Harman Kardon AVR 507 (serv.man2) EMC - CB Certificate ▷ View online

 - 
IEC 60065, 6th edition : 1998
 - 
- Page 13 of 38 - 
 
 
   
 Order 
No. 
11152
 
 
 
 
8.7 
Basic insulation between parts at 
35 V to 71 V (peak) a.c. or 60 V to 
120 V d.c. and accessible parts   
No parts at 35-71V(peak) a.c. or 60-120V d.c. 
 
 
Reinforced or double insulation 
between circuits operating at 
voltages between 35 V and 71 V 
(peak) a.c. or between 60 V and 
120 V d.c. and hazardous live parts 
at higher voltage   
No parts at 35-71V(peak) a.c. or 60-120V d.c. 
 
 
Separation by Class II isolating 
transformer  
Isolating transformer according to 14.3.2. (Class II) 
 
Separation by Class I transformer   
 
 
Separation by earthed conductive 
part  
 
8.8 
Basic or supplementary insulation 
 0,4 mm (mm)      
 
 
Reinforced insulation 
 0,4 mm 
(mm)    
Insulation in transformer, ref. 14.3. 
 
Thin sheet insulation used inside the 
enclosure
 
 
 
Basic or supplementary insulation, at 
least two layers, each meeting 10.3 
 
 
Basic or supplementary insulation, 
three layers any two of which meet 
10.3  
 
 
Reinforced insulation, two layers 
each of which meet 10.3   
 
 
Reinforced insulation, three layers 
any two which meet 10.3   
 
8.9 
Primary wiring : 
Adequate insulation between internal 
hazardous live conductors and 
accessible parts   
Double insulated. 
 
Secondary wiring : 
Adequate insulation between internal 
hazardous live parts and conductors 
connected to accessible parts   
Single insulated but safely anchored. 
 
8.10 
Class II apparatus : 
Double insulation between 
conductors connected to the mains 
and accessible parts   
Double insulated, tested according to 8.9. and 10.3. 
 
Class II apparatus : 
Double insulation between 
conductors connected to accessible 
parts and the mains   
 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 14 of 38 - 
 
 
   
 Order 
No. 
11152
 
 
 
 
8.11 
Detaching of wires   
 
 
 
 
No undue reduction of creepage or 
clearance distances if wires become 
detached  
Primary wires connected with multi-contact-housing
 
Vibration test carried out      
Vibration test considered not necessary   
8.12 
Adequate cross-sectional area of 
internal wiring to mains socket-
outlets  
Socket outlet fuses provided 
8.13 
Adequate fastening of windows, 
lenses, lamp covers etc. (push or 
pull test 20 N for 10 s)   
Adequately fastened. 
 
8.14 
Adequate fastening of covers (push 
or pull test 50 N, for 10 s)   
Covers adequately fastened with screws. 
 
8.15 
No risk of damage to the insulation 
of internal wiring due to hot parts or 
sharp edges   
Wires safely anchored away from parts with high 
temperature. 
 
8.16 
Apparatus designed to be supplied 
by special supply apparatus only.   
 
 
ELECTRIC SHOCK HAZARD 
UNDER NORMAL OPERATING 
CONDITIONS  
 
9.1.1 
Touch current expressed as voltages 
U1 and U2 in Annex D   
 
Location Measured 
U1 
V (peak) 
Measured U1 
V (DC) 
Measured U2 
V (peak) 
Limits : 
U1 Max 35V (peak) 
U1 Max 1.0V (DC) 
U2 Max 0.35V 
(peak) 
Pole 1 - RCA terminal 
< 0,69 V 
< 0,08 V 
Pass 
Pole 2 - RCA terminal 
< 0,57 V 
< 0,07 V 
Pass 
 
 
 
 
 
 
Discharge not exceeding 45 
µ
C  
No part or contact of a terminal with stored voltages 
between 60V - 15kV 
 
Energy of discharge not exceeding 
350 mJ   
No part or contact of a terminal with stored voltages 
exceeding 15kV 
 
Test with test finger according to test 
probe B of IEC 61 032 (20N) 
No access to hazardous live parts 
 
 
For class II constructions, test with 
test probe 13 of IEC 61 032 (3N) 
No access to hazardous live parts 
 
 
Clearances to circuits exceeding 
1000V a.c. or 1500V d.c.   
No voltages exceeding 1000V AC or 1500V DC. 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 15 of 38 - 
 
 
   
 Order 
No. 
11152
 
 
 
 
9.1.2 
No hazardous live shafts of knobs, 
handles or levers   
No live shafts, handles or levers 
9.1.3 
Ventilation holes tested by means of 
4 mm x 100 mm test pin   
No access for the test pin. 
 
