TABLE: list of critical components and materials
P
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference
Main
transformer
Bobbin Mtl.
Thermal fuse
transformer
Bobbin Mtl.
Thermal fuse
Seoul Electronics
& Telecom Co Ltd.
Wintech Polymer
Therm-O-Disc.
& Telecom Co Ltd.
Wintech Polymer
Therm-O-Disc.
KLT5W027ZE
CLT5W027ZE
CN9030
E4A51167C
CLT5W027ZE
CN9030
E4A51167C
230V, Class B
PET, V-0, 155
PET, V-0, 155
°C
10A/250V, 167
°C
IEC60065
clause 14.3
UL94
IEC60691
clause 14.3
UL94
IEC60691
1.)
UL, E213445
VDE
UL, E213445
VDE
Sub
transformer
Bobbin Mtl.
Thermal fuse
transformer
Bobbin Mtl.
Thermal fuse
Seoul Electronics
& Telecom Co Ltd.
LG Chemical Ltd..
Anzen Dengu Co
& Telecom Co Ltd.
LG Chemical Ltd..
Anzen Dengu Co
KLT5J038ZE
CLT5J038ZE
GP2306F(#)
K11
CLT5J038ZE
GP2306F(#)
K11
230V Class E
PBT, V-0, 140°C
PBT, V-0, 140°C
1A/250V, 115°C
IEC60065
clause 14.3
UL94
IEC60691
clause 14.3
UL94
IEC60691
1.)
UL E67171
VDE
UL E67171
VDE
Mains Cord Set
(For CENELEC)
(For CENELEC)
Volex (Asia) Pte Ltd M3204
H05VV-F
VAC17S
VAC17S
10/16A, 250V
0.75mm
0.75mm
2
x2
10A/250V
IEC60884-1
IEC60227
IEC60320
IEC60227
IEC60320
VDE
alt.
HWAJIN KDK Co.
KKP-4819D
H05VV-F
KKS-16A
H05VV-F
KKS-16A
10/16A, 250V
0.75mm
0.75mm
2
x2
10A/250V
IEC60884-1
IEC60227
IEC60320
IEC60227
IEC60320
VDE
Mains Cord Set
(For UK and
Singapore)
(For UK and
Singapore)
Volex (Asia) Pte Ltd MP5004
MP5004A
H05VV-F
VAC17S
H05VV-F
VAC17S
13A/250V
0.75mm
0.75mm
2
x2
10A/250V
BS1363
SS145
BS6500
IEC60320
SS145
BS6500
IEC60320
ASTA, PSB
ASTA, PSB
ASTA
VDE
ASTA, PSB
ASTA
VDE
Mains Cord Set
(For UK)
(For UK)
Volex (Asia) Pte Ltd MP5005
H05VV-F
VAC17S
VAC17S
10A/250V
0.75mm
0.75mm
2
x2
10A/250V
BS1363
BS6500
IEC60320
BS6500
IEC60320
ASTA
alt.
Well Shin Enterprise
Co. Ltd.
Co. Ltd.
WS-012A
H05VV-F
WS-002E
H05VV-F
WS-002E
13A/250V
0.75mm
0.75mm
2
x2
10A/250V
BS1363
BS6500
IEC60320
BS6500
IEC60320
BSI
Appliance inlet
Rich Bay Co., Ltd. R-301(21)
10A/250V
IEC60320 VDE
Socket-outlet
(OL91)
(OL91)
Dae Ryung Elect.
A3-02-D006
2.5A/250V ~
IEC60884-1
NEMKO
Mains switch
(SW1)
(SW1)
POSTEC Electric.
SDL1P-B
5A/80A 250V
IEC60065
IEC61058-1
VDE
Mains relay
(RY94)
(RY94)
Tyco Electronics
SDT-S-112DMR 8A/120A 250V
IEC60065
IEC 61058-1
IEC 61058-1
SEMKO
Mains fuse
(F901)
alt.
alt.
(F901)
alt.
alt.
Orisel Co. Ltd.
Littelfuse.
SUN Electronics
Walter Electronic.
Littelfuse.
SUN Electronics
Walter Electronic.
50T
218
218
06.3
5T
TSD
TSD
T6.3A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
1
) an asterisk indicates a mark which assures the agreed level of surveillance
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 7.Edition
- Page 30 of 32 -
www.nemko.com
Report No. 79765
TRF No: IEC/EN 60065F
14
TABLE: list of critical components and materials-continued
P
Component
Manufacturer/
trademark
Type/model
Value / rating
Standard
Approval/
Reference
Outlet fuse
(F902)
alt.
alt.
(F902)
alt.
alt.
Littelfuse B.V.
Bel Fuse.
Save Fusetech.
Wickmann-Werke.
Bel Fuse.
Save Fusetech.
Wickmann-Werke.
0663
MRT
SR-5
TR5 382
MRT
SR-5
TR5 382
T2.5A L 250V
IEC60127
VDE
VDE
VDE
VDE
VDE
VDE
VDE
Relay across
the cap (C904)
alt.
alt.
alt.
the cap (C904)
alt.
alt.
alt.
Du San Industrial.
Netron Tech.
Sam Wha Cap.
Murata Mfg.
Jyh Chung Elect.
Netron Tech.
Sam Wha Cap.
Murata Mfg.
Jyh Chung Elect.
NU
AA
SC
KH
JY
AA
SC
KH
JY
0.0047uF/250V,
X1.
