Page 33 of 61 
Report No.: 215445 
 
 
TRF No. IEC60065K 
Temperature Rise dT of Part 
dT (K) 
Limit max 
dT (K) *)
Test Condition No. 
No. 14 
No. 22 
No. 18 
No. 26 
Transformer, TF91 coil 
35.0 
42.8 
26.5 
41.7 
85   **) 
Transformer, 
TF91 
core 
31.9 39.9 23.2 38.7 95 
Transformer, TF92 coil 
36.6 
46.4 
33.0 
45.4 
85   **) 
Transformer, 
TF92 
core 
33.0 41.8 29.6 40.8 95 
Transformer, TF95 coil 
62.3 
68.2 
59.5 
67.2 
85   **) 
Transformer, 
TF95 
core 
44.0 54.2 40.8 53.3 95 
Transformer, TF96 coil 
60.9 
68.5 
58.2 
67.5 
85   **) 
Transformer, 
TF96 
core 
52.5 61.9 48.7 60.9 95 
Line filter, LF91 coil 
28.5 
32.0 
25.2 
30.6 
60   **) 
Line filter, LF92 coil 
26.7 
30.6 
23.7 
29.3 
60   **) 
Line filter, LF93 coil 
25.1 
30.7 
22.0 
29.4 
60   **) 
PFC inductor, CLZ9Z148Z coil 
32.2 
37.1 
28.9 
36.1 
60   **) 
PFC 
inductor, 
CLZ9Z148Z 
core 
28.2 35.7 25.0 35.3 70 
Body 
of 
DB91 
53.8 46.4 51.2 45.3 - 
PWB 
near 
DB91 
29.2 30.9 26.7 29.4 95 
Body 
of 
Q910 
37.0 46.0 34.1 44.7 - 
PWB 
near 
Q910 
36.1 44.9 33.5 43.7 95 
Heat-sink 
of 
Q910 
35.1 43.7 32.3 42.4 - 
Body 
of 
C930 
29.6 34.4 26.6 33.1 105 
o
Body 
of 
connector, 
CN90 
25.1 32.3 22.1 31.5 - 
Body 
of 
connector, 
CN91 
24.5 29.9 21.7 28.6 - 
Body of connector, SW91 
27.9 
30.5 
26.2 
29.1 
Body of connector, SW92 
24.5 
34.1 
24.7 
32.9 
Heat-sink 
of 
D956 
47.8 61.8 44.3 60.6 - 
PWB 
near 
D956 
41.7 50.8 38.9 49.8 95 
Body 
of 
C966 
38.8 48.2 35.8 47.2 105 
o
Body 
of 
Q654 
55.2 44.9 53.2 46.5 - 
PWB 
near 
Q654 
37.4 32.6 35.2 32.8 95 
Body 
of 
C916 
17.3 20.7 14.5 19.5 85 
o
Main 
heat-sink 
44.3 41.3 42.3 42.9 - 
 
Page 34 of 61 
Report No.: 215445 
 
 
TRF No. IEC60065K 
Temperature Rise dT of Part  
(continued)
 
dT (K) 
Limit max 
dT (K) *)
Test Condition No. 
No. 14 
No. 22 
No. 18 
No. 26 
FAN body (installed in main heat-sink) 
18.1 
16.1 
15.0 
15.0 
FAN body (installed in back cover inside) 
16.8 
21.6 
14.0 
20.3 
PWB near wifi module 
32.5 
25.0 
20.3 
23.6 
70 
Body of wifi module 
27.3 
17.2 
14.1 
16.0 
Appliance 
inlet 
body 
10.0 12.9 7.7  11.6 60 
Main switch body (non-metallic) 
10.2 
12.5 
7.6 
11.3 
50 
Stand-by 
button 
(non-metallic) 
5.4 6.8 3.2 6.0 50 
Front 
cover 
(metallic) 
5.7 8.3 3.6 7.3 40 
Top cover above main transf.(metallic) 
15.1 
16.0 
12.2 
14.9 
40 
Top cover above Heat-sink (metallic) 26.7 27.0 23.9 26.3 40 
Ambient 23.0 
o
C 23.2 
o
C 25.6 
o
C 24.6 
o
C - 
 
 
 
 
 
 
*) Temperature rise limits for tropical climate is 10K less.  
**) Minus (-) 10 K applied for thermo-couple method for windings. 
Tested condition; 
Wall condition: 30 cm top and other sides 
USB port loaded output: 2.6 A loaded through USB port (2.6A is achievable MAX load continuously).  
 
