Harman Kardon AVR 370 (serv.man4) EMC - CB Certificate ▷ View online
Page 37 of 61
Report No.: 215445
TRF No. IEC60065K
7.2
TABLE: softening temperature of thermoplastics
P
Temperature T of part
T - normal condi-
tions (
o
C)
T - fault conditions
(
o
C)
Min T softening
(
o
C)
AC connector (CN90)
32.3 (55.5
o
C)
(I/P=264 V,
ambient 23.2
ambient 23.2
o
C)
45.9 (67.8
o
C)
(I/P=264 V,
ambient 21.9
ambient 21.9
o
C)
> 200
(type, YW396 series)
(type, YW396 series)
AC connector (CN91)
30.0 (52.6
o
C)
(I/P=264 V,
ambient 22.6
ambient 22.6
o
C)
44.2 (66.1
o
C)
(I/P=264 V,
ambient 21.9
ambient 21.9
o
C)
> 200
(type, YW396 series)
(type, YW396 series)
Main switch connector (SW91)
32.5 (55.8
o
C)
(I/P=198 V,
ambient 23.3
ambient 23.3
o
C)
45.1 (67.0
o
C)
(I/P=264 V,
ambient 21.9
ambient 21.9
o
C)
> 200
(type, YW396 series)
(type, YW396 series)
Main switch connector (SW92)
34.1 (57.3
o
C)
(I/P=264 V,
ambient 23.2
ambient 23.2
o
C)
47.6 (69.5
o
C)
(I/P=264 V,
ambient 21.9
ambient 21.9
o
C)
> 200
(type, YW396 series)
(type, YW396 series)
Line filter (LF91)
34.0 (57.3
o
C)
(I/P=198 V,
ambient 23.3
ambient 23.3
o
C)
49.1 (71.0
o
C)
(I/P=264 V,
ambient 21.9
ambient 21.9
o
C)
> 180
(type, GP2156F(#))
(type, GP2156F(#))
> 180
(type, 1500GN-(k))
(type, 1500GN-(k))
> 170
(type, A 50H1 (r3)(f2))
Line filter (LF92)
31.7 (54.3
o
C)
(I/P=198 V,
ambient 22.6
ambient 22.6
o
C)
46.9 (68.8
o
C)
(I/P=264 V,
ambient 21.9
ambient 21.9
o
C)
> 180
(type, GP2156F(#))
(type, GP2156F(#))
> 180
(type, 1500GN-(k))
(type, 1500GN-(k))
> 170
(type, A 50H1 (r3)(f2))
Page 38 of 61
Report No.: 215445
TRF No. IEC60065K
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
(as received and after humidity/surge)
(as received and after humidity/surge)
Min 2.6
Min 2
Between parts separated by double or reinforced insulation
(as received and after humidity/surge)
(as received and after humidity/surge)
Min 5.2
Min 4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
(as received and after humidity/surge/fault condition tests)
(as received and after humidity/surge/fault condition tests)
1500 Vac
No
Between parts separated by double or reinforced insulation
(as received and after humidity/surge/fault condition tests)
(as received and after humidity/surge/fault condition tests)
3000 Vac
No
Tubing for TS91, TS92 lead wires
3000 Vac
No
Page 39 of 61
Report No.: 215445
TRF No. IEC60065K
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ............. : 198V or 264V
—
Frequency
(Hz) ........................................................ : 50Hz
—
Ambient
temperature
(
o
C) ...................................... : 19 - 23
o
C
—
No.
Component
Fault
Duration
of the test
Other results
(include description)
dT (K) / Component
dT (K)
Permitted
dT (K)
1. *),
#)
#)
D933
(A to C)
(A to C)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.08 A.
NCD. No hazard.
FI stabilized at 0.08 A.
NCD. No hazard.
N/A N/A
2. *),
#)
#)
C980
SC
10 min
Unit shut down immediately.
FI stabilized at 0.08 A.
NCD. No hazard.
FI stabilized at 0.08 A.
NCD. No hazard.
N/A N/A
3. *),
#)
#)
D922
(A to C)
(A to C)
SC 30
min
Normal
operated.
The operating mode changed to
LOW mode after 2 min 10 s.
FI stabilized at 1.46 A.
NCD. No hazard.
LOW mode after 2 min 10 s.
FI stabilized at 1.46 A.
NCD. No hazard.
N/A
N/A
4. *),
#)
#)
C932
SC
10 min
Unit shut down immediately.
FI stabilized at 0.08 A.
NCD. No hazard.
FI stabilized at 0.08 A.
NCD. No hazard.
N/A N/A
5. *),
#)
#)
D937
(A to C)
(A to C)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.10 A.
NCD. No hazard.