X1.
IEC
60384-14,
2
nd
ed.
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
FIMKO
Body, top cover
Front panel
alt.
Display window
alt.
Front panel
alt.
Display window
alt.
Various
Kumho Chemical
LG Chemical
Mitsubishi Rayon
Mitsubishi Rayon
Kumho Chemical
LG Chemical
Mitsubishi Rayon
Mitsubishi Rayon
Various
HFA-452
AF-308
L530
MR100
HFA-452
AF-308
L530
MR100
Sheet Steel,
Min. 0.80 mm
ABS, V-2,
Min. 2.0 mm
PMMA, 94HB
Min. 2.0 mm
Min. 0.80 mm
ABS, V-2,
Min. 2.0 mm
PMMA, 94HB
Min. 2.0 mm
-
UL94
UL94
UL94
UL94
UL94
UL94
UL94
UL94
1.)
UL, E65424
UL, E67171
UL, E54695
UL, E54695
UL, E65424
UL, E67171
UL, E54695
UL, E54695
PCB base Mtl.
alt.
alt.
Top Faith PCB
Various
Various
TF-03
Various
Various
V-1, 130
°C
Min. V-1, 130
°C
UL 796
UL 796
UL 796
UL, E154636
UL
UL
DC B/less Fan
(Two peices provided)
Colorful Industrial
CF-12625MS
12V, 0.14A,
26CFM
IEC60950 TUV
1
) an asterisk indicates a mark which assures the agreed level of surveillance
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 7.Edition
- Page 31 of 32 -
www.nemko.com
Report No. 79765
TRF No: IEC/EN 60065F
ZB
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS
2.6.1
DK: certain types of Class I apparatus, see 15.1.1,
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
may be provided with a plug not establishing
earthing continuity when inserted in Danish socket-
outlets
Class II apparatus
N
13.3.1
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
Class II apparatus
N
15.1.1
DK: mains cord for single-phase equipment having
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
a rated current not exceeding 10 A shall be
provided with a plug according to Heavy Current
Regulations Section 107-2-D1
P
DK: Class I equipment with socket-outlets with
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
earthing contact, or which are intended to be used
in locations where protection against indirect
contact is required shall be provided with a plug in
compliance with Standard Sheet DK 2-1a
Class II apparatus
N
DK: socket-outlets for providing power to Class II
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
equipment with a rated current of 2,5 A shall have
dimensions according to the drawing on page 131
of EN 60 065:98 other dimensions shall be to
IEC 60 083 Standard Sheet C 1a for portable
socket-outlets
P
DK: mains socket-outlets with earthing contact
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
shall comply with Heavy Current Regulations
Section 107-2-D1, Standard Sheet DK 1-3a,
DK 1-5a or DK 1-7a
Class II apparatus.
N
GB: equipment fitted with a flexible cable or cord
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
provided with a 13A BS 1363 plug as in Statutory
Instrument 1768:94
BSI approved plug and cord
provided
provided
P
IE: equipment fitted with a flexible cable or cord
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
provided with a 13 A plug in accordance with
Statutory Instrument 525:97
When marketing in Ireland,
the apparatus must be supplie
d with a cord and plug
acceptable in Ireland.
the apparatus must be supplie
d with a cord and plug
acceptable in Ireland.
P
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the
following amendments:
following amendments:
P
- dimensions 2,5 A, 250 V socket-outlets shall
comply with Standard Sheet 1 page 132 of
EN 60 065:98
comply with Standard Sheet 1 page 132 of
EN 60 065:98
Comply
P
- mechanical strength 2,5 A, 250 V socket-outlets
tested as specified in EN 60 065, 12.1.3
tested as specified in EN 60 065, 12.1.3
Comply
P
- protecting rim also tested
Class II apparatus
N
- Page 32 of 32 -
www.nemko.com
Report No. 79765
TRF No: IEC/EN 60065F
NO: method b) of 8.1 is not permitted. Double or
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
reinforced insulation is required between parts
connected to the mains and parts connected to the
public telecommunications network
No TNV circuits
N
J.2
NO: In Norway, due to IT power distribution system
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
used, the a.c. MAINS supply voltage is considered
to be equal to the line-to-line voltage, and will
remain 230V in case of a single earth fault.
Class II apparatus.
N
ZC
ANNEX ZC TO EN 60 065, A-DEVIATIONS
5
DE: additional markings required in German language:
- cathode ray tubes with an accelerating voltage
between 20 kV and 30 kV (marking on the tube)
between 20 kV and 30 kV (marking on the tube)
No CRT in the equipment
N
- TV receivers whose picture tube has an
accelerating voltage between 20 kV and 30 kV
accelerating voltage between 20 kV and 30 kV
N
- TV receivers whose picture tube has an
accelerating voltage greater than 30 kV
accelerating voltage greater than 30 kV
N
- TV receivers whose picture tube has an
accelerating voltage less than 20 kV
accelerating voltage less than 20 kV
N
5.1
IT: additional markings on the outside of the TV
receiver in Italian language
receiver in Italian language
N
IT: user instructions in Italian language including a
conformity declaration
conformity declaration
N
IT: certification number on the back cover
N
14
SE: Switches containing mercury such as
thermostats, relays and level controllers are not
allowed.
thermostats, relays and level controllers are not
allowed.
No switches containing
mercury
mercury
N
Click on the first or last page to see other AVR 345 service manuals if exist.