- Page 29 of 32 - 
 
 
www.nemko.com
 
Report No.  79765 
 
TRF No:  IEC/EN 60065F 
 
 
14 
TABLE: list of critical components and materials 
 
Component 
Manufacturer/ 
trademark 
Type/model 
Value / rating 
Standard 
Approval/ 
Reference 
Main 
transformer 
 
Bobbin Mtl. 
Thermal fuse 
Seoul Electronics 
& Telecom Co Ltd. 
 
Wintech Polymer 
Therm-O-Disc. 
KLT5W027ZE 
CLT5W027ZE 
 
CN9030 
E4A51167C 
230V, Class B 
 
 
PET, V-0, 155
°C 
10A/250V, 167
°C
IEC60065 
clause 14.3 
 
UL94 
IEC60691 
1.) 
 
 
UL, E213445
VDE 
Sub  
transformer 
 
Bobbin Mtl. 
Thermal fuse 
Seoul Electronics 
& Telecom Co Ltd. 
 
LG Chemical Ltd.. 
Anzen Dengu Co 
KLT5J038ZE 
CLT5J038ZE 
 
GP2306F(#) 
K11 
230V Class E 
 
 
PBT, V-0, 140°C 
1A/250V, 115°C
 
IEC60065 
clause 14.3 
 
UL94 
IEC60691 
1.) 
 
 
UL E67171 
VDE 
Mains Cord Set 
(For CENELEC) 
Volex (Asia) Pte Ltd  M3204 
H05VV-F 
VAC17S 
10/16A, 250V 
0.75mm
2
 x2 
10A/250V 
IEC60884-1 
IEC60227 
IEC60320 
VDE 
alt. 
HWAJIN KDK Co. 
KKP-4819D 
H05VV-F 
KKS-16A 
10/16A, 250V 
0.75mm
2
 x2 
10A/250V 
IEC60884-1 
IEC60227 
IEC60320 
VDE 
Mains Cord Set 
(For UK and 
Singapore) 
Volex (Asia) Pte Ltd  MP5004 
MP5004A 
H05VV-F 
VAC17S 
13A/250V 
 
0.75mm
2
 x2 
10A/250V 
BS1363 
SS145 
BS6500 
IEC60320 
ASTA, PSB 
ASTA, PSB 
ASTA 
VDE 
Mains Cord Set 
(For UK)  
Volex (Asia) Pte Ltd  MP5005 
H05VV-F 
VAC17S 
10A/250V 
0.75mm
2
 x2 
10A/250V 
BS1363 
BS6500 
IEC60320 
ASTA 
 
alt. 
Well Shin Enterprise 
Co. Ltd. 
WS-012A 
H05VV-F 
WS-002E 
13A/250V 
0.75mm
2
 x2 
10A/250V 
BS1363 
BS6500 
IEC60320 
BSI 
Appliance inlet 
Rich Bay Co., Ltd. R-301(21) 
10A/250V 
IEC60320  VDE 
Socket-outlet 
(OL91) 
Dae Ryung Elect. 
 
A3-02-D006 
2.5A/250V ~ 
IEC60884-1 
NEMKO  
Mains switch 
(SW1) 
POSTEC Electric. 
SDL1P-B 
5A/80A 250V 
IEC60065
 
IEC61058-1
 
VDE 
Mains relay 
(RY94) 
Tyco Electronics 
SDT-S-112DMR 8A/120A 250V 
IEC60065 
IEC 61058-1 
SEMKO 
Mains fuse 
(F901) 
alt. 
alt. 
Orisel Co. Ltd. 
Littelfuse. 
SUN Electronics 
Walter Electronic. 
50T 
218 
06.3
 
5T 
TSD 
T6.3A L 250V 
IEC60127 
VDE 
VDE 
VDE 
VDE 
1
) an asterisk indicates a mark which assures the agreed level of surveillance 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 7.Edition 
 
 
- Page 30 of 32 - 
 
 
www.nemko.com
 
Report No.  79765 
 
TRF No:  IEC/EN 60065F 
 
 
14 
TABLE: list of critical components and materials-continued 
 
Component 
Manufacturer/ 
trademark 
Type/model 
Value / rating 
Standard 
Approval/ 
Reference 
Outlet fuse 
(F902) 
alt. 
alt. 
Littelfuse B.V. 
Bel Fuse. 
Save Fusetech. 
Wickmann-Werke. 
0663 
MRT 
SR-5 
TR5 382 
T2.5A L 250V 
IEC60127 
VDE 
VDE 
VDE 
VDE 
Relay across 
the cap (C904) 
alt. 
alt. 
alt. 
Du San Industrial. 
Netron Tech. 
Sam Wha Cap. 
Murata Mfg. 
Jyh Chung Elect. 
NU 
AA 
SC 
KH 
JY 
0.0047uF/250V, 
X1. 
IEC
60384-14, 
2
nd
 ed. 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
FIMKO 
Body, top cover 
 
 
Front panel 
alt. 
 