 
 
 
Page 35 of 61 
Report No.: 215445 
 
 
TRF No. IEC60065K 
Temperature Rise dT of Part 
dT (K) 
Limit max 
dT (K) *)
Test Condition No. 
No. 11 
No. 19 
No. 15 
No. 23 
Transformer, TF91 coil 
27.7 
41.0 
33.3 
41.3 
85   **) 
Transformer, 
TF91 
core 
24.3 37.8 30.1 38.4 95 
Transformer, TF92 coil 
34.3 
44.7 
35.0 
44.9 
85   **) 
Transformer, 
TF92 
core 
30.8 40.0 31.3 40.2 95 
Transformer, TF95 coil 
60.1 
64.2 
59.9 
64.5 
85   **) 
Transformer, 
TF95 
core 
42.3 51.6 42.0 51.9 95 
Transformer, TF96 coil 
58.7 
64.1 
58.2 
64.4 
85   **) 
Transformer, 
TF96 
core 
50.5 58.0 48.5 58.5 95 
Line filter, LF91 coil 
28.8 
34.0 
30.0 
33.9 
60   **) 
Line filter, LF92 coil 
27.0 
31.6 
28.0 
31.7 
60   **) 
Line filter, LF93 coil 
25.3 
31.4 
25.8 
31.7 
60   **) 
PFC inductor, CLZ9Z148Z coil 
37.3 
41.4 
39.2 
41.9 
60   **) 
PFC 
inductor, 
CLZ9Z148Z 
core 
28.5 38.3 31.0 39.4 70 
Body 
of 
DB91 
65.4 55.2 66.3 56.9 - 
PWB 
near 
DB91 
32.3 32.5 33.0 32.7 95 
Body 
of 
Q910 
33.6 40.9 33.6 41.6 - 
PWB 
near 
Q910 
33.7 40.6 33.7 41.3 95 
Heat-sink 
of 
Q910 
32.1 38.9 32.0 39.6 - 
Body 
of 
C930 
29.3 34.1 29.5 34.1 105 
o
Body 
of 
connector, 
CN90 
23.6 30.9 24.9 31.7 - 
Body 
of 
connector, 
CN91 
24.4 29.8 24.9 30.0 - 
Body of connector, SW91 
31.0 
32.5 
31.7 
32.4 
Body of connector, SW92 
26.1 
32.9 
26.5 
33.0 
Heat-sink 
of 
D956 
46.1 59.7 46.2 59.8 - 
PWB 
near 
D956 
40.0 48.4 39.9 48.6 95 
Body 
of 
C966 
37.5 45.5 36.8 45.8 105 
o
Body 
of 
Q654 
54.6 46.6 55.5 47.6 - 
PWB 
near 
Q654 
36.4 33.0 37.4 33.7 95 
Body 
of 
C916 
15.9 19.2 16.0 19.5 85 
o
Main 
heat-sink 
43.5 43.3 44.5 44.1 - 
 
Page 36 of 61 
Report No.: 215445 
 
 
TRF No. IEC60065K 
Temperature Rise dT of Part (continued)
dT (K) 
Limit max 
dT (K) *)
Test Condition No. 
No. 11 
No. 19 
No. 15 
No. 23 
FAN body (installed in main heat-sink) 
16.5 
14.5 
16.4 
14.8 
FAN body (installed in back cover inside) 
15.4 
19.9 
15.6 
20.2 
PWB near wifi module 
21.7 
23.2 
21.2 
25.0 
70 
Body of wifi module 
15.9 
15.5 
15.9 
16.5 
Appliance 
inlet 
body 
8.5 11.1 8.7 11.3 60 
Main switch body (non-metallic) 
8.5 
10.7 
8.5 
11.0 
50 
Stand-by 
button 
(non-metallic) 
4.2 5.3 4.0 5.9 50 
Front 
cover 
(metallic) 
5.0 7.0 4.8 7.3 40 
Top cover above main transf.(metallic) 
12.8 
14.3 
13.1 
14.4 
40 
Top cover above Heat-sink (metallic) 25.4 26.7 25.9 27.2 40 
Ambient 24.0 
o
C 23.3 
o
C 22.6 
o
C 22.6 
o
C - 
 
 
 
 
 
 
*) Temperature rise limits for tropical climate is 10K less.  