Report No.: 163976
TRF No. IEC60065J
11.2
TABLE: summary of fault condition tests
P
Voltage (V) 0,9 or 1,1 times rated voltage ............. :
198V or 264V
—
Ambient
temperature
(
o
C) ...................................... :
22
o
C - 27
o
C
—
Monitored point:
Under fault conditions specified below
dT (K)
Permitted
dT (K)
1. *), ***), D114 (A to C), SC, 20 min;
Normal operated. FI down at 1.56A after 5 min and stabilised.
R104 opened. No hazard.
Normal operated. FI down at 1.56A after 5 min and stabilised.
R104 opened. No hazard.
N/A N/A
2. **), ****), D117 (A to C), SC, 10 min;
Signal output off immediately. FI stabilised at 0.55A, R104 and R107 opened.
No hazard.
Signal output off immediately. FI stabilised at 0.55A, R104 and R107 opened.
No hazard.
N/A N/A
3. *), ***), D991 (AC to +), SC, 10 min;
F901 opened immediately. FI stabilised at 0.013A, No hazard.
F901 opened immediately. FI stabilised at 0.013A, No hazard.
N/A N/A
4. **), ****), D991 (AC to -), SC, 10 min;
F901 opened immediately. FI stabilised at 0.008A. No hazard.
F901 opened immediately. FI stabilised at 0.008A. No hazard.
N/A N/A
5. *), ***), D701 (AC to +), SC, 20 min;
Signal output off immediately. FI stabilised at 0.48A. F110 and F111 opened.
No hazard.
Signal output off immediately. FI stabilised at 0.48A. F110 and F111 opened.
No hazard.
N/A N/A
6. **), ****), D701 (AC to -), SC, 10 min;
Normal operated. FI stabilised at 1.43A. F110 opened. No hazard.
Normal operated. FI stabilised at 1.43A. F110 opened. No hazard.
N/A N/A
7. *), ****), C129, SC, 20 min;
Signal and USB output and FL display off immediately. FI stabilised at 0.47A.
F110 and F111 opened. No hazard.
Signal and USB output and FL display off immediately. FI stabilised at 0.47A.
F110 and F111 opened. No hazard.
N/A N/A
8. *), ****), C929, SC, 10 min;
Signal output and FL display off immediately. FI stabilised at 0.98A.
R104 and R107 damaged. No hazard.
Signal output and FL display off immediately. FI stabilised at 0.98A.
R104 and R107 damaged. No hazard.
N/A N/A
9. *), ***), C916, SC, 10 min;
Unit shut down immediately. FI stabilised at 0.009A. NCD. No hazard.
Unit shut down immediately. FI stabilised at 0.009A. NCD. No hazard.
N/A N/A
10. **), ****), C915, SC, 10 min;
Unit shut down immediately. FI stabilised at 0.008A. NCD. No hazard.
Unit shut down immediately. FI stabilised at 0.008A. NCD. No hazard.
N/A N/A
11. **), ****), Q805 (C to E), SC, 10 min;
Unit shut down immediately. FI stabilised at 0.007A.
Q805, Q807, Q851, R811, R820 and R824 damaged. No hazard.
Unit shut down immediately. FI stabilised at 0.007A.
Q805, Q807, Q851, R811, R820 and R824 damaged. No hazard.
N/A N/A
12. *), ***), Q805 (B to C), SC, 10 min;
Unit shut down immediately. FI stabilised at 0.009A. NCD. No hazard.
Unit shut down immediately. FI stabilised at 0.009A. NCD. No hazard.
N/A N/A
13. **), ****), Q807 (C to E), SC, 10 min;
Unit shut down immediately. FI stabilised at 0.006A.
Q805, R811 and R820 damaged. No hazard.
Unit shut down immediately. FI stabilised at 0.006A.
Q805, R811 and R820 damaged. No hazard.
