Harman Kardon AVR 365 (serv.man2) EMC - CB Certificate ▷ View online
Page 33 of 45
Report No.: 163976
TRF No. IEC60065J
Measured at 1/8 of maximum non-clipped output with loaded 5V/0.5A through USB terminals; 50Hz
Un (V)
In (A)
Pn (W)
Pout (W)
198
*) 2.01 / **) 1.55
#) 1.43
*) 315.0 / **) 240.2
#) 220.6
2 x 5.94 W (F)
1 x 6.25 W (C)
2 x 6.13 W (S)
2 x 6.16 W (S/B)
1 x 6.25 W (C)
2 x 6.13 W (S)
2 x 6.16 W (S/B)
220
*) 2.07 / **) 1.58
#) 1.46
*) 355.4 / **) 267.1
#) 247.1
240
*) 2.12 / **) 1.60
#) 1.51
*) 394.6 / **) 293.1
#) 275.8
264
*) 2.25 / **) 1.62
#) 1.56
*) 456.1 / **) 325.9
#) 309.8
Measured at 1/8 of maximum non-clipped output with loaded 5V/0.5A through USB terminals; 60Hz
Un (V)
In (A)
Pn (W)
Pout (W)
198
*) 2.00 / **) 1.54
#) 1.42
*) 313.3 / **) 239.5
#) 218.6
2 x 5.94 W (F)
1 x 6.25 W (C)
2 x 6.13 W (S)
2 x 6.16 W (S/B)
1 x 6.25 W (C)
2 x 6.13 W (S)
2 x 6.16 W (S/B)
220
*) 2.05 / **) 1.57
#) 1.48
*) 352.9 / **) 266.6
#) 245.3
240
*) 2.10 / **) 1.59
#) 1.50
*) 389.8 / **) 292.1
#) 271.6
264
*) 2.22 / **) 1.61
#) 1.52
*) 453.5 / **) 323.8
#) 305.2
Measured at, *) HIGH (S1A) mode **) LOW (S1B) mode
of the main transformer S1A or S1B outputs (selected by RY21).
of the main transformer S1A or S1B outputs (selected by RY21).
The values followed #) in table above are measured “A” or “W” values, when replaced the input signal from
1 kHz sign wave to pink noise.
1 kHz sign wave to pink noise.
The input tests were conducted at 1 kHz sign wave input signal with 8 ohm loads for all channels connected
condition, and then replaced the input signal to pink noise for normal heating and all fault condition tests,
except for Pmax operating (Pmax operating in the fault condition tests were performed with 1 kHz sign wave
input signal for monitoring the signal outputs).
condition, and then replaced the input signal to pink noise for normal heating and all fault condition tests,
except for Pmax operating (Pmax operating in the fault condition tests were performed with 1 kHz sign wave
input signal for monitoring the signal outputs).
Loudspeaker impedance (Ω) ..............
8 Ohm
—
Several loudspeaker systems
Right and Left for Front,
Right and Left for Surround Back,
Right and Left for Surround,
Only one for Center.
Right and Left for Surround Back,
Right and Left for Surround,
Only one for Center.
P
Marking of loudspeaker terminals
SPEAKERS (8Ω):
FRONT RIGHT, FRONT LEFT,
SBR / ZONE2 R FRONT HEIGHT R,
SBL / ZONE2 L FRONT HEIGHT L,
SURR. RIGHT, SURR. LEFT, CENTER.
FRONT RIGHT, FRONT LEFT,
SBR / ZONE2 R FRONT HEIGHT R,
SBL / ZONE2 L FRONT HEIGHT L,
SURR. RIGHT, SURR. LEFT, CENTER.
