Report
No.
129950
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065_I
6.1
Replace the entire subclause by:
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
conditions.
Compliance is checked by measurement under the
following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND, by
any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
NOTE Soldered joints and paint lockings are
examples of adequate locking.
The amount of ionizing radiation is regulated by
European Council Directive 96/29/Euratom of 13
May 1996. This directive requires that at any point
10 cm from the outer surface of the apparatus, the
dose-rate shall not exceed 1µSv/h (0.1 Mr/h) taking
account of the background level.
Moreover, the measurement shall be made under
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is maintained
for 1 h, at the end of which the measurement is
made.
A picture is considered to be intelligible if the
following conditions are met:
- a scanning amplitude of at least 70% of the usable
screen width;
- a minimum luminance of 50 cd/m² with locked
blank raster provided by a test generator;
- a horizontal resolution corresponding to at least 1.5
MHz in the centre, with a similar vertical
degradation;
- not more than over flashover per 5 min.
Apparatus including a potential source of ionizing
radiation shall be so constructed that personal
protection against ionizing radiation is provided
under normal operating conditions and under fault
conditions.
Compliance is checked by measurement under the
following conditions:
In addition to the normal operating conditions, all
controls adjustable from the outside BY HAND, by
any object such as a tool or a coin, and those
internal adjustments or pre-sets which are not
locked in a reliable manner, are adjusted so as to
give maximum radiation whilst maintaining an
intelligible picture for 1 h, at the end of which the
measurement is made.
NOTE Soldered joints and paint lockings are
examples of adequate locking.
The amount of ionizing radiation is regulated by
European Council Directive 96/29/Euratom of 13
May 1996. This directive requires that at any point
10 cm from the outer surface of the apparatus, the
dose-rate shall not exceed 1µSv/h (0.1 Mr/h) taking
account of the background level.
Moreover, the measurement shall be made under
fault conditions causing an increase of the high-
voltage, provided an intelligible picture is maintained
for 1 h, at the end of which the measurement is
made.
A picture is considered to be intelligible if the
following conditions are met:
- a scanning amplitude of at least 70% of the usable
screen width;
- a minimum luminance of 50 cd/m² with locked
blank raster provided by a test generator;
- a horizontal resolution corresponding to at least 1.5
MHz in the centre, with a similar vertical
degradation;
- not more than over flashover per 5 min.
No ionizing radiation in the
equipment
equipment
N/A
13.3.1
Delete note 4.
Deleted
N/A
14
Delete note 4 and note 5.
Deleted
N/A
15.1.1
Delete notes 1 and 2.
Deleted
N/A
15.2
Delete note 2.
Deleted
N/A
16.1
Delete note 1.
Deleted
N/A
16.2
Delete the note.
Deleted
N/A
20
Delete note 2.
Deleted
N/A
- Page 3 of 10-
Report
No.
129950
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065_I
Annex B
Replace note 1 by:
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
In the CENELEC countries listed in IEC 62151,
special national conditions apply.
No TNV circuits.
N/A
Annex G
Delete the note.
Deleted
N/A
Annex J.2 Delete the notes of Table J.1.
Deleted
N/A
Annex N
Add after the introduction:
For ROUTINE TEST reference is made to EN
50333.
For ROUTINE TEST reference is made to EN
50333.
Considered.
P
Bibliograp
hy
hy
Add the following standards:
EN 60332-1: 2000, Sound system equipment: Headphones and earphones
associated with portable audio equipment –
EN 60332-1: 2000, Sound system equipment: Headphones and earphones
associated with portable audio equipment –
Maximum sound pressure level measurement methodology and limit
considerations – Part 1: General method for”one package equipment”.
PrEN 50332-2 (uder consideration), Sound system equipment: Headphones and
earphones associated with portable
considerations – Part 1: General method for”one package equipment”.
PrEN 50332-2 (uder consideration), Sound system equipment: Headphones and
earphones associated with portable
audio equipment – Maximum sound pressure level measurement methodology and
limit considerations – Part 2:
limit considerations – Part 2:
Guidelines to associate sets with headphones coming from different manufacturers.
Add the following notes for the standards indicated:
IEC 60130
NOTE Parts 9 and 17: 1998 are harmonized as Ens (not
modified).
IEC 60169
IEC 60169
NOTE Partly harmonized in the EN 60169/HD 134 series (not
modified).
IEC 60173
IEC 60173
NOTE Harmonized as HD 27 S1: 1978 (not modified).
IEC 60335-2-56
NOTE Harmonized as EN 60335-2-56: 1997 (not
modified).
IEC 60335-2-82
IEC 60335-2-82
NOTE Harmonized as EN 60335-2-82: 2000 (not
modified).
IEC 60695
IEC 60695
NOTE Harmonized as EN 60695 series (not modified).
IEC 61040
NOTE Harmonized as EN 61040: 1992 (not modified).
IEC 61558-2-1 NOTE Harmonized as EN 61558-2-1: 1997 (not modified).
IEC 61558-2-4 NOTE Harmonized as EN 61558-2-4: 1997 (not modified).
IEC 61558-2-6 NOTE Harmonized as EN 61558-2-6: 1997 (not modified).
IEC 61558-2-4 NOTE Harmonized as EN 61558-2-4: 1997 (not modified).
IEC 61558-2-6 NOTE Harmonized as EN 61558-2-6: 1997 (not modified).
P
- Page 4 of 10-
Report
No.
129950
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065_I
Annex ZA
(normative)
Other international publications quoted in this standard with the references
of the relevant European publications
This European Standard incorporates by dated or undated reference, provisions
from other publications. These normative references are cited at the appropriate
places in the text and the publications are listed hereafter. For dated references,
subsequent amendments to or revisions of any of these publications apply to this
European Standard only when incorporated in it by amendment or revision. For
undated references the latest edition of the publication referred to applies (including
amendments).
NOTE When an international standard has been modified by common modification,
indicated by (mod), the relevant EN/HD applies.
of the relevant European publications
This European Standard incorporates by dated or undated reference, provisions
from other publications. These normative references are cited at the appropriate
places in the text and the publications are listed hereafter. For dated references,
subsequent amendments to or revisions of any of these publications apply to this
European Standard only when incorporated in it by amendment or revision. For
undated references the latest edition of the publication referred to applies (including
amendments).
NOTE When an international standard has been modified by common modification,
indicated by (mod), the relevant EN/HD applies.
P
- Page 5 of 10-
Report
No.
129950
ATTACHMENT 3
Clause
Requirement + Test
Result - Remark
Verdict
TRF No. IEC60065_I
Annex ZA
Cont.
P