Harman Kardon AVR 370 (serv.man4) EMC - CB Certificate ▷ View online
Page 41 of 61
Report No.: 215445
TRF No. IEC60065K
No.
Component
Fault
Duration
of the test
Other results
(include description)
dT (K) / Component
dT (K)
Permitted
dT (K)
23. *),
#)
#)
PC96
(Pin3 to Pin4)
(Pin3 to Pin4)
SC 30
min
Normal
operated.
The operating mode changed to
LOW mode after 2 min 10 s.
FI stabilized at 1.46 A.
NCD. No hazard.
LOW mode after 2 min 10 s.
FI stabilized at 1.46 A.
NCD. No hazard.
N/A N/A
24. *),
#)
#)
PC94
(Pin1 to Pin2)
(Pin1 to Pin2)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.10 A.
NCD. No hazard.
FI stabilized at 0.10 A.
NCD. No hazard.
N/A N/A
25. *),
#)
#)
PC94
(Pin3 to Pin4)
(Pin3 to Pin4)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.10 A.
NCD. No hazard.
FI stabilized at 0.10 A.
NCD. No hazard.
N/A N/A
26. *),
#)
#)
PC91
(Pin1 to Pin2)
(Pin1 to Pin2)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.10 A.
NCD. No hazard.
FI stabilized at 0.10 A.
NCD. No hazard.
N/A N/A
27. *),
#)
#)
PC91
(Pin3 to Pin4)
(Pin3 to Pin4)
SC 30
min
Normal
operated.
The operating mode changed to
Low mode after 2 min 10 s.
FI stabilized at 1.46 A.
NCD. No hazard.
Low mode after 2 min 10 s.
FI stabilized at 1.46 A.
NCD. No hazard.
N/A N/A
28. *),
#)
#)
PC95
(Pin3 to Pin4)
(Pin3 to Pin4)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.08 A.
NCD. No hazard.
FI stabilized at 0.08 A.
NCD. No hazard.
N/A N/A
29. *),
#)
#)
PC95
(Pin1 to Pin2)
(Pin1 to Pin2)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.08 A.
NCD. No hazard.
FI stabilized at 0.08 A.
NCD. No hazard.
N/A N/A
30. *),
#)
#)
PC99
(Pin1 to Pin2)
(Pin1 to Pin2)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.09 A.
NCD. No hazard.
FI stabilized at 0.09 A.
NCD. No hazard.
N/A N/A
31. *),
#)
#)
PC99
(Pin3 to Pin4)
(Pin3 to Pin4)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.09 A.
NCD. No hazard.
FI stabilized at 0.09 A.
NCD. No hazard.
N/A N/A
32. *),
#)
#)
PC93
(Pin1 to Pin2)
(Pin1 to Pin2)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.09 A.
NCD. No hazard.
FI stabilized at 0.09 A.
NCD. No hazard.
N/A N/A
33. *),
#)
#)
PC93
(Pin3 to Pin4)
(Pin3 to Pin4)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.09 A.
NCD. No hazard.
FI stabilized at 0.09 A.
NCD. No hazard.
N/A N/A
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
*) Tested voltage 264 V
**) Tested voltage 198 V
Apparatus mode; #) HIGH mode ##) LOW mode
Page 42 of 61
Report No.: 215445
TRF No. IEC60065K
No.
Component
Fault
Duration
of the test
Other results
(include description)
dT (K) / Component
dT (K)
Permitted
dT (K)
34. *),
#)
#)
PC92
(Pin1 to Pin2)
(Pin1 to Pin2)
SC
10 min
Unit shut down immediately.
FI changed between
0.08 A and 0.09 A periodically.
NCD. No hazard.
FI changed between
0.08 A and 0.09 A periodically.
NCD. No hazard.
N/A N/A
35. *),
#)
#)
PC92
(Pin3 to Pin4)
(Pin3 to Pin4)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.08 A.
NCD. No hazard.
FI stabilized at 0.08 A.
NCD. No hazard.