Display window 
alt. 
Various 
 
 
Kumho Chemical 
LG Chemical 
 
Mitsubishi Rayon 
Mitsubishi Rayon 
Various 
 
 
HFA-452 
AF-308 
 
L530 
MR100 
Sheet Steel,  
Min. 0.80 mm 
 
ABS, V-2,  
Min. 2.0 mm 
 
PMMA, 94HB 
Min. 2.0 mm 

 
 
UL94 
UL94 
 
UL94 
UL94 
1.) 
 
 
UL, E65424 
UL, E67171 
 
UL, E54695 
UL, E54695 
PCB base Mtl. 
alt. 
Top Faith PCB 
Various 
TF-03 
Various 
V-1, 130
°C 
Min. V-1, 130
°C 
UL 796 
UL 796 
UL, E154636
UL 
DC B/less Fan 
(Two peices provided)
 
Colorful Industrial 
CF-12625MS 
12V, 0.14A, 
26CFM
IEC60950 TUV 
 
 
 
 
 
 
1
) an asterisk indicates a mark which assures the agreed level of surveillance 
1.) Tested as part of the Apparatus according to EN 60 065 / IEC 60065, 7.Edition 
 
 
- Page 31 of 32 - 
 
 
www.nemko.com
 
Report No.  79765 
 
TRF No:  IEC/EN 60065F 
 
 
 
ZB 
ANNEX ZB TO EN 60 065, SPECIAL NATIONAL CONDITIONS 
 
2.6.1 
DK: certain types of Class I apparatus, see 15.1.1, 
may be provided with a plug not establishing 
earthing continuity when inserted in Danish socket-
outlets 
Class II apparatus 
13.3.1 
NO: In Norway, due to IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230V in case of a single earth fault. 
Class II apparatus 
15.1.1 
DK: mains cord for single-phase equipment having 
a rated current not exceeding 10 A shall be 
provided with a plug according to Heavy Current 
Regulations Section 107-2-D1 
 
 
DK: Class I equipment with socket-outlets with 
earthing contact, or which are intended to be used 
in locations where protection against indirect 
contact is required shall be provided with a plug in 
compliance with Standard Sheet DK 2-1a 
Class II apparatus 
 
DK: socket-outlets for providing power to Class II 
equipment with a  rated current of 2,5 A shall have 
dimensions according to the drawing on page 131 
of EN 60 065:98 other dimensions shall be to 
IEC 60 083 Standard Sheet C 1a for portable 
socket-outlets 
 
 
DK: mains socket-outlets with earthing contact 
shall comply with Heavy Current Regulations 
Section 107-2-D1, Standard Sheet DK 1-3a, 
DK 1-5a or DK 1-7a 
Class II apparatus. 
 
GB: equipment fitted with a flexible cable or cord 
provided with a 13A BS 1363 plug as in Statutory 
Instrument 1768:94 
BSI approved plug and cord 
provided 
 
IE: equipment fitted with a flexible cable or cord 
provided with a 13 A plug in accordance with 
Statutory Instrument 525:97 
When marketing in Ireland,  
the apparatus must be supplie
d with a cord and plug  
acceptable in Ireland. 
 
NO: mains socket-outlets on Class II equipment meet CEE Publication 7 with the 
following amendments: 
 
- dimensions 2,5 A, 250 V socket-outlets shall 
comply with Standard Sheet 1 page 132 of 
EN 60 065:98 
Comply 
 
- mechanical strength 2,5 A, 250 V socket-outlets 
tested as specified in EN 60 065, 12.1.3 
Comply 
 
- protecting rim also tested 
Class II apparatus 
 
 
- Page 32 of 32 - 
 
 
www.nemko.com
 
Report No.  79765 
 
TRF No:  IEC/EN 60065F 
 
 
 
 
NO: method b) of 8.1 is not permitted. Double or 
reinforced insulation is required between parts 
connected to the mains and parts connected to the 
public telecommunications network 
No TNV circuits 
J.2 
NO: In Norway, due to IT power distribution system 
used, the a.c. MAINS supply voltage is considered 
to be equal to the line-to-line voltage, and will 
remain 230V in case of a single earth fault. 
Class II apparatus. 
 
ZC 
ANNEX ZC TO EN 60 065, A-DEVIATIONS 
 
DE: additional markings required in German language: 
 
 
- cathode ray tubes with an accelerating voltage 
between 20 kV and 30 kV (marking on the tube) 
No CRT in the equipment 
 
- TV receivers whose picture tube has an 
accelerating voltage between 20 kV and 30 kV 
 
 
- TV receivers whose picture tube has an 
accelerating voltage greater than 30 kV 
 
 
- TV receivers whose picture tube has an 
accelerating voltage less than 20 kV 
 
5.1 
IT: additional markings on the outside of the TV 
receiver in Italian language 
 
 
IT: user instructions in Italian language including a 
conformity declaration 
 
 
IT: certification number on the back cover 
 
14 
SE: Switches containing mercury such as 
thermostats, relays and level controllers are not 
allowed. 
No switches containing 