II appliances
only.
15.1.1 S
(DK) Mains plug according to Heavy
Current Regulations, Section 107-2-
D1
(DK) Mains socket outlets Cl.I
(DK) Mains socket outlets Cl.II
Current Regulations, Section 107-2-
D1
(DK) Mains socket outlets Cl.I
(DK) Mains socket outlets Cl.II
P
15.1.1 S
(IE) Mains plug, flexible cord,
according to statutory Instrument
525: 1997
according to statutory Instrument
525: 1997
P
15.1.1 S
(NO) Mains socket outlets CI.II
P
15.1.1 S
(GB) Mains plug, flexible cord,
according to statutory Instrument
1768: 1994
according to statutory Instrument
1768: 1994
P
- APPENDIX CENELEC EN60065:1998 TO IEC60065:1998 -
- Page 2 of 3 -
Order
No.
11152
15.2 C
Delete note 2
16.1 C
Delete note 1
16.2 C
Delete the note
20 C
Delete note 2
APPENDIX
ANNEX B (normative)
No TNV circuit
N
Annex B C
Delete note 2
B.5.4.1 S
(NO) Marking stating that the
apparatus must be connected to an
earthed mains socket outlet.
Applicable text is:
"Apparatet må kun tilkoples jordet
stikkontakt" or
"Jordet stikkontakt skal benyttes når
apparatet tilkoples datanett"
Swedish text can also be accepted.
apparatus must be connected to an
earthed mains socket outlet.
Applicable text is:
"Apparatet må kun tilkoples jordet
stikkontakt" or
"Jordet stikkontakt skal benyttes når
apparatet tilkoples datanett"
Swedish text can also be accepted.
B.5.4.1 S
(SE) Marking stating that the
apparatus must be connected to an
earthed mains socket outlet.
The marking text shall be in Swedish
and as follows:
"Apparaten skall anslutas till jordat
uttag när den ansluts till ett nätverk"
apparatus must be connected to an
earthed mains socket outlet.
The marking text shall be in Swedish
and as follows:
"Apparaten skall anslutas till jordat
uttag när den ansluts till ett nätverk"
B.5.4.1 e) C
Delete notes 1 and 2
B.8.1 C
Delete notes 1, 2 and 3
B.8.1 S
(DK) Method b) is permitted only for
PERMANENTLY CONNECTED
APPARATUS
PERMANENTLY CONNECTED
APPARATUS
B.8.1 S
(NO) Method b) is not permitted
B.8.2 C
Delete the note
B.14.12 C
Delete notes 1 and 2
B.14.12 S
(DK) The following note is added:
NOTE in Denmark the use of surge
suppressors between the
TELECOMMUNICATION
NETWORK and conductive
ACCESSIBLE parts or TERMINALS
which are considered to be
ACCESSIBLE, is allowed only for
PERMANENTLY CONNECTED
APPARATUS.
NOTE in Denmark the use of surge
suppressors between the
TELECOMMUNICATION
NETWORK and conductive
ACCESSIBLE parts or TERMINALS
which are considered to be
ACCESSIBLE, is allowed only for
PERMANENTLY CONNECTED
APPARATUS.
Click on the first or last page to see other AVR 507 (serv.man2) service manuals if exist.