N/A N/A
*) Tested voltage 264V
**) Tested voltage 198V
Tested at, ***) HIGH mode, ****) LOW mode of the main transformer S1A or S1B output.
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
Page 38 of 45
Report No.: 163976
TRF No. IEC60065J
Monitored point:
Under fault conditions specified below- continued
dT (K)
Permitted
dT (K)
14. *), ***), Q807 (B to C), SC, 10 min;
Unit shut down immediately. FI stabilised at 0.006A. Q805 damaged.
No hazard.
Unit shut down immediately. FI stabilised at 0.006A. Q805 damaged.
No hazard.
N/A N/A
15. *), ****), C809, SC, 20 min;
SBR signal output voltage dropped to 2.48V. FI stabilised at 1.45A.
R823 damaged. No hazard.
SBR signal output voltage dropped to 2.48V. FI stabilised at 1.45A.
R823 damaged. No hazard.
N/A N/A
16. *), ****), D901 (A to C), SC, 1 hr;
Unit shut down after 45 min. FI stabilised at 0.021A.
Sub transformer primary winding heated up to 105.8K and stabilised.
Dielectric strength test O.K. No hazard.
Unit shut down after 45 min. FI stabilised at 0.021A.
Sub transformer primary winding heated up to 105.8K and stabilised.
Dielectric strength test O.K. No hazard.
Sub transf.
105.8
Sub transf.
150
17. *), ****), C906, SC, 1 hr;
Unit shut down immediately. FI stabilised at 0.020A.
Sub transformer primary winding heated up to 108.9K and stabilised.
Dielectric strength test O.K. No hazard.
Unit shut down immediately. FI stabilised at 0.020A.
Sub transformer primary winding heated up to 108.9K and stabilised.
Dielectric strength test O.K. No hazard.
Sub transf.
108.9
Sub transf.
150
18. *), ****), Speaker output (Center- ch.), SC, 10 min;
Unit shut down immediately. FI stabilised at 0.008A. NCD. No hazard.
Unit shut down immediately. FI stabilised at 0.008A. NCD. No hazard.
N/A N/A
19. *), ****), USB output, SC, 10 min;
USB output off immediately. FI stabilised at 1.55A. NCD. No hazard.
USB output off immediately. FI stabilised at 1.55A. NCD. No hazard.
N/A N/A
20.*), ****), Pmax operated (Maximum non-clipped output signal);
1st.)
Main transformer primary winding heated up to 155.9K and thermal fuse
opened after 18 min. FI stabilised at 0.008A. Dielectric strength test O.K.
No hazard.
2nd.)
Main transformer primary winding heated up to 153.4K and thermal fuse
opened after 26 min. FI stabilised at 0.008A. Dielectric strength test O.K.
No hazard.
3rd.)
Main transformer primary winding heated up to 156.0K and thermal fuse
opened after 34 min. FI stabilised at 0.008A. Dielectric strength test O.K.
No hazard.
1st.)
Main transformer primary winding heated up to 155.9K and thermal fuse
opened after 18 min. FI stabilised at 0.008A. Dielectric strength test O.K.
No hazard.
2nd.)
Main transformer primary winding heated up to 153.4K and thermal fuse
opened after 26 min. FI stabilised at 0.008A. Dielectric strength test O.K.
No hazard.
3rd.)
Main transformer primary winding heated up to 156.0K and thermal fuse
opened after 34 min. FI stabilised at 0.008A. Dielectric strength test O.K.
No hazard.
Main transf.
See note #)
See note #)
Main transf.
See note #)
See note #)
Main transf.
See note #)
See note #)
Main transf.
150
Main transf.
150
Main transf.
150
*) Tested voltage 264V
**) Tested voltage 198V
Tested at, ***) HIGH mode, ****) LOW mode of the main transformer S1A or S1B output.
