Harman Kardon AVR 370 (serv.man4) EMC - CB Certificate ▷ View online
Page 29 of 61
Report No.: 215445
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
A
Annex A, Additional requirements for apparatus with protection against
splashing water
splashing water
A.5 Marking
and
instructions
N/A
A.5.1
j) Marked with IPX4 (IEC 60529), 5.4.1 a) does not
apply
apply
Not intended for outdoor use
N/A
A.10 Insulation
requirements
N/A
A.10.2
Splash and humidity treatment
N/A
A.10.2.1
Enclosure provides protection against splashing
water
water
N/A
A.10.2.2
Humidity treatment carried out for 7 days
N/A
B
Annex B, Apparatus to be connected to the TELECOMMUNICATION
NETWORKS
NETWORKS
Complies with IEC 62151 clause 1
No TNV circuits
N/A
Complies with IEC 62151 clause 2
N/A
Complies with IEC 62151 clause 3 but with 3.5.4
modified to 2.4.10 of this standard
modified to 2.4.10 of this standard
N/A
Complies with IEC 62151 clause 4 but with 4.1.2,
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
4.1.3 and 4.2.1.2 modified in accordance with annex
B of this standard
N/A
Complies with IEC 62151 cause 5 but with 5.3.1
modified in accordance with annex B of this
standard
modified in accordance with annex B of this
standard
N/A
Complies with IEC 62151 clause 6
N/A
Complies with IEC 62151 clause 7
N/A
Complies with IEC 62151 annex A, B and C
N/A
Page 30 of 61
Report No.: 215445
IEC 60065
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065K
L
ANNEX L, Additional requirements for electronic flash apparatus for
photographic purposes
photographic purposes
L. 5
Marking and instructions
N/A
L. 5.4
Instructions for battery chargers and Supply
apparatus indicating type or model number of flash
apparatus with which it is to be used
apparatus indicating type or model number of flash
apparatus with which it is to be used
No electronic flash apparatus
N/A
Instructions for flash apparatus indicating type or
model number of battery chargers or Supply
apparatus with which it is to be used
model number of battery chargers or Supply
apparatus with which it is to be used
N/A
L. 7
Heating under normal operating conditions
N/A
L7.1.5 &
L11.2.7
L11.2.7
Lithium batteries meet permissible temp rise in
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC
60086-4
Table 3, unless comply with 6.2.2.1 or 6.2.2.2 of IEC
60086-4
No lithium batteries
N/A
L. 9
Electric shock hazard under normal operating
conditions
conditions
Not flash synchroniser.
N/A
L. 9.1.1
Terminals to connection to synchroniser not
HAZARDOUS LIVE
HAZARDOUS LIVE
N/A
L.10 Insulation
requirements
N/A
L. 10.3.2
High frequency pulse ignition
N/A
L. 12
Mechanical strength
N/A
L. 12.1.3
Windows for flash tubes are excluded from steel ball
impact test
impact test
N/A
L. 14
Components
N/A
L14.6.6
Mains switch characteristics appropriate to its
function under normal conditions
function under normal conditions
N/A
L. 20
Resistance to fire
N/A
L. 20.1 c) Trigger coil for discharge purpose is not considered
to be a POTENTIAL IGNITION SOURCE
N/A
Page 31 of 61
Report No.: 215445
TRF No. IEC60065K
7.1
TABLE: temperature rise measurements:
P
Power consumption in the OFF/Stand-by mode of
the functional switch (W) ........................................ :
the functional switch (W) ........................................ :
Less than 0.44 W
—
Operating Condition / Status
Standby mode;
Cond.
Un (V)
Hz
In (A)
Pn (W)
Uout (V) rms
Pout (W)
1 220 50
0.086
0.32
-
-
2 240 50
0.070
0.35
-
-
3 264 50
0.076
0.41
-
-
4 220 60
0.076
0.32
-
-
5 240 60
0.083
0.37
-
-
6 264 60
0.091
0.44
-
-
**) Measured at maximum non-clipped output mode with loaded 5 V/2.1 A through USB terminal;
Cond.
Un (V)
Hz
In (A)
Pn (W)
Uout (V) rms
Pout (W)
7 198 50
4.49
584.0
F) 15.42 V x 2
SB) 15.19 V x 2
S) 15.70 V x 2
C) 15.36 V
SB) 15.19 V x 2
S) 15.70 V x 2
C) 15.36 V
F) 39.63 W x 2
SB) 38.46 W x 2
S) 41.08 W x 2
C) 39.32 W
SB) 38.46 W x 2
S) 41.08 W x 2
C) 39.32 W
8 264 50
3.25
572.8
9 198 60
4.31
582.0
10 264 60
3.20
570.0
*) Measured at 1/8 of maximum non-clipped output mode with loaded 5 V/2.1 A through USB terminal;
Cond.
Un (V)
Hz
In (A)
Pn (W)
Uout (V) rms
Pout (W)
11 198 50
3.14
404.4
F) 5.45 V x 2
SB) 5.37 V x 2
S) 5.55 V x 2
C) 5.43 V
SB) 5.37 V x 2
S) 5.55 V x 2
C) 5.43 V
F) 4.95 W x 2
SB) 4.81 W x 2
S) 5.13 W x 2
C) 4.92 W
SB) 4.81 W x 2
S) 5.13 W x 2
C) 4.92 W
12 220 50
2.90
403.0
13 240 50
2.65
402.0
14 264 50
2.36
401.3
15 198 60
3.07
406.5
16 220 60
2.82
404.5
17 240 60
2.59
402.8
18 264 60
2.33
401.6
Page 32 of 61
Report No.: 215445
TRF No. IEC60065K
Operating Condition / Status
**) Measured at 1/8 of maximum non-clipped output mode with loaded 5 V/2.1 A through USB terminal;
Cond.
Un (V)
Hz
In (A)
Pn (W)
Uout (V) rms
Pout (W)
19 198 50
1.88
231.2
F) 5.45 V x 2
SB) 5.37 V x 2
S) 5.55 V x 2
C) 5.43 V
SB) 5.37 V x 2
S) 5.55 V x 2
C) 5.43 V
F) 4.95 W x 2
SB) 4.81 W x 2
S) 5.13 W x 2
C) 4.92 W
SB) 4.81 W x 2
S) 5.13 W x 2
C) 4.92 W
20 220 50
1.74
231.3
21 240 50
1.60
231.5
22 264 50
1.44
231.9
23 198 60
1.83
230.8
24 220 60
1.69
230.6
25 240 60
1.56
230.5
26 264 60
1.40
230.5
Input measured at TF95 and TF96 transformer outputs of; *) HIGH mode **) LOW mode
(see summary of testing)
Tested condition: 1 kHz input signal, connected 6 ohm loads for F, SB, S, C channels.
Loudspeaker impedance (Ω) .................................. :
6 Ohms
—
Several loudspeaker systems ................................. :
Right and Left for Front,
Right and Left for Surround Back,
Right and Left for Surround,
Only one for Center.
Right and Left for Surround Back,
Right and Left for Surround,
Only one for Center.
P
Marking of loudspeaker terminals ........................... :
SPEAKERS (6 Ω ~ 8 Ω)
P
Click on the first or last page to see other AVR 370 (serv.man4) service manuals if exist.