Harman Kardon AVR 360 EMC - CB Certificate ▷ View online
- Page 6 of 10-
Report
No.
129950
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065_I
Annex ZA
Cont.
Cont.
P
GROUP DIFFERENCES FOR AMENDMENT 1
COMMON MODIFICATIONS
COMMON MODIFICATIONS
N/A
5.1 i)
in EN 60065:2002
Replace the note by:
NOTE For RATED POWER CONSUMPTION measurements of TVs reference is
made to EN 62087. Measurements are done in the ON (play) operating mode.
Replace the note by:
NOTE For RATED POWER CONSUMPTION measurements of TVs reference is
made to EN 62087. Measurements are done in the ON (play) operating mode.
N/A
5.4.1
Add the following indent:
za) A warning that excessive sound pressure from earphones and headphones
can cause hearing loss.
za) A warning that excessive sound pressure from earphones and headphones
can cause hearing loss.
N/A
6.1
6.1
6.1
in EN 60065:2002
Replace the subclause by:
Ionizing radiation
Equipment that might produce ionizing radiation is checked by measuring the amount
of radiation.
The amount of radiation is determined by means of a radiation monitor of the ionizing
chamber type with an effective area of 1 000 mm2 or by measuring equipment of other
types giving equivalent results.
Measurements are made with the equipment on test operating at the most
unfavourable supply voltage (see 4.2) and with operator controls and service controls
adjusted so as to give maximum radiation whilst maintaining the equipment operative
for normal use.
Internal preset controls not intended to be adjusted during the lifetime of the equipment
are not considered to be service controls.
At any point 100 mm from the surface of the operator access area, the dose-rate shall
not exceed 1
Replace the subclause by:
Ionizing radiation
Equipment that might produce ionizing radiation is checked by measuring the amount
of radiation.
The amount of radiation is determined by means of a radiation monitor of the ionizing
chamber type with an effective area of 1 000 mm2 or by measuring equipment of other
types giving equivalent results.
Measurements are made with the equipment on test operating at the most
unfavourable supply voltage (see 4.2) and with operator controls and service controls
adjusted so as to give maximum radiation whilst maintaining the equipment operative
for normal use.
Internal preset controls not intended to be adjusted during the lifetime of the equipment
are not considered to be service controls.
At any point 100 mm from the surface of the operator access area, the dose-rate shall
not exceed 1
μSv/h (0,1 mR/h) (see Note). Account shall be taken of the background
level.
NOTE These values appear in Directive 96/29/Euratom.
NOTE These values appear in Directive 96/29/Euratom.
N/A
- Page 7 of 10-
Report
No.
129950
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065_I
Bibliogra
phy in
EN
60065:20
02
phy in
EN
60065:20
02
Replace the paragraph related to prEN 50332-2 by:
EN 50332-2:2003, Sound system equipment: Headphones and earphones
associated with portable audio equipment - Maximum sound pressure level
measurement methodology and limit considerations - Part 2: Matching of
sets with headphones if either or both are offered separately EN
60065:2002/A1:2006 - 4 -
EN 50332-2:2003, Sound system equipment: Headphones and earphones
associated with portable audio equipment - Maximum sound pressure level
measurement methodology and limit considerations - Part 2: Matching of
sets with headphones if either or both are offered separately EN
60065:2002/A1:2006 - 4 -
N/A
Bibliogra
phy in IEC
60065:200
1/A1:2005
phy in IEC
60065:200
1/A1:2005
Add the following notes for the standards indicated:
IEC 60598-2-9 NOTE Harmonized as EN 60598-2-9:1989 + A1:1994
(not modified).
IEC 60598-2-17 NOTE Harmonized as EN 60598-2-17:1989 + A2:1991
(not modified).
IEC 60598-2-9 NOTE Harmonized as EN 60598-2-9:1989 + A1:1994
(not modified).
IEC 60598-2-17 NOTE Harmonized as EN 60598-2-17:1989 + A2:1991
(not modified).
N/A
ZB
ANNEX ZB TO EN 60065, SPECIAL NATIONAL CONDITIONS (EN)
2.6.1
DK: The following is added:
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Justification: Heavy Current Regulations, Section
107.
Certain types of CLASS I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Justification: Heavy Current Regulations, Section
107.