N/A N/A
36. *),
#)
#)
DB91
(AC to “+”)
(AC to “+”)
SC
1 s
F901 opened immediately.
DB91 damaged.
No hazard.
DB91 damaged.
No hazard.
N/A N/A
37. *),
##)
##)
DB91
(AC to “+”)
(AC to “+”)
SC
1 s
F901 opened immediately.
No hazard.
No hazard.
N/A N/A
38. **),
#)
#)
DB91
(AC to “+”)
(AC to “+”)
SC
1 s
F901 opened immediately.
No hazard.
No hazard.
N/A N/A
39. *),
#)
#)
DB91
(AC to “-”)
(AC to “-”)
SC
1 s
F901 opened immediately.
No hazard.
No hazard.
N/A N/A
40. *),
#)
#)
C930
SC
1 s
F901 opened immediately.
DB91 damaged.
No hazard.
DB91 damaged.
No hazard.
N/A N/A
41. *),
##)
##)
C930
SC
1 s
F901 opened immediately.
No hazard.
No hazard.
N/A N/A
42. **),
#)
#)
C930
SC
1 s
F901 opened immediately.
No hazard.
No hazard.
N/A N/A
43. *),
#)
#)
D913
(A to C)
(A to C)
SC 30
min
Normal
operated.
The operating mode changed to
LOW mode after 2 min 20 s.
FI stabilized at 1.46 A.
NCD. No hazard.
LOW mode after 2 min 20 s.
FI stabilized at 1.46 A.
NCD. No hazard.
N/A N/A
44. *),
#)
#)
D932
(A to C)
(A to C)
SC 30
min
Normal
operated.
The operating mode changed to
Low mode after 2 min 20 s.
FI stabilized at 1.46 A.
NCD. No hazard.
Low mode after 2 min 20 s.
FI stabilized at 1.46 A.
NCD. No hazard.
N/A N/A
45. *),
#)
#)
D901
(A to C)
(A to C)
SC
1 s
F901 opened immediately.
DB91, D902 damaged.
No hazard.
DB91, D902 damaged.
No hazard.
N/A N/A
46. *),
#)
#)
D902
(A to C)
(A to C)
SC
1 s
F901 opened immediately.
DB91, D901 damaged.
No hazard.
DB91, D901 damaged.
No hazard.
N/A N/A
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
*) Tested voltage 264 V
**) Tested voltage 198 V
Apparatus mode; #) HIGH mode ##) LOW mode
Page 43 of 61
Report No.: 215445
TRF No. IEC60065K
No.
Component
Fault
Duration
of the test
Other results
(include description)
dT (K) / Component
dT (K)
Permitted
dT (K)
47. *),
#)
#)
C902
SC
1 s
F901 opened immediately.
D901 damaged.
No hazard.
D901 damaged.
No hazard.
N/A N/A
48. *),
##)
##)
C902
SC
1 s
F901 opened immediately.
D902 damaged.
No hazard.
D902 damaged.
No hazard.
N/A N/A
49. *),
#)
#)
D903
(A to C)
(A to C)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.10 A.
NCD. No hazard.
FI stabilized at 0.10 A.
NCD. No hazard.
N/A N/A
50. *),
#)
#)
IC92
(pin4 to pin7)
(pin4 to pin7)
SC
1 s
F901 opened immediately.
IC92, D917, D918 and Q903
damaged.
No hazard.
IC92, D917, D918 and Q903
damaged.
No hazard.
N/A N/A
51. *),
#)
#)
IC92
(pin4 to pin2)
(pin4 to pin2)
SC
1 s
F901 opened immediately.
IC92 and D916 damaged.
No hazard.
IC92 and D916 damaged.
No hazard.
N/A N/A
52. *),
#)
#)
D910
(A to C)
(A to C)
SC 30
min
Normal
operated.
The operating mode changed to
LOW mode after 2 min 10 s.
FI stabilized at 1.46 A.
NCD. No hazard.
LOW mode after 2 min 10 s.
FI stabilized at 1.46 A.
NCD. No hazard.