FI stabilized at 0.10 A.
NCD. No hazard.
N/A N/A
6. *),
#)
#)
C953
SC
10 min
Unit shut down immediately.
FI stabilized at 0.10 A.
NCD. No hazard.
FI stabilized at 0.10 A.
NCD. No hazard.
N/A N/A
7. *),
#)
#)
C955
SC
10 min
Unit shut down immediately.
FI stabilized at 0.08 A.
NCD. No hazard.
FI stabilized at 0.08 A.
NCD. No hazard.
N/A N/A
8. *),
#)
#)
D941
(A to C)
(A to C)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.06 A.
NCD. No hazard.
FI stabilized at 0.06 A.
NCD. No hazard.
N/A N/A
9. *),
#)
#)
C941
SC
20 min
Unit shut down immediately.
FI stabilized at 0.10 A.
NCD. No hazard.
FI stabilized at 0.10 A.
NCD. No hazard.
N/A N/A
10. *),
#)
#)
D943
(A to C)
(A to C)
SC
20 min
Unit shut down immediately.
FI stabilized at 0.09 A.
NCD. No hazard.
FI stabilized at 0.09 A.
NCD. No hazard.
N/A N/A
11. *),
#)
#)
C949
SC
20 min
Unit shut down immediately.
FI stabilized at 0.09 A.
NCD. No hazard.
FI stabilized at 0.09 A.
NCD. No hazard.
N/A N/A
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
*) Tested voltage 264 V
**) Tested voltage 198 V
Apparatus mode; #) HIGH mode ##) LOW mode
Page 40 of 61
Report No.: 215445
TRF No. IEC60065K
No.
Component
Fault
Duration
of the test
Other results
(include description)
dT (K) / Component
dT (K)
Permitted
dT (K)
12. *),
#)
#)
Q914
(E to C)
(E to C)
SC 30
min
Normal
operated.
The operating mode changed to
LOW mode after 2 min 20 s.
FI stabilized at 1.46 A.
NCD. No hazard.
LOW mode after 2 min 20 s.
FI stabilized at 1.46 A.
NCD. No hazard.
N/A N/A
13. *),
#)
#)
D921
(A to C)
(A to C)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.09 A.
NCD. No hazard.
FI stabilized at 0.09 A.
NCD. No hazard.
N/A N/A
14. *),
#)
#)
C944
SC
10 min
Unit shut down immediately.
FI changed between
0.08 A and 0.09 A periodically.
NCD. No hazard.
FI changed between
0.08 A and 0.09 A periodically.
NCD. No hazard.
N/A N/A
15. *),
#)
#)
C929
SC
10 min
Unit shut down immediately.
FI changed between
0.08 A and 0.09 A periodically.
NCD. No hazard.
FI changed between
0.08 A and 0.09 A periodically.
NCD. No hazard.
N/A N/A
16. *),
#)
#)
D954
(A to C)
(A to C)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.08 A.
NCD. No hazard.
FI stabilized at 0.08 A.
NCD. No hazard.
N/A N/A
17. *),
#)
#)
C942
SC
10 min
Unit shut down immediately.
FI stabilized at 0.08 A.
NCD. No hazard.
FI stabilized at 0.08 A.
NCD. No hazard.
N/A N/A
18. *),
#)
#)
C946
SC
50 min
Unit shut down immediately.
FI stabilized at 0.08 A.
NCD. No hazard.
FI stabilized at 0.08 A.
NCD. No hazard.
N/A N/A
19. *),
#)
#)
D956
(A to C)
(A to C)
SC
10 min
Unit shut down immediately.
FI stabilized at 0.08 A.
NCD. No hazard.
FI stabilized at 0.08 A.
NCD. No hazard.
N/A N/A
20. *),
#)
#)
C966
SC
10 min
Unit shut down immediately.
FI stabilized at 0.08 A.
NCD. No hazard.
FI stabilized at 0.08 A.
NCD. No hazard.
N/A N/A
21. *),
#)
#)
C969
SC
10 min
Unit shut down immediately.
FI stabilized at 0.08 A.
NCD. No hazard.
FI stabilized at 0.08 A.
NCD. No hazard.
N/A N/A
22. *),
#)
#)
PC96
(Pin1 to Pin2)
(Pin1 to Pin2)
SC
20 min
All speakers output off
immediately.
USB output voltage repeated
on/off.
FI changed between
0.18 A and 0.36 A periodically.
NCD. No hazard.
immediately.
USB output voltage repeated
on/off.
FI changed between
0.18 A and 0.36 A periodically.
NCD. No hazard.
N/A N/A
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
*) Tested voltage 264 V
**) Tested voltage 198 V
Apparatus mode; #) HIGH mode ##) LOW mode