Class II apparatus
N/A
13.3.1
NO: To the second paragraph the following is
added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
added:
In Norway, due to the IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230 V in case of a single earth fault.
Justification: Based on a use in Norway of an IT
power distribution system where the neutral is not
provided.
Noted
P
- Page 8 of 10-
Report
No.
129950
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065_I
15.1.1
DK: To the first paragraph the following is added:
In Denmark, supply cords of single phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with
the Heavy Current Regulations Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for provided power to
CLASS II apparatus with a rated current of 2.5 A
shall have the following dimensions:
In Denmark, supply cords of single phase
appliances having a rated current not exceeding 13
A shall be provided with a plug according to the
Heavy Current Regulations Section 107-2-D1.
Appliances of CLASS I provided with socket-outlets
with earth contact or which are intended to be used
in locations where protection against indirect
contact is required according to the wiring rules
shall be provided with a plug in accordance with
the Heavy Current Regulations Section 107-2-D1
standard sheet DK 2-1a.
To the second paragraph the following is added:
Socket outlets intended for provided power to
CLASS II apparatus with a rated current of 2.5 A
shall have the following dimensions:
Dimensions in mm
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket-
outlets. Shutters are not required.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulations,
Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-
5a or DK 1-7a.
Justification
Other dimensions shall be in compliance with the
Heavy Current Regulations, Section 107-2-D1,
Standard Sheet DKA 1-3 for portable socket-
outlets. Shutters are not required.
To the third paragraph the following is added:
Mains socket-outlets with earthing contact shall be
in compliance with the Heavy Current Regulations,
Section 107-2-D1, Standard Sheet DK 1-3a, DK 1-
5a or DK 1-7a.
Justification
:
Heavy Current Regulations, Section 107
Class II socket-outlet provided.
P
15.1.1
IE: Apparatus which is fitted with a flexible cable or
cord shall be provided with a 13 A plug in
accordance with Statutory Instrument 525:97, “13 A
Plugs and Conversion Adapters for Domestic Use
Regulations:1997.
Justification:
cord shall be provided with a 13 A plug in
accordance with Statutory Instrument 525:97, “13 A
Plugs and Conversion Adapters for Domestic Use
Regulations:1997.
Justification:
SI 525: 1997
When marketing in Ireland,
the apparatus must be supplied
with a cord and plug acceptable
in Ireland.
the apparatus must be supplied
with a cord and plug acceptable
in Ireland.
N/A
- Page 9 of 10-
Report
No.
129950
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065_I
15.1.1
Cont.
Cont.
NO: Mains socket-outlets mounted on CLASS II
apparatus shall comply with the specifications
given in CEE Publ. 7 as fas as a Applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for electronic
apparatus shall comply with the enclosed Standard
Sheet I.
apparatus shall comply with the specifications
given in CEE Publ. 7 as fas as a Applicable, with
the following amendments:
§ 8 Dimensions
a 2.5 A 250 V two-pole socket-outlets for electronic
apparatus shall comply with the enclosed Standard
Sheet I.
§ 24 Mechanical strength
A 2,5 A 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall
be tested
Justification:
A 2,5 A 250 V socket-outlets for CLASS II
electronic apparatus are tested as specified in
12.1.3 of EN 60065. Also the protecting rim shall
be tested
Justification:
Act of 24 May 1929 relating to
supervision of electrical installation (TEA 1929/FEL
1998).
1998).
Class II socket-outlet provided.
P
15.1.1
UK: Apparatus which is fitted with a flexible cable
or cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ”standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by
those Regulations.
NOTE ”Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.
Justification
or cord and is designed to be connected to a mains
socket conforming to BS 1363 by means of that
flexible cable or cord and plug shall be fitted with
a ”standard plug” in accordance with Statutory
Instrument 1768: 1994: The Plugs and Sockets etc.
(Safety) Regulations 1994, unless exempted by
those Regulations.
NOTE ”Standard plug” is defined in SI 1768:1994
and essentially means an approved plug
conforming to BS 1363 or an approved conversion
plug.
Justification
: SI 1768: 1994
Approved cord-set provided.
See appended table, list of
critical components.
See appended table, list of
critical components.
P
Click on the first or last page to see other AVR 360 service manuals if exist.