P
Page 34 of 45
Report No.: 163976
TRF No. IEC60065J
Monitored point:
dT (K) at
198V/50Hz
dT (K) at
264V/50Hz
dT (K) at
198V/60Hz
dT (K) at
264V 60Hz
Permitted
dT (K) #)
Sub transformer core
31.1
34.0
29.5
32.4
85
Main transformer core
62.6 64.6 61.5 63.1 95
PWB near D991
53.3
57.8
55.4
57.7
95
Heat-sink of D991
75.4
79.5
77.6
80.4
-
PWB near D701
42.4 41.6 41.1 41.6 95
Heat-sink of D701
46.0
43.1
44.7
43.2
-
E Capacitor, C916 body
22.2
21.6
21.3
21.7
85
C
PWB near Q803
50.4
51.9
49.4
52.4
95
E Capacitor, C129 body
31.4
32.5
31.1
32.8
85
C
PWB near IC84
40.0
43.8
39.4
44.2
95
FAN body (installed in back cover inside)
27.0
26.1
25.7
25.6
-
FAN body (installed in main heat-sink)
16.2
14.0
15.4
14.4
-
CN91 AC connector
28.8
28.2
28.3
27.8
-
CN92 AC connector
31.8
32.7
31.6
32.3
-
Main heat-sink
51.1
53.2
51.2
53.6
-
Appliance inlet
24.2
15.0
22.6
14.7
60
Front panel (non-metallic) 10.6
12.1
10.3
12.4
60
Front panel (metallic)
9.5 7.9 9.0 8.4 40
Stand-by button (non-metallic)
7.4
5.9
5.2
6.4
50
Mains switch (rear side)
15.0
14.9
15.2
14.6
50
Top cover above main transformer (metallic)
23.8
26.0
24.8
26.6
40
Top cover above main heat-sink (metallic)
28.7
27.4
27.5
27.8
40 *)
Top cover above main heat-sink (metallic)
31.3
33.2
29.0
33.7
65 **), ***)
Ambient 23.6°C
22.7°C
22.7°C
22.2°C
-
*) Measured highest temperature at top cover surface within area 150 mm distance from the control knobs
**) Measured highest temperature at top cover surface over 150 mm distance from the control knobs.
***) Hot surface symbol (IEC 60417-5041) applied on top cover surface.
#) Temperature rise limits for tropical climate is 10K less. Comply
Page 35 of 45
Report No.: 163976
TRF No. IEC60065J
Winding temperature rise
measurements
measurements
198V
50Hz
50Hz
264V
50Hz
50Hz
198V
60Hz
60Hz
264V
60Hz
60Hz
—
Ambient temperature t1 (
o
C) :
20.0 20.0 20.0 20.0
—
Ambient temperature t2 (
o
C) :
23.6 22.7 22.7 22.2
—
Temperature rise dT of winding:
R
1
(Ω)
R
2
(Ω)
dT (K)
Permitted
dT (K)
Insulation
class *)
Main transf. primary winding (264V, 50Hz)
2.471
3.32
84.7
95
B
Sub transf. primary winding (264V, 50Hz)
3734
4433
44.9
85
E
Main transf. primary winding (198V, 50Hz)
2.471
3.31
82.8
95
B
Sub transf. primary winding (198V, 50Hz)
3734
4369
39.7
85
E
Main transf. primary winding (264V, 60Hz)
2.471
3.30
83.2
95
B
Sub transf. primary winding (264V, 60Hz)
3734
4373
41.4
85
E
Main transf. primary winding (198V, 60Hz)
2.471
3.21
73.4
95
B
Sub transf. primary winding (198V, 60Hz)
3734
4208
29.6
85
E
*) Temperature rise limits for tropical climate is 10K less. Comply
Page 36 of 45
Report No.: 163976
TRF No. IEC60065J
7.2
TABLE: softening temperature of thermoplastics
P
Temperature T of part
T – normal con-
ditions (
o
C)
T – fault condi-
tions (
o
C)
Min T softening
(
o
C)
AC connector (CN91)
28.8 (52.4 °C)
(I/P=198V,
ambient 23.6 °C)
(I/P=198V,
ambient 23.6 °C)
37.4 (61.0 °C)
(I/P=264V,
ambient 23.6 °C)
(I/P=264V,
ambient 23.6 °C)
> 200
(type, YW396 series)
AC connector (CN92)
31.8 (55.4 °C)
(I/P=198V,
ambient 23.6 °C)
(I/P=198V,
ambient 23.6 °C)
41.8 (65.4 °C)
(I/P=264V,
ambient 23.6 °C)
(I/P=264V,
ambient 23.6 °C)
> 200
(type, YW396 series)
10.3
TABLE: insulation resistance measurements
P
Insulation resistance R between:
R (MΩ)
Required R (MΩ)
Between mains poles (primary fuse disconnected)
Min. 100
Min 2
Between parts separated by double or reinforced insulation
Min. 100
Min 4
Between mains poles (primary fuse disconnected)
after humidity test
after humidity test
Min. 6
Min 2
Between parts separated by double or reinforced insulation
after humidity test
after humidity test
Min. 17
Min 4
10.3
TABLE: electric strength measurements
P
Test voltage applied between:
Test voltage (V)
Breakdown
Mains poles (primary fuse disconnected)
1500 Vac
No
Between parts separated by double or reinforced insulation
3000 Vac
No
\Between mains poles (primary fuse disconnected)
after humidity test
after humidity test
1500 Vac
No
Between parts separated by double or reinforced insulation
after humidity test
after humidity test
3000 Vac
No
Between mains poles (primary fuse disconnected)
after components abnormal operated test
after components abnormal operated test
1500 Vac
No
Between parts separated by double or reinforced insulation
after components abnormal operated test
after components abnormal operated test
3000 Vac
No