9.1.4 
Terminal devices tested with 
1 mm x 20 mm test pin (10 N); test 
probe 16 of IEC 61 032   
Does not reach hazardous live parts 
 
 
Terminal devices tested with 
1 mm x 100 mm straight wire (1 N); 
test probe D of IEC 61 032   
Does not reach hazardous live parts 
 
9.1.5 
Pre-set controls tested with 
2.5 mm x 100 mm test pin (10 N); 
test probe C of IEC 61 032   
No preset controls 
 
9.1.6 
No shock hazard due to stored 
charge on withdrawal of the mains 
plug; voltage (V) after 2 s      
Less than 1 V after 2 sec.
 
 
If C is not greater than 0,1 
µ
F no test 
needed  
 
9.1.7 
Enclosure sufficiently resistant to 
external force 
 
 
 
Test probe 11 of IEC 61 032 for 10 s 
(50 N)   
Test with test finger results in no hazard. 
 
 
Test hook of fig. 4 for 10 s (20 N)   
Test with test hook results in no hazard. 
 Conductive 
enclosures: 
30 mm diameter test tool for 5 s (100 
or 250 N) 
Test with 100N results in no damage. 
9.2 
No hazard 2s after removing a cover 
by hand   
No cover removable by hand 
 - 
IEC 60065, 6th edition : 1998
 - 
- Page 16 of 38 - 
 
 
   
 Order 
No. 
11152
 
 
 
 
10 INSULATION 
REQUIREMENTS 
 
 
10.1 
Insulation resistance (M
) at least 
2 M
 min. after surge test for basic 
and 4 M
 min. for reinforced 
insulation    
> 4 M
 
 
10.2 
Humidity treatment 48 h or 120 h      
120 h (40
°
C). No impairment 
10.3 
Insulation resistance and dielectric 
strength   
 
Tested insulation 
Insulation   
Test voltage 
Voltage test 
Remarks 
 
resistance 
based on the 
(r.m.s.value) 
 
 
     (M Ohm) 
Operating 
 
 
 Meas- 
Min. 
Voltage 
 
 
 ured 
required 
(V) 
(V) 
 
Between the poles 
 
 
For rated mains 
 
 
of the circuit    
:
 
 
2  
voltages 
 150V 
   
   
directly connected 
 
 
r.m.s, 1410V pk 
 
 
to the supply 
 
 
 
 
 
mains 
> 2
 
For rated mains 
1500 V 
Pass 
 
 
 
voltages 
 150V 
 
 
 
 
 
r.m.s, 2120V pk 
 
 
Basic insulation 
:
 
 
  
Curve A,
 
 
   
   
  
 
Fig. 
 
 
Supplementary  
  
 
 
insulation   
 
:
 
 
  
Curve A,
 
 
   
   
  
 
Fig. 
 
 
Reinforced  
 
 
 
 
insulation               
:
 
> 100 
  
Curve B,
 
 
 3000 V 
Pass 
  
 
Fig. 
 
 
 
11 FAULT 
CONDITIONS 
 
 
11.1 
Electric shock hazard under fault 
conditions  
No electric shock hazard under fault conditions 
11.2 
Heating under fault condition 
 
 
 
No hazard from softening solder   
Neither danger of fire to surroundings nor abnormal 
heat developed 
 
 
No flaming more than 10s   
No flaming 
11.2.1 
Measurement of temperature rises   
See appended table, fault condition tests 
11.2.2 
Temperature rise of accessible parts   
See appended table, fault condition tests 
11.2.3 
Temperature rise of parts, other than 
windings, providing electrical insulation 
See appended table, fault condition tests 
 
Temperature rise of printed circuit 
boards (PCB) exceeding the limits of 
Table 2 by max. 100 K for max. 5 min   
No area where temperature exceeds 100K above limits
 
Page of 50