#) The temperature rise of the sub transformer was measured to >150K (exceeding allowable limit), but
transformer passed the testes described in sub clause 11.2.5 (tests repeated three times).
transformer passed the testes described in sub clause 11.2.5 (tests repeated three times).
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
Page 39 of 45
Report No.: 163976
TRF No. IEC60065J
Monitored point:
Under fault conditions specified below- continued
dT (K)
Permitted
dT (K)
21. *), ****), Cover opening, Blocked, 4 hr;
Normal operated. FI stabilised at 1.56A. NCD. Dielectric strength test O.K.
No hazard.
Normal operated. FI stabilised at 1.56A. NCD. Dielectric strength test O.K.
No hazard.
See # in the next page
for measured highest
temperature.
22. *), ****), Fan stalled (installed in back cover), 5 hr;
Normal operated. FI stabilised at 1.56A. NCD, Dielectric strength test O.K.
No hazard.
Normal operated. FI stabilised at 1.56A. NCD, Dielectric strength test O.K.
No hazard.
See ## in the next page for
measured temperature.
23. *), ****), Fan stalled (installed in main heat-sink), 4 hr;
Normal operated. FI stabilised at 1.56A. NCD, Dielectric strength test O.K.
No hazard.
Normal operated. FI stabilised at 1.56A. NCD, Dielectric strength test O.K.
No hazard.
See ### in the next page
for measured temperature.
*) Tested voltage 264V
**) Tested voltage 198V
Tested at, ***) HIGH mode, ****) LOW mode of the main transformer S1A or S1B output.
Note- SC: Short-circuit, NCD: No component damage, FI: Fault Input Current
Page 40 of 45
Report No.: 163976
TRF No. IEC60065J
11.2
TABLE: temperature rise measurements
P
Monitored point:
#)
dT (K) at
264V/50Hz
##)
dT (K) at
264V/50Hz
###)
dT (K) at
264V/5Hz
Permitted
dT (K)
Sub transformer core
45.2
30.9
22.0
150
Main transformer core
67.0 69.8
61.4 150
PWB near D991
62.1
71.0
42.8
110
PWB near D701
54.0 49.4
47.2 110
PWB near Q803
60.1
56.6
56.9
110
PWB near IC84
53.5
49.6
59.6
110
CN91 AC connector
37.4
25.3
19.8
-
CN92 AC connector
41.8
28.7
24.3
-
Appliance inlet
44.3
32.2
16.1
65
Front panel (non-metallic)
17.7
14.5
15.2
65
Front panel (metallic)
13.5
11.2
8.4
65
Stand-by button (non-metallic)
11.0
8.9
6.8
65
Mains switch (rear side)
22.3
15.6
11.9
65
Top cover above main transformer (metallic)
39.8
34.6
12.5
65
Top cover above main heat-sink (metallic)
44.6
35.7
42.8
65
Ambient 23.6°C
23.2°C
23.4°C
-
*) Based on softening temperature test (see table 7.2).
Winding temperature rise
measurements
measurements
#)
264V
50Hz
50Hz
##)
264V
50Hz
50Hz
###)
264V
60Hz
60Hz
Ambient temperature t1 (
o
C) :
20.0 20.0 20.0
Ambient temperature t2 (
o
C) :
23.6 23.2 23.4
Temperature rise dT of winding:
R
1
(Ω)
R
2
(Ω)
dT (K)
Permitted
dT (K)
Insulation
class
#) Main transf. primary winding (264V, 50Hz)
2.471 3.38 90.0 150
B
#) Sub transf. primary winding (264V, 50Hz)
3734 4601 55.5 150
E
##) Main transf. primary winding (264V, 50Hz)
2.471 3.370 89.4 150
B
##) Sub transf. primary winding (264V, 50Hz)
3734 4378 40.7 150
E
###) Main transf. primary winding (264V, 50Hz)
2.471 3.37 89.2 150
B
###) Sub transf. primary winding (264V, 50Hz)
3734 4243 31.2 150
E