N/A N/A
53. *),
#)
#)
IC91
(pin6 to pin3)
(pin6 to pin3)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.08 A.
NCD. No hazard.
FI stabilized at 0.08 A.
NCD. No hazard.
N/A N/A
54. *),
#)
#)
D904
(A to C)
(A to C)
SC 30
min
Normal
operated.
The operating mode changed to
LOW mode after 2 min 10 s.
FI stabilized at 1.46 A.
NCD. No hazard.
LOW mode after 2 min 10 s.
FI stabilized at 1.46 A.
NCD. No hazard.
N/A N/A
55. *),
##)
##)
Q905
(D to S)
(D to S)
SC
1 s
F901 opened immediately.
No hazard.
No hazard.
N/A N/A
56. *),
#)
#)
Q803
(C to E)
(C to E)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.08 A.
Q804, R736 and R737
damaged. No hazard.
FI stabilized at 0.08 A.
Q804, R736 and R737
damaged. No hazard.
N/A N/A
57. *),
#)
#)
Q803
(C to B)
(C to B)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.08 A.
NCD. No hazard.
FI stabilized at 0.08 A.
NCD. No hazard.
N/A N/A
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
*) Tested voltage 264 V
**) Tested voltage 198 V
Apparatus mode; #) HIGH mode ##) LOW mode
Page 44 of 61
Report No.: 215445
TRF No. IEC60065K
No.
Component
Fault
Duration
of the test
Other results
(include description)
dT (K) / Component
dT (K)
Permitted
dT (K)
58. **),
#)
#)
Q804
(C to E)
(C to E)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.08 A.
Q803, R734 and R736
damaged.
No hazard.
FI stabilized at 0.08 A.
Q803, R734 and R736
damaged.
No hazard.
N/A N/A
59. *),
#)
#)
Q804
(C to B)
(C to B)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.08 A.
NCD. No hazard.
FI stabilized at 0.08 A.
NCD. No hazard.
N/A N/A
60. *),
#)
#)
C813
SC
30 min
SL speaker output off
immediately.
The operating mode changed to
LOW mode after 2 min 10 s.
FI stabilized at 1.31 A.
NCD. No hazard.
immediately.
The operating mode changed to
LOW mode after 2 min 10 s.
FI stabilized at 1.31 A.
NCD. No hazard.
N/A N/A
61. *),
#)
#)
Front L output
SC
10 min
All speakers output off
immediately except for Front
display normal operated.
FI stabilized at 0.20 A.
NCD. No hazard.
immediately except for Front
display normal operated.
FI stabilized at 0.20 A.
NCD. No hazard.
N/A N/A
62. *),
#)
#)
USB output
SC
20 min
Only USB output off
immediately.
The operating mode changed to
LOW mode after 2 min 10 s.
FI stabilized at 1.37 A.
NCD. No hazard.
immediately.
The operating mode changed to
LOW mode after 2 min 10 s.
FI stabilized at 1.37 A.
NCD. No hazard.
N/A N/A
63. *),
##)
##)
Speaker
outputs
outputs
Pmax
3 h
Speaker output switched on
and off periodically
(turn on: 10 min, off: 5 min).
FI changed between 0.29 A
and 3.27 A periodically.
Dielectric strength test.
No hazard.
and off periodically
(turn on: 10 min, off: 5 min).
FI changed between 0.29 A
and 3.27 A periodically.
Dielectric strength test.
No hazard.
See $) in the next page
for measured highest
temperature
for measured highest
temperature
64. *),
#)
#)
Top cover
opening
opening
Blocked
2 h
Normal operated.
The operating mode changed to
LOW mode after 2 min.
FI stabilized at 1.46 A.
Dielectric strength test.
No hazard.
The operating mode changed to
LOW mode after 2 min.
FI stabilized at 1.46 A.
Dielectric strength test.
No hazard.
See a), b) in the next
page for measured
temperature.
page for measured
temperature.
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
*) Tested voltage 264 V
**) Tested voltage 198 V
Apparatus mode; #) HIGH mode ##